HBM T10FH User manual

Mounting Instructions
English
T10FH

Hottinger Baldwin Messtechnik GmbH
Im Tiefen See 45
D-64239 Darmstadt
Tel. +49 6151 803-0
Fax +49 6151 803-9100
www.hbm.com
Mat.: 7-2002.2037
DVS: A2037-5.0 HBM: public
02.2016
EHottinger Baldwin Messtechnik GmbH.
Subject to modifications.
All product descriptions are for general information only.
They are not to be understood as a guarantee of quality or
durability.

T10FH A2037-5.0 HBM: public 3
English
1 Safety instructions 5........................................
2 Scope of supply 9..........................................
3 Application 10...............................................
4 Structure and mode of operation 11...........................
5 Mechanical installation 13....................................
5.1 Conditions on site 14..........................................
5.2 Mounting position 15..........................................
5.3 Mounting sequence 15........................................
5.4 Preparing for the rotor mounting 18.............................
5.5 Mounting the rotor 22..........................................
5.6 Installing the stator 25.........................................
5.7 Installing the clamp fixture 27...................................
5.8 Aligning the stator (speed measuring system) 29..................
6 Electrical connection 32......................................
6.1 General hints 32..............................................
6.2 Shielding design 33...........................................
6.3 Connector pin assignment Option 3, Code SU2 34................
6.4 Connector pin assignment Option 3, Code PNJ 37................
6.5 Supply voltage pin assignment (Option 3, Code SU2) 38...........
6.5.1 Supply voltage for self-contained operation 38....................
6.6 Supply voltage (Option 3, Code PNJ) 39.........................
7 TEDS transducer identification (Option 3, Code PNJ) 40........
7.1 Hierarchy of user rights 40.....................................
7.1.1 Standard rights (USR level) 40.................................
7.1.2 Calibration rights (CAL level) 40................................
7.1.3 Administrator rights (ID level) 41................................
7.2 Content of the TEDS memory as defined in IEEE 1451.4 41........

4A2037-5.0 HBM: public T10FH
8 Shunt signal (Option 3, Code SU2) 46.........................
8.1 Shunt signal 46...............................................
9 Settings (Option 3, Code SU2) 48.............................
9.1 Torque output signal 48........................................
9.2 Setting up the zero point 48....................................
9.3 Function testing 49............................................
9.3.1 Power transmission 49........................................
9.3.2 Checking the speed measuring system 50.......................
9.4 Speed measuring system 51...................................
9.5 Form of speed output signal 51.................................
9.6 Type of speed output signal 52.................................
10 Loading capacity 53.........................................
10.1 Measuring dynamic torque 53..................................
11 Maintenance 55..............................................
12 Specifications 56............................................
13 Dimensions Rotor T10FH rotating; option 2, code L 66.........
14 Dimensions Rotor T10FH non‐rotating; option 2, code N 68....
15 Mounting Dimensions 70.....................................
16 Supplementary technical information; option 2, code L 71......
16.1 Output signals 71.............................................
16.1.1 Output MD for torque (connector 1) 71...........................
16.1.2 Output N for rotation speed (connector 2) 72.....................
16.2 Circular run-out values 73......................................
17 Order number 74............................................
18 Accessories 75..............................................

Safety instructions
T10FH A2037-5.0 HBM: public 5
1 Safety instructions
Appropriate use
The T10FH Torque Flange may be used for
torque‐measurement and directly related control and
regulation tasks only. Any other use is not appropriate.
To ensure safe operation, the transducer may only be
used according to the specifications given in this manual.
When using the transducer, the legal and safety
regulations for the respective application must also be
observed. The same applies if accessories are used.
The transducer is not a safety device in accordance with
the regulations for appropriate use. For correct and safe
operation of these transducers it is essential to ensure
technically correct transportation, storage, installation
and fitting, and to operate all equipment with care.
This is a Class B EMC product. In a domestic
environment this product may cause radio interference in
which case the user may be required to take adequate
measures.
General dangers in the case of non-observance of
the safety instructions
The transducer comply with the state of the art and is
operationally reliable. If the transducer is used and
operated inappropriately by untrained personnel, residual
dangers may arise.
Anyone responsible for installing, operating, maintaining
or repairing these transducers must be sure to have read
and understood the operating manual and in particular
the notes on safety.

