Integrating Sound Level Meter / EN
08/15/16 Version No. 01 6
RANGE: 60 – 120 dB. Test starting point 94 dB for all weightings and frequencies except
31.5Hz A-weighted, for which the starting point is 74 dB.
FREQUENCY
Hz WEIGHTING
L.O.R.
dB WEIGHTING
L.O.R.
dB
31.5 A 60.0 – 80.6 C 60.0 – 117.0
1000 A 60.0 – 120.0 C 60.0 – 120.0
4000 A 60.0 – 120.0 C 60.0 – 119.2
8000 A 60.0 – 118.9 C 60.0 – 117.0
RANGE: 70 – 130 dB. Test starting point 104 dB for all weightings and frequencies
except 31.5Hz A-weighted, for which the starting point is 84 dB.
FREQUENCY
Hz WEIGHTING
L.O.R.
dB WEIGHTING L.O.R.
dB
31.5 A 70.0 – 90.6 C 70.0 – 127.0
1000 A 70.0 – 130.0
C 70.0 – 130.0
4000 A 70.0 – 130.0
C 70.0 – 129.2
8000 A 70.0 – 128.9
C 70.0 – 127.0
Frequency range:
Overall characteristics including microphone: 31.5 to 8000Hz
Frequency weighting: A,meets the requirement of IEC 61672-1 for class 2
“A” weighting.
C,meets the requirement of IEC 61672-1 for class 2
“C” weighting.
Time weighting (RMS detection): Fast, according to IEC 61672-1 class 2.
Slow, according to IEC 61672-1 class 2.
Impulse, according to IEC 61672-1 class 2.
•
Reference conditions:
Type of the acoustic field: Free
Reference sound pressure level: 94.0dB (related to 20µPa)
Reference level range: 60 to 120dB
Reference frequency: 1000Hz
Reference temperature: +23°C
Reference relative humidity: 50%RH
Reference static pressure: 101.325 kPa
Reference incidence direction: Perpendicular to the front of the microphone
diaphragm.
•
Calibration: Acoustic using calibrator SLC 1356, B&K 4231 or equivalent.
Calibration check frequency is 1000Hz.
Nominal calibration level for the free field: 94.1dB
Nominal calibration level for the diffuse field:94.0dB