turbofan E85HLD User manual

E85HLD PROVER
/ HOLDING CABINET
INSTALLATION / OPERATION
MANUAL
F22791-8

MANUFACTURED BY
Moffat Limited
PO Box 10001
Christchurch
New Zealand
Ph: (03) 389 1007
Fax: (03) 389 1276
WORLD-WIDE BRANCHES
UNITED KINGDOM
Blue Seal
Units 6-7, Mount Street Business Park
Mount Street, Nechells
Birmingham B7 5QU
Ph: (121) 327 5575
Fax: (121) 327 9711
UNITED STATES
Moffat Inc
3765 Champion Blvd
Winston-Salem
North Carolina 27115
Ph: (336) 661 0257
Fax: (336) 661 9546
CANADA
Serve Canada
22 Ashwarren Road
Downview
Ontario M3J1Z5
Toll Free:800 263 1455
Ph: (416) 631 0601
Fax: (416) 631 0315
www.servecanada.com
www.moffat.com
NEW ZEALAND
Christchurch Auckland
Moffat Limited Moffat Limited
PO Box 10-001 4 Waipuna Road
16 Osborne Street Mt Wellington
Christchurch Auckland
Ph: (03) 389 1007 Ph: (09) 574 3150
Fax: (03) 389 1276 Fax: (09) 574 3159
AUSTRALIA
Victoria New South Wales
Moffat Pty Limited Moffat Pty Limited
740 Springvale Road 3/142 James Ruse Drive, Rose Hill
Mulgrave, Melbourne PO Box 913, Smithfield
Victoria 3171 Sydney, N.S.W. 2142
Ph: (03) 9518 3888 Ph: (02) 8833 4111
Fax: (03) 9518 3838 Fax: (02) 8833 4133
Western Australia Queensland
Moffat Pty Limited Moffat Pty Limited
67 Howe Street 30 Prosperity Place
Osbourne Park Geebung, Brisbane
WA 6017 Queensland 4034
Ph: (08) 9202 6820 Ph: (07) 3630 8600
Fax: (08) 9202 6836 Fax (07) 3630 8623
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously in
writing by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and
design without prior notice.
© Copyright Moffat Ltd. November 2006.

Introduction ........................................................................................................2
Installation ..........................................................................................................3
Before Connection
Location
Electrical Connection
Water Connection (Auto Fill Models Only)
Rack Width
Stacking with Convection Oven
Specifications.....................................................................................................5
Operation............................................................................................................9
Description of Controls
Condensation Channel
Operating in PROVE Mode
Bake-Off
Problem Solving
Hints
Operating in HOLD Mode
Cleaning and Maintenance..............................................................................13
Trouble Shooting .............................................................................................14
Spare Parts.......................................................................................................15
Circuit Schematics...........................................................................................16
E85-HLD Prover / Holding Cabinet (Manual Fill)
E85A-HLD Prover / Holding Cabinet (Auto Fill)
Date Purchased................................................................. Serial No ..........................................................
Dealer............................................................................................................................................................
Service Agent ................................................................................................................................................
Contents
1

We are confident that you will be delighted with your E85HLD PROVER / HOLDING CABINET, and it will
become a most valued appliance in your commercial kitchen.
A new oven can seem very complex and confusing at first glance. To ensure you receive the utmost
benefit from your new Prover, there are two important things you can do.
Firstly
Please read the instruction book carefully and follow the directions given. The time taken will be well
spent.
Secondly
If you are unsure of any aspect of the installation, instructions or performance of your prover, contact your
E85HLD dealer promptly. In many cases a phone call could answer your question.
Introduction
2

