SOLTEK SL-85DRV+ User manual

Mainboard
Series SL-85DRV
User Manual V1.1
R
The Soul Of Computer Technology
SL-85DRV
SL-85DRV+
SL-85DRV-X
SL-85DRV+-X

Series SL-85DRV
2
his Users Guide & Technical Reference is to help system manu-
facturers and end-users set up and install the mainboard.
Every effort has been made to ensure that the information in this
manual is accurate. Soltek Computer nc. is not responsible for print-
ing or clerical errors. nformation in this document is subject to
change without notice and does not represent a commitment on
Soltek Computer nc.
No part of this manual may be reproduced, transmitted, translated
into any language in any form or by any means, electronic or
mechanical, including photocopying and recording, for any purpose
without the express written permission of Soltek Computer nc.
Companies and products mentioned in this manual are for identifi-
cation purpose only. Product names appearing in this manual may
or may not be registered trademarks or copyrights of their respec-
tive companies.
Soltek Computer nc. provides this manual “as is “ without warranty
of any kind, either express or implied, including but not limited to the
implied warranties or conditions of merchantability or fitness for a
particular purpose. n no event shall Soltek Computer nc. be liable
for any loss or profits, loss of business, loss of use or data, interruption of
business, or for indirect, special, incidental, or consequential damages of
any kind, even if Soltek Computer nc. has been advised of the possibility
of such damages arising from any defect or error in this manual or product.
Copyright © 2001 Soltek Computer In . All Rights Reserved.
NOTICE Product Model : Series SL-85DRV
Manual Revision : V1.1
Release Date : October 2 1
• ntel Pentium 4 and Northwood are trademarks of ntel Corporation.
• V A , V A Apollo P4X266 and VT8233 are trademarks of V A Technologies, nc.
mPGA478B
T

3
Series SL-85DRV
SOLTEK AROUND THE WORLD
SOLTEK COMPUTER INC.
Address : 7F, No. 306-3, Ta-Tung Rd, Sec.1, Hsi-Chih, Taipei-
Hsien, Taiwan, R.O.C.
Telephone : 886-2-2642-9060
Fax : 886-2-2642-9065
E-mail : [email protected]
Web site : http://www.soltek.com.tw
SOUL TECHNOLOGY EUROPE B.V.
Address : Hongkongstraat 55, 3047 BP Rotterdam. The Neth-
erlands
Telephone : 31-10-2457492
Fax : 31-10-2457493
E-mail : [email protected]
Web site : http://www.soultech-europe.com
SOLTEK KOREA INC.
Address : 1002, Chung Jin Bldg. 53-5 Wonhyo-Ro, 3-Ka,
Yongsan-Ku Seoul 140-113, Korea
Telephone : 82-2-32717400
Fax : 82-2-32717405
E-mail : [email protected]

Series SL-85DRV
CONTENT
ITEM CHECKU ............................................. 8
Chapter 1 Spe ifi ation .......................................................... 9
1-1 Mainboard Specifications ...................................................... 10
1-1.1 CPU Socket .................................................................................. 10
1-1.2 System Chipsets ........................................................................... 10
1-1.3 Memory ......................................................................................... 10
1-1.4 AWARD B OS V6.0 ....................................................................... 10
1-1.5 Accelerated Graphics Port (AGP) nterface .................................. 10
1-1.6 Advanced system Power Management, supporting: .................... 11
1-1.7 Multi- /O Functions: ....................................................................... 11
1-1.8 Expansion Slots ............................................................................ 11
1-1.9 Hardware Monitor on board .......................................................... 12
1-1.10 AC’97 Audio Codec on board ..................................................... 12
1-1.11 CNR Slot on board ..................................................................... 12
1-1.12 Disk RA D (Redundant Array of ndependent Disks) .................. 12
1-1.13 Voice Diagnostic Technology ...................................................... 12
1-1.14 Form Factor ................................................................................ 12
1-2 Series SL-85DRV -- Layout with Optional Features........... 13
1-3 Mainboard Specification Table .............................................. 14
1-4 Chipset System Block Diagram ............................................ 15
Chapter 2 Hardware Setup ................................................... 17
2-1 CPU Pentium 4 nstallation with Socket 478 ....................... 18
2-2 Pentium 4 CPU Fan nstallation:........................................... 19
2-3 Memory nstallation................................................................ 20
2-3.1 To nstall DDR SDRAM Module for this Series : ........................... 20
2-3.2 To Remove a D MM: ..................................................................... 21
2-3.3 ndicator ZD1 D MM Socket On: ................................................... 21
2-4 AGP 4X (Accelerated Graphics Port) Card nstallation : .. 22
2-5 HDD/FDD nstallation ............................................................ 23

