Rinstrum 400 Series User manual

400 Series
(K410)
Batching Indicator
Operator Manual
004R-614-120

Copyright
All Rights Reserved. No part of this document may be
copied, reproduced, republished, uploaded, posted,
transmitted, distributed, stored in or introduced into a
retrieval system in any form, or by any means (electronic,
mechanical, photocopying, recording or otherwise)
whatsoever without prior written permission of Rinstrum
Pty Ltd.
Disclaimer
Rinstrum Pty Ltd reserves the right to make changes to
the products contained in this manual in order to improve
design,
performance or reliability.
The information in this manual is believed to be accurate
in all respects at the time of publication, but is subject to
change without notice. Rinstrum Pty Ltd assumes no
responsibility for any errors or omissions and disclaims
responsibility for any consequences resulting from the use
of the information provided herein.

Operator Manual - Software Version 1.x & 2.x
004R-614-120 Page 1
Table of Contents
1. INTRODUCTION..........................................................................3
2. SAFETY .......................................................................................4
2.1. Operating Environment...........................................................4
2.2. Electrical Safety ......................................................................4
2.3. Cleaning..................................................................................4
3. BASIC OPERATION....................................................................5
3.1. User Interface Display and Controls .......................................5
3.2. Display ....................................................................................6
3.3. Annunciators...........................................................................7
3.4. Keypad....................................................................................8
3.5. Basic Operation ......................................................................9
Power Key....................................................................................9
Zero Key.......................................................................................9
Tare Key.....................................................................................10
Recipe Key.................................................................................10
3.6. Stability Considerations ........................................................11
3.7. Security.................................................................................11
4. ADDITIONAL FUNCTIONS .......................................................12
4.1. System Time and Date (Clock - 1 key) .................................12
4.2. Display View (View – 2 key) .................................................12
4.3. Reports (Report - 3 key) .......................................................13
4.4. Totals (Total - 4 key).............................................................13
4.5. ID Names (ID – 5 key) ..........................................................14
4.6. Pulse Timers (Timers – 6 key)..............................................14
4.7. Set Point Targets (Target – key 7)........................................15
4.8. Flight Settings (Flight – key 8) ..............................................15
4.9. Tolerance (Tol – key 9).........................................................16
4.10.Lock ......................................................................................16
4.11.Alibi .......................................................................................17
Switching to Alibi Mode ..............................................................17
Returning from Alibi Mode..........................................................17
4.12.Accessory Modules (Acc – 0 key).........................................17
4.13.Product Selection (v2.x software Only).................................18
4.14.Add Product (v2.x software Only) .........................................18
4.15.Delete Product (v2.x software Only) .....................................19

Operator Manual - Software Version 1.x & 2.x
Page 2 004R-614-120
4.16.Rename Product (v2.x software Only)..................................19
5. FUNCTION KEYS......................................................................20
Overview ....................................................................................20
Print, Report Key........................................................................20
Single Key ..................................................................................20
Blanking Input ............................................................................20
Start............................................................................................20
Pause, Abort, PSE.ABT, SUSPND ............................................20
Test ............................................................................................21
6. ERROR MESSAGES.................................................................22
6.1. Weighing Errors ....................................................................22
6.2. Pause Conditions..................................................................23

Operator Manual - Software Version 1.x & 2.x
004R-614-120 Page 3
1.Introduction
This instrument is a precision digital indicator designed for
gain in weight batching applications. It supports up to 32
input/outputs.
It may be operated from either a DC power source (12VDC to
24VDC) or AC power (optional 110 – 240 VAC). There is a
soft power on/off function that retains memory of its state.
Once an instrument is turned on it will automatically start up
again if the external power is interrupted.
The indicator supports optical communications as a
standard which allows a temporary isolated communications
link to be established with a PC. Software upgrades, the
use of computerised setup and calibration can then be done
using a PC.

Operator Manual - Software Version 1.x & 2.x
Page 4 004R-614-120
2.Safety
2.1. Operating Environment
•Operating Temperature: –10 to 50°C
•Humidity: <90% non-condensing
•Operating Voltage: Shown on Rear Label
2.2. Electrical Safety
•For your protection all mains electrical hardware must be
rated to the environmental conditions of use.
•Pluggable equipment must be installed near an easily
accessible power socket outlet.
•To avoid the possibility of electric shock or damage to the
instrument, always switch off or isolate the instrument
from the power supply before maintenance is carried out.
2.3. Cleaning
•To maintain the instrument, never use harsh abrasive
cleaners or solvents. Wipe the instrument with a soft
cloth slightly dampened with warm soapy water.

Operator Manual - Software Version 1.x & 2.x
004R-614-120 Page 5
3.Basic Operation
3.1. User Interface Display and Controls
Code Description
1 Display
2 Opto-link connection point
3 Power Key
4 Function Keys (Fixed)
5 Function Keys (user defined)
6 Numeric Keypad

Operator Manual - Software Version 1.x & 2.x
Page 6 004R-614-120
3.2. Display
21
4
8
3
7
6
5
Code Description
1 Primary Annunciators
2 Primary Display
3 Auxiliary Display
4 Primary Units
5 Secondary ID
6 Miscellaneous Annunciators
7 Secondary Units
8 Secondary Display

Operator Manual - Software Version 1.x & 2.x
004R-614-120 Page 7
3.3. Annunciators
Primary Annunciators
HOLD Visible when the displayed reading is
held.
NET Visible when the displayed reading
represents Net weight.
ZERO Visible when the gross reading is within
±¼ of a division of true zero.
MOTION Visible when the displayed reading is
not stable.
ZERO
BAND
Visible when the displayed weight is
within the zero ‘dead’ band setting.
RANGE Indicates current range (for dual
range/interval).
Miscellaneous Annunciators
Rotating RUN - Batch running
Stationary
and
flashing
PAUSE - Batch paused
Lit Time Delay - Time annunciator lit while
a time delay is in progress at the start
or end of a stage.
Flashing WAIT - Time annunciator flashes when
the instrument is waiting for an input
during a WAIT stage.
Bars indicate Slow, Medium and Fast
speed filling in progress

Operator Manual - Software Version 1.x & 2.x
Page 8 004R-614-120
3.4. Keypad
Code Description
1 Numeric
Button
0-9
2 White
Characters
Additional Functions (Hold 2 seconds)
3 Orange
Characters
(Alpha and Symbols)
Cancel Undo last command; step backwards
(including in menus).
Up Move cursor backwards; previous option
Down Move cursor forwards; next option
OK Accept this choice
Decimal Point Place decimal point
+/- Change to negative or positive number;
access or exit Alibi
Other manuals for 400 Series
7
This manual suits for next models
1
Table of contents
Other Rinstrum Measuring Instrument manuals

Rinstrum
Rinstrum 400 Series User manual

Rinstrum
Rinstrum 5200 Instruction manual

Rinstrum
Rinstrum 400 Series User manual

Rinstrum
Rinstrum 400 Series Instruction manual

Rinstrum
Rinstrum R300 Series User manual

Rinstrum
Rinstrum C300 Series User manual

Rinstrum
Rinstrum 2100 Instruction manual

Rinstrum
Rinstrum 400 Series User manual

Rinstrum
Rinstrum M4201 User manual

Rinstrum
Rinstrum 5200 Use and care manual