HBM T10F User manual

Mounting Instructions
English
T10F

Hottinger Baldwin Messtechnik GmbH
Im Tiefen See 45
D-64239 Darmstadt
Tel. +49 6151 803-0
Fax +49 6151 803-9100
www.hbm.com
Mat.: 7-2001.1510
DVS: A0608-14.0 HBM: public
02.2015
EHottinger Baldwin Messtechnik GmbH.
Subject to modifications.
All product descriptions are for general information only.
They are not to be understood as a guarantee of quality or
durability.

T10F A0608-14.0 HBM: public 3
English
1 Safety instructions 6........................................
2 Markings used 11............................................
2.1 The markings used in this document 11..........................
2.2 Symbols on the product 12.....................................
3 Torque flange versions 13....................................
4 Application 14...............................................
5 Structure and mode of operation 15...........................
6 Mechanical installation 17....................................
6.1 Conditions on site 19..........................................
6.2 Installation orientation 19......................................
6.3 Installation options 20.........................................
6.3.1 Installation without dismantling the antenna ring 21................
6.3.2 Installation with subsequent stator mounting 22...................
6.3.3 Installation example with couplings 23...........................
6.3.4 Installation example with joint shaft 23...........................
6.4 Mounting the rotor 24..........................................
6.5 Mounting the stator 28.........................................
6.6 Installing the clamp fixture 31...................................
6.7 Fitting the slotted disc (speed measuring system) 33..............
6.8 Aligning the stator (speed measuring system) 34..................
7 Electrical connection 37......................................
7.1 General information 37........................................
7.1.1 FCC and IC compliant installation for US and
Canada installation only 38.....................................
7.2 Shielding design 39...........................................
7.3 Option 2, code KF1 41........................................
7.3.1 Adaptation to the cable length 41...............................

4A0608-14.0 HBM: public T10F
7.4 Option 2, code SF1/SU2 43....................................
7.5 Supply voltage 46.............................................
8 Calibration 48...............................................
8.1 Calibration option 2, code KF1 49...............................
8.2 Calibration option 2, code SF1/SU2 49...........................
9 Settings 50..................................................
9.1 Torque output signal, code KF1 51..............................
9.2 Torque output signal, code SF1/SU2 51.........................
9.3 Setting up the zero point 51....................................
9.4 Functional testing 52..........................................
9.4.1 Power transmission 52........................................
9.4.2 Aligning the speed module 53..................................
9.5 Setting the pulse count 55.....................................
9.6 Vibration suppression (hysteresis) 56............................
9.7 Form of speed output signal 56.................................
9.8 Type of speed output signal 58.................................
10 Loading capacity 59.........................................
10.1 Measuring dynamic torque 59..................................
11 Maintenance 61..............................................
11.1 Speed module maintenance 61.................................
12 Dimensions 62..............................................
12.1 Rotor dimensions 62..........................................
12.2 Stator dimensions 64..........................................
12.3 Mounting dimensions 66.......................................

T10F A0608-14.0 HBM: public 5
13 Order numbers, accessories 68...............................
14 Specifications 70............................................
15 Supplementary technical information 78......................
15.1 Output signals 78.............................................
15.1.1 Output MD torque (connector 1) 78..............................
15.1.2 Output N: Speed (connector 2) 79...............................
15.1.3 Connector 2, double frequency, stat. direction of rotation signal 80..
15.2 Axial and radial run‐out tolerances 81............................
15.3 Additional mechanical data 82..................................

Safety instructions
6A0608-14.0 HBM: public T10F
1 Safety instructions
FCC Compliance & Advisory Statement
Important
Any changes or modification not expressly approved by
the party responsible for compliance could void the user's
authority to operate the device. Where specified addi
tional components or accessories elsewhere defined to
be used with the installation of the product, they must be
used in order to ensure compliance with FCC regulations.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2)
this device must accept any interference received, includ
ing interference that may cause undesired operation.
The FCC identifier or the unique identifier, as appropri
ate, must be displayed on the device.
Model Measuring range FCC ID IC
T10S2TO6
50 Nm, 100 Nm, 200 Nm
2ADAT-T10S2TOS6 12438A-T10S2TOS6
500 Nm, 1 kNm
2 kNm, 3 kNm
5 kNm
10 kNm
The FCC ID number in dependence of measuring range.

Safety instructions
T10F A0608-14.0 HBM: public 7
Fig. 1.1 Location of the label on the stator of the device
The preferred position of the FCC label is on the type
plate. If this is not possible for reasons of space, the
label can be found on the rear of the stator housing.
Model: 2ADAT-T10S2TOS6
FCC ID: 2ADAT-T10S2TOS6
IC: 12438AT10S2TOS6
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause unde
sired operation.
Fig. 1.2 Label example with FCC ID and IC number
Industry Canada IC
This device complies with Industry Canada standard
RSS210.
This device complies with Industry Canada license-ex
empt RSS standard(s). Operation is subject to the follow
ing two conditions: (1) this device may not cause interfer
ence, and (2) this device must accept any interference,
including interference that may cause undesired opera
tion of the device.

Safety instructions
8A0608-14.0 HBM: public T10F
Cet appareil est conforme aux normes d'exemption de
licence RSS d'Industry Canada. Son fonctionnement est
soumis aux deux conditions suivantes : (1) cet appareil
ne doit pas causer d'interférence et (2) cet appareil doit
accepter toute interférence, notamment les interférences
qui peuvent affecter son fonctionnement.
Important
Usage/Installation in the USA and Canada requires an
EMI suppressor. Please refer to chapter 7.1.1, page 38.
Designated use
The T10F torque flange is used exclusively for torque
and rotation speed measurement tasks, and directly
associated control and regulatory tasks. Use for any
additional purpose shall be deemed to be not as
intended.
In the interests of safety, the transducer should only be
operated as described in the Operating Manual. It is also
essential to comply with the legal and safety
requirements for the application concerned during use.
The same applies to the