OUTPUTS
Alarm output Relay: 250V AC, 8A (for resistive load), NO+NC
Mechanical 30.000.000 ; Electrical 100.000 operation.
Life expectancy for relay
0 ... +50°C/-25 ... 70°C
HOUSING
Housing type Suitable for flush-panel mounting. (According to DIN 43 700)
Dimensions W xH xD7 mm77 35 1
Weight
Enclosure material Self extinguishing plastics.
ENDA EPV 41 AC/DC VOLTMETER2 A
While cleaning the device, solvents (thinner, benzine, acid etc.) or must not be used.corrosive materials
Approx. 350g (after packing)
* 77 x 3 mm sized.
* 3 digits display.
*
* Easy to front panel keypad.
* Multifunctional alarm output (NO+NC) for upper and lower
* Measuring type can be selected AC, DC or True RMS.
5
configure with
limits.
* With insulated rs485 ModBus protocol communication
feature.(optional)
Values between -100V and 100 V can be indicated with one
decimal point.
* For maximum 50V AC/DC measurements;10 times the
sensitivity of the measurement values between -50V and +50V
with two decimal places to show.
Supply 230V AC +10% -20%, 50/60Hz or 24V AC 10% , 50/60Hz or optional 9-30V DC / 7-24V AC 10% SMPS± ±
Power consumption 2.5mm² screw-terminal connections
Wiring
Scale
Sensitivity
ELECTRICAL CHARACTERISTICS
If ; is selected,it isC.InP 500 0V...500V or If C.inP ;50 is selected,it is 0....50V
If ; is selected, it is -500V DC....500V DC or If ; is selected,it is -50V DC....50V DCC.InP 500 C.InP 50
0,01V (If ;50 is selected )C.InP
Max. 5VA
AC and RMS
DC
1. / 4 EPV 41 -E-100520192 A
±
Accuracy
EMC
Safety requirements
EN 61326-1: 2006
EN 61010-1: 20 (Pollution degree 2, overvoltage category II)10
1%
AC
RMS
DC ±1%
1%
(Full scale) (For square wave form 2%)±
(Full scale)
Input Impedance 870kΩ
Frequency Range
Input Range -500V...500V (If is selected,device breaks down at more than 1250 DC voltages.)
....50V ( is selected,device breaks down at more than 125 DC voltages.)
CINP 500
If cInp 50
±
-50V ±
±(Full scale) (For square wave form 2%)±
DC , 10Hz - 200Hz (For square wave form 10Hz-70Hz)
Thank you for choosing ENDA EPV 41 AC/DC voltmeter.2
Read this document carefully before using this device. The guarantee will be expired by
device damages if you don't attend to the directions in the user manual. Also we don't
accept any compensations for personal injury, material damage or capital disadvantages.
Technical Specifications
.Do not use the device in locations subject to corrosive and flammable gases
ENVIRONMENTAL CONDITIONS
Ambient/stroge temperature
Max. Relative humidity
Rated pollution degree
Height
Relative humidity for temperatures to relative humidity80% up to 31°C decreasing linearly 50% at 40°C.
According to EN 60529 Front panel : IP6 , Rear panel :5 IP20
Max. 2000m
0,1V (If is selected and higher than -100V or lower than 100V for input values)CINP;500
1V ( )If is selected and lower than -100V or higher than 100V for input valuesCINP 500;
1-Output
R......Relay
None...No relay
2 Supply Voltage- 3-ModBus
230VAC...230V AC
24VAC.....24V AC
SM...........9-30V DC / 7-24V AC
RSI..... Insulated ModBus (optional)
110VAC...110V AC
SETSET
EPV 241A
ENDA
OUT AC DC ACDC
V
Order Code : EPV241A- - -
23
1
E-mail : info@suran-elektronik.de
Internet : www.suran-elektronik.de
Tel.: +49 (0)7451 / 625 617
Fax: +49 (0)7451 / 625 0650
SURAN Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
english