Safety instructions
6A2037-5.0 HBM: public T10FH
Residual dangers
The scope of performance and supply of these
transducers covers only part of the torque measurement
technology. In addition, those involved in planning,
constructing and operating the safety engineering
aspects of torque measurement technology must design,
produce and take responsibility for such measures in
order to minimize potential residual dangers. Prevailing
regulations must be complied with at all times. There
must be a clear reference to the residual dangers
connected with measurement technology.
In this manual, the following symbols are used to refer to
residual dangers:
Symbol Significance
WARNING This marking warns of a potentially dangerous
situation in which failure to comply with safety
requirements can result in death or serious physical
injury.
CAUTION This marking warns of a potentially dangerous
situation in which failure to comply with safety
requirements can result in slight or moderate physical
injury.
Notice This marking draws your attention to a situation in
which failure to comply with safety requirements can
lead to damage to property.
Emphasis
See….
Italics are used to emphasize and highlight text and
references to other chapters and external documents.
Symbols pointing out notes on use and waste
disposal as well as useful information:
CE mark
The CE mark enables the manufacturer to guarantee that
the product complies with the requirements of the rele

Safety instructions
T10FH A2037-5.0 HBM: public 7
vant EC directives (the declaration of conformity is avail
able at http://www.hbm.com/HBMdoc).
Statutory marking requirements for waste disposal
National and local regulations regarding the protection of
the environment and recycling of raw materials require
old equipment to be separated from regular domestic
waste for disposal.
For more detailed information on disposal, please contact
the local authorities or the dealer from whom you pur
chased the product.
Reconstruction and modifications
HBM's express consent is required for modifications
affecting the transducers' construction and safety. HBM
does not take responsibility for damage resulting from
unauthorized modifications.
Qualified personnel
The transducers may be used by qualified personnel
only; the technical data and the special safety regulations
must be observed in all cases. When using the transduc
ers, the legal and safety regulations for the respective
application must also be observed. The same applies if
accessories are used.
Qualified personnel means: personnel familiar with the
installation, fitting, start-up and operation of the product,
and trained according to their job.
Prevention of accidents
According to prevailing accident prevention regulations,
after fitting the T10FH torque flange a cover must be
fitted as follows:

Safety instructions
8A2037-5.0 HBM: public T10FH
SThe cover must not be able rotate.
SThe cover shall protect against crushing or cutting and
provide protection against parts that might come
loose.
SThe cover shall be installed at a safe distance from
moving parts or shall prevent anyone putting their
hand inside.
SThe cover shall even be fitted if the moving parts are
installed in areas to which persons do not usually
have access.
The above regulations may only be disregarded if
machine parts are already sufficiently protected owing to
the design of the machine or because other precautions
have been taken.
Guarantee
In the event of a claim, the guarantee can only be
considered if the torque flanges are returned in its
original packing.

Scope of supply
T10FH A2037-5.0 HBM: public 9
2 Scope of supply
STorque flange
SMounting Instructions
STest record
SOptional:
- Magnetic speed measuring system
- PTB calibration certificate in accordance with
DIN 51 309 or EA‐10/14: Class 0.5

Application
10 A2037-5.0 HBM: public T10FH
3 Application
The T10FH torque flange records static and dynamic
torque on fixed or rotating shafts and also return RS422
signals with direction of rotation information to determine
the speed.
The rotating version (frequency and voltage output) is
designed for:
Smarine engine test benches
Stransmissions
Spump test benches
The non-rotating version (mV/V output signal) is
designed for:
Scalibration tasks
Storque reference transducers
Storque transfer transducers
Designed to work without bearings and with contactless
digital signal transmission, the torque measuring system
is maintenance-free.
The torque flange is supplied for nominal (rated) torques
of 100 kN⋅m to 300 kN⋅m. Depending on the nominal
torque, maximum speeds of up to
3 000 min-1 are permissible.
The T10FH torque flange is reliably protected against
electromagnetic interference. It has been tested with
regard to EMC according to the relevant European stan
dards, and carries the CE mark.
Other manuals for T10FH
1
Table of contents
Other HBM Measuring Instrument manuals