Content
2-6 ATX V 2.03 Power Supply nstallation .................................. 25
2-7 Jumper and Switch Settings.................................................. 26
2-7.1 Switch 1 CPU Clock Select .......................................................... 27
2-7.2 JBAT1 Clear CMOS ..................................................................... 28
2-7.3 Jp12 RA D Controller Select: ....................................................... 28
2-7.4 Jp18 Voice Diagnostic Language Select...................................... 29
2-7.5 Jp16 Suspend to RAM (STR) ...................................................... 30
2-7.5 Jp11 Flash ROM Write Protection Select ...................................... 30
2-8 Other Connectors Configuration ........................................... 31
2-8.1 On Board FAN Connectors (FAN1,FAN2, FAN3) .......................... 31
2-8.2 WOL1 Wake On LAN .................................................................... 32
2-8.3 CD-ROM Audio Connector (CD_ N1/CD_ N2) .............................. 33
2-8.4 Chassis Panel Connector ............................................................ 33
2-8.5 Thermal Sensor Connector (RT2) ................................................. 34
2-8.6 Complex Header NJP1 ................................................................ 35
2-8.7 ATX Power Supply Connectors for Pentium 4 ............................ 37
2-8.8 Communication And Networking Riser Slot (CNR) ....................... 38
2-8.9 USB Ports and USB Headers (Header USB 2 & 3) ..................... 39
2-8.10 PS/2 Mouse And PS/2 Keyboard ................................................ 39
2-9 RQ Description ...................................................................... 40
Chapter 3 Software Setup .................................................... 42
3-1 Open up the Suport CD and choose Drivers and Utilities: . 43
3-2 Proceed to V A 4- N-1 Drivers nstallation .......................... 44
3-3 Proceed to AC’97 AUD O DR VER nstallation .................... 46
3-4 Proceed to HARDWARE MON TOR nstallation.................. 47
3-5 nstall Driver for Promise RA D Controller ........................... 49
Chapter 4 BIOS Setup ........................................................... 51
4-1 About B OS Setup .................................................................. 52
4-2 To run B OS Setup ................................................................. 52
4-3 About CMOS........................................................................... 52
4-4 The POST ( Power On Self Test ) ......................................... 52

Series SL-85DRV
4-6 B OS SETUP --- CMOS Setup Utility ................................... 57
4-6.1 CMOS Setup Utility ....................................................................... 57
4-6.2 Standard CMOS Setup ................................................................. 58
4-6.3 Advanced B OS Features ............................................................. 61
4-6.4 Advanced Chipset Features .......................................................... 65
4-6.5 ntegrated Peripherals................................................................... 70
4-6.6 Power Management Setup ........................................................... 76
4-6.7 PNP / PC Configuration ............................................................... 82
4-6.8 SmartDoc Anti-burn Shield (PC Health status) ............................. 85
4-6.9 Frequency/Voltage Control .......................................................... 87
4-6.10 Load Optimized Defaults............................................................ 89
4-6.12 SET SUPERV SOR / USER PASSWORD .................................. 90
4-6.13 SAVE & EX T SETUP ................................................................. 91
4-6.14 EX T W THOUT SAV NG ............................................................ 91
Chapter 5 RAID Controller................................................... 93
5-0 Before Creating Disk Array: ................................................. 94
5-1 Creating Your Disk Array ....................................................... 95
5-1.1 Creating An Array For Performance .............................................. 95
5-1.2 Creating A Security (Mirror) Array With New Drives ...................... 97
5-1.3 Creating Security Array With Existing Data Drive ......................... 99
5-2 Using FASTBU LDTM Configuration Utility ........................ 102
5-2.1 Viewing FastTrak100-Lite B OS Screen ..................................... 102
5-2.2 Navigating the FastBuildTM Setup Menu ................................... 103
5-2.3 Using the Main Menu .................................................................. 103
5-2.4 Creating Arrays Automatically ..................................................... 104
5-2.5 Viewing Drive Assignments ......................................................... 106
5-2.6 View an Array .............................................................................. 106
5-2.7 Adding Fault Tolerance to an Existing Drive ............................... 107
5-2.8 Making a FastTrak100-Lite Disk Array Bootable ......................... 108
5-2.9 Creating a “Hot” Spare Drive for Mirroring Arrays ....................... 109
4-5 To upgrade B OS.................................................................... 52
4-5.1 Before Upgrading B OS ................................................................ 52
4-5.2 Upgrade Process .......................................................................... 52