Before Connection to Power Supply
• Remove all packing.
• Check equipment and parts for damage. Report any damage immediately to the carrier and
distributor.
• Remove protective plastic coating from the side panels.
• Check that the available power supply is correct to that shown on the rating plate located on the
right-hand side panel.
E85HLD 110-120 Volts A.C, 60 Hz, 1P+N+E, 1.65 kW, 14.5 A
E85HLD 220-240 Volts A.C, 50 Hz, 1P+N+E, 1.65 kW, 7.2 A
Location
• To ensure correct ventilation for the motor and controls the following minimum installation
clearances are to be adhered to:
Electrical Connection
• E85HLD provers are supplied fitted with cords. Ensure unit is fitted with correct cord and plug.
• To access the electrical connection terminal block, grounding lug and strain relief, remove the
right hand side panel.
WARNING - THIS APPLIANCE MUST BE EARTHED / GROUNDED
Water Connection (Auto Fill Models Only)
• A cold water supply should be fitted to the water inlet (¾” BSP connection) which is located near
the rear of the right hand side of the unit.
• Alternately, a connection elbow and sealing washer is supplied with this unit for direct connection
of a ½” ID hose, and is recommended for easy installation and service.
• Connect water supply - Max inlet pressure 80psi / 550kPa.
• Turn on water supply to check for leaks.
Rack Width
• The E85HLD prover has been designed to accept either 18”
or 16” wide trays.
• The prover comes factory set for 18” trays, to change to 16”
trays:
• Remove the RH side rack (lift and extract).
• Undo the thumb screws (A) holding the RH rack
supports (B) and turn RH rack supports around, then
re-secure with thumbscrew.
3
Installation
Installation Requirements
It is most important that this prover / holding cabinet is installed correctly and that
operation is correct before use.
Installation shall comply with local electrical, health and safety requirements.
Rear 0 mm / 0 ”
Left-hand side 0 mm / 0 ”
Right-hand side 25 mm / 1 ”
A
A
A
A
B
B
B
B
For 18” trays For 16” trays

Stacking with Convection Oven
• The E85HLD prover is supplied standard with a top lid for stand alone use.
• Optionally, the E85HLD prover can be combined underneath a MOFFAT E35 convection oven as
a complete unit. For this a stacking kit is required (part number 022299).
• For installation of the stacking kit, refer to the instructions provided with the kit. These instructions
also include the procedure for mounting the E35 convection oven on top of the E85HLD prover
and stacking kit.
Installation
4

250
150
902
880
ELECTRICAL ENTRY
WATER ENTRY
MWS
E
1
880
MWS
E
1
MWS
40
E
1
5
Specifications
Electrical Connection 110-120 Volts A.C, 60 Hz, 1P+N+E, 1.65 kW, 14.5 A
220-240 Volts A.C, 60Hz, 1P+N+E, 1.65kW, 7.2A
Cold Water Connection
(Auto Fill Models Only)
¾” B.S.P. or 1/2ID hose (550kPa / 80psi maximum pressure)
E85-8HLD Prover
Side
Front
Plan

250
150
1145
WATER ENTRY
ELECTRICAL ENTRY
E
1
MWS
880
E
1
MWS
880
40
E
1
6
Specifications
E85-12HLD Prover
Electrical Connection 110-120 Volts A.C, 60 Hz, 1P+N+E, 1.65 kW, 14.5 A
Cold Water Connection
(Auto Fill Models Only)
¾” B.S.P. or 1/2ID hose (550kPa / 80psi maximum pressure)
Side
Front
Plan

E
3
40
MWS
880 (26" Ovens)
800
980 (30" Ovens)
E
1
880
E
3
MWS
1006.5 100
WATER ENTRY
ELECTRICAL ENTRY
3E
MWS
ELECTRICAL ENTRY
150
E
1
1753
902
7
Specifications
E85-8HLD Prover / E35 Oven
Side
Front
Plan

E
3MWS
40
E
1
880
E
3
MWS
1001250
ELECTRICAL ENTRY
WATER ENTRY
3E
MWS
150
E
1
ELECTRICAL ENTRY
1145
2000
880 (26" Ovens)
800
980 (30" Ovens)
8
Specifications
E85-12HLD Prover / E35 Oven
Side
Front
Plan
This manual suits for next models
2
Table of contents
Popular Kitchen Appliance manuals by other brands

Tayama
Tayama TYG-35AF instruction manual

AEG
AEG 43172V-MN user manual

REBER
REBER Professional 40 Use and maintenance

North American
North American BB12482G / TR-F-04-B-NCT-1 Assembly and operating instructions

Presto
Presto fountain popper instruction manual

Westmark
Westmark 1035 2260 operating instructions