Datalogger Sound Level Meter / EN
09/15/17 Version No. 00 3
3. SPECIFICATIONS
Applicable standards: IEC 61672-1: 2013 Class 2
ANSI S1.4: 1983 Type 2
Measurement functions:
•Main processing functions
Current time-weighted sound pressure level A, C or Z
MaxL: Maximum time-weighted sound pressure level A, C or Z
MinL: Minimum time-weighted sound pressure level A, C or Z
PK: Peak sound pressure level A, C or Z
•Total range: 30 to 130dB
•Max. measurement level: 130dB
•Total linear operating range:In accordance with IEC 61672-1, A-weighted,
1000Hz: 30dB to 130dB
•Level range selection: 3 range in steps 30 to 90dB, 45 to 110dB, 65 to 130dB
Frequency range: Overall characteristics including microphone: 31.5 to
8000Hz
Frequency weighting: A, C and Z filter weightings satisfying IEC 61672-1
Class 2
Time weighting (RMS detection):Fast (F), Slow (S) and Impulse (I)
according to IEC 61672-1 class 2
•Reference conditions:
Type of the acoustic field:Free
Reference sound pressure level: 114.0dB (related to 20µPa)
Reference level range:65 to 130dB
Reference frequency:1000Hz
Reference temperature:+23℃
Reference relative humidity:50%RH
Reference static pressure:101.325 kPa
Reference incidence direction: Perpendicular to the front of the microphone
diaphragm.
•Calibration: Acoustic using sound calibrator.
Calibration check frequency is 1000Hz
Nominal calibration level for the free field: 114.1dB
Nominal calibration level for the diffuse field: 114.0dB
•Frequency for acoustic testing:8000Hz
•Warm-up time:≦2min