Content
5-2.10 How FastTrak100-Lite Orders Arrays ....................................... 110
5-2.11 How FastTrak100-Lite Saves Array nformation........................ 110
5-2.12 Deleting An Array ...................................................................... 110
5-2.13 Rebuilding A Mirroring Array ..................................................... 112
5-2.14 Viewing Controller Settings ....................................................... 114
5-2.15 Halting FastTrak B OS On Bootup Errors ................................. 114
5-3 nstalling Drivers .................................................................. 115
5-3.1 For Windows 2000 ...................................................................... 115
5-3.2 Windows 95/98 ........................................................................... 117
5-3.3 DOS/Windows 3.1x ..................................................................... 120
5-3.4 Windows NT4.0........................................................................... 121
APPENDICES ....................................................................... 124
Appendix-1 dentify B OS Version & B OS Part Number........ 125
Appendix-2 dentify Mainboard Model Number ....................... 126
Appendix-3 Technical Terms ...................................................... 127

8
Series SL-85DRV
Mainboard
Support CD
Floppy diskette (Optional RA D Drivers)
Bundled Bonus Pack CD
Bundled Bonus Pack Manual
Temperature Sensor Cable
ATA66/100 DE Cable
FDD Cable
User’s Manual
RS232 Cable
ITEM CHECKUP

9
Chapter 1 Specification
Chapter 1 Specification
This series of mainboards features an integration of the powerful pro-
cessor ntel Pentium 4 and the single-chip North Bridge V A P4X266.
The ntel P4 processor is a rapid execution engine providing 400MHz
quadpumped system bus to allow
3.2GB data transfer rates possible, while V A Apollo P4X266 North
Bridge plus VT8233 South Bridge support ntel P4 processor to ex-
ecute the 400MHz FSB, the AGP 4X external bus, the LPC Super /O
and the DDR SDRAM data transfer. This chapter is to introduce to
users every advanced function of this high performance integration.
Topi s in luded in this hapter are:
1-1 Mainboard Spe ifi ations
1-2 Mainboard Layout
1-3 Mainboard Spe ifi ation Table
1-4 Chipset Diagram
Introduction

1
Series SL-85DRV
1-1.1 CPU So ket
• CPU Socket 478B on board, supporting ntel® Pentium 4 and Northwood
processors in the 478-pin package for :
-- 400MHz System Bus;
-- Hyper pipelined technology;
-- Advanced dynamic execution;
-- Advanced transfer cache;
1-1.2 System Chipsets
• North Bridge VT8753 (P4X266) plus South Bridge VT8233 to work with
ntel Pentium 4 Processor for managing and arbitrating operations between
all system interfaces:
1-1.3 Memory
3 DDR D MM 184-pin sockets on board for PC2100/1600 DDR SDRAMs,
supported by 2.5V default voltage (D MM voltage selectable in B OS setup):
• VT8753 directly supporting pseudo-synchronous SDRAM transfer rate
100/133MHz up to 1.5GB unbuffered DDR SDRAMs or 3GB registered
DDR SDRAMs.
• nstallation of mixed sizes of DDR SDRAM modules supported .
1-1.4 AWARD BIOS V6.0
• Supporting Plug & Play V1.0;
• Flash Memory for easy upgrade;
• Supporting B OS writing protection and Year 2000 compliant;
• B OS Setup supported (Please see Chapter 4 B OS Setup);
1-1 Mainboard Specifications
1-1.5 A elerated Graphi s Port (AGP) Interfa e
AGP Controller is embedded on VT8753, supporting:
• 1.5V/4X, 3.3V/2X power mode , AGP voltage selectable in B OS Setup;
• 2x/ 4x AD and SBA signalling, AGP pipelined split-transection long-
burst transfers up to 1GB/sec.;
• AGP v2.0 compliant;
This manual suits for next models
2
Table of contents
Other SOLTEK Motherboard manuals

SOLTEK
SOLTEK SL-67EB Plus User manual

SOLTEK
SOLTEK SL-52D2 User manual

SOLTEK
SOLTEK 75FRN Series User manual

SOLTEK
SOLTEK B7A-F User manual

SOLTEK
SOLTEK 86SP3 User manual

SOLTEK
SOLTEK SL-75DRV5 User manual

SOLTEK
SOLTEK SL-65F+ User manual

SOLTEK
SOLTEK 85DRV4-C User manual

SOLTEK
SOLTEK 65kv User manual

SOLTEK
SOLTEK 82440FX User manual

SOLTEK
SOLTEK SL-63AV User manual

SOLTEK
SOLTEK SL-K890-754G User manual

SOLTEK
SOLTEK SL-56H5 User manual

SOLTEK
SOLTEK SL-85DR-C User manual

SOLTEK
SOLTEK SL-67B-W User manual

SOLTEK
SOLTEK SL-85DR-C User manual

SOLTEK
SOLTEK 85ERV User manual

SOLTEK
SOLTEK SL-K8T-939FL User manual

SOLTEK
SOLTEK SL-85DIR3 User manual

SOLTEK
SOLTEK SL-65MIE User manual





















