Hyco Zen Spa Series Specification sheet

Product Instruction Manual
Zen Spa
2 in 1 Boiling and Chilled Tap
SPA3L, SPA6L, SPA3LUC1, SPA6LUC1
v19.12.1

Overview
Thank you for purchasing a Zen Spa 2 in 1 Boiling and Chilled Tap. The Zen Spa is a hot and
cold drinks station that provides boiling water and ltered cold (ambient) drinking water. If
desired an undersink chiller can be purchased to provide ltered chilled drinking water.
In the home it replaces the need for a kettle and provides high quality cold drinking water.
In the oce it replaces the need for a wall mounted boiling water unit and separate oor
standing chiller.
Key Features
• Energy ecient boiling water tank.
• Safety lock on the boiling side and a cool touch spout.
• 360° swivel spout.
• Pattern recognition technology to learn and predict boiling water usage.
• Supplied with initial high quality scale lter for the inlet to the boiling tank and a cold
drinking water lter.
• Two temperature settings 100°C and 98°C.
• Can be installed over a sink or with a stylish Zen Font.
• Designed and assembled in the UK.
Always switch o the mains electricity before commencing installation.
Only connect the unit to a single-phase supply as specied on the rating plate.
Ensure tank is full of water and tap ushed through before switching power on.
The supply cord cannot be replaced by the user. If the cord is damaged the
appliance should be returned to the manufacturer or an authorised service agent
for replacement.
The hoses and pipes supplying this heater must not come into contact with any
xed wiring or the supply cord.
Do not carry the appliance by the supply cord.
An RCD circuit breaker is strongly recommended.
This unit dispenses boiling water.
1. Important Safety Points
2

The boiling tank must be placed on a solid surface where it will not be knocked
over causing damage to the water hoses or electrical connections.
The boiling tank must not be used in an area subject to ammable vapours such
as paint, solvent or petrol.
This product is not suitable for outdoor use or in damp conditions.
Do not use in ambient temperatures exceeding 35°C.
Allow 20 mm space between the boiling tank and the walls for cooling air
circulation.
The pressure relief valve supplied with the unit must be tted.
The pressure relief valve must be tested regularly to remove scale deposits (see
maintenance section).
Water may drip from the pressure relief valve; this must be piped to drain as per
local relevant regulations.
This appliance can be used by children aged 12 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning the use
of the appliance in a safe way.
Children shall not play with the appliance.
Children shall not clean or maintain the appliance without supervision.
Before conducting any user maintenance, the product should be isolated from
the electrical supply and then the boiling side of the tap opened until the water
runs cold.
Do not modify or misuse the product in any way or serious injury could occur.
3

Box Contents
Expanssion vessel
Pressure relief valve
Manifold
Cold drinking water lter
Hose ‘manifold to exp vessel’ Hose ‘manifold to tank’
xing bracket and metal band
Scale lter
Hose ‘tank to tap’
Zen tankZen Spa tap
Expansion vessel
For Zen Spa with chiller (UC1 models) chiller sent separately.
4

2 x 1/2” female to 3/8”PF 2 x Black rubber washer 1 x Large and 3 x small white washer
1.5 m x 1/4” and 3/8” tubing 6 x Large locking collar and 5 x small
2 x 1/2” BSP to 15mm1 x 3-way 3/8”to 1/4”PF 1/4” x 1/4” PF
5

The tank must be sited vertically and on a at level surface.
The supplied scale lter must be tted and changed at least every 6 months,
otherwise the lifespan of the product could be seriously reduced and the
warranty may be void.
The supplied drinking water lter must be changed at least every 6 months.
A pressure reducing valve is required if the mains pressure is above 0.42 MPa (4.2
bar).
The Zen Spa is factory set at 100°C. The temperature can be switched down to
98°C should this be desired. Please see Section 6 for further instructions.
White washers are to facilitate water connections on hoses labelled ‘‘tank to tap’
and ‘manifold to tank’.
Black washers are to facilitate water connections on hose labelled ‘manifold to
exp vessel’.
Ensure that all hose connections are tightened using a suitable spanner.
Ensure that the tank, power socket, service valve and installation kit (manifold,
relief valve and expansion vessel) are positioned to allow future maintenance.
1. Installation
Important Installation Information
6

Diagram 1
7

• Choose a suitable location to mount the tap, this may be an existing hole in your sink
or countertop.
• If a new hole is required check that the reach of the spout will be appropriate for your
sink before drilling the tap hole in the sink or worktop. The required hole diameter is
32 mm - ts in a standard sink.
• If installing in a Zen Font with Drain use the template supplied with the Zen Font to
establish tap hole position.
• The tap can be installed onto sink/countertop up to 50 mm thick.
• Place tap into hole, ensure the black o-ring is above the worktop. See Diagram 2.
• Place the steel washer onto the threaded section of the tap under worktop/ sink.
• Lastly the brass locking nut will screw onto the same threaded section. This will
secure the tap in position.
Step 1 - Prepare and Site the Tap
8

Diagram 2
9

Step 2 - Prepare Manifold Connections
• It is imperative that no ttings, other than those specied in the instructions, are
installed within the ‘expansion zone’. This is everything beyond the check valve,
located within the manifold. See Diagram 3.
• Use Diagram 1 to establish suitable locations for each component which forms part
of the full installation. If you are installing a chiller, please see Diagram 4 in Section 2.
• Note the boiling tank must be located as close to the tap as practicable as it is not
possible to extend hoses provided.
• Attach ½”M BSP to 15 mm compression tting to otake 1, see Diagram 3, of the
manifold and tighten with spanner.
• Connect to desired length of copper pipe then connect to relief valve. This is a safety
device which must be tted and piped to drain via air gap before commissioning.
• From otake 3 of the manifold attach hose labelled‘manifold to exp vessel’using 1
black washer.
Diagram 3
10
This manual suits for next models
4
Table of contents
Popular Kitchen Appliance manuals by other brands

Tayama
Tayama TYG-35AF instruction manual

AEG
AEG 43172V-MN user manual

REBER
REBER Professional 40 Use and maintenance

North American
North American BB12482G / TR-F-04-B-NCT-1 Assembly and operating instructions

Presto
Presto fountain popper instruction manual

Westmark
Westmark 1035 2260 operating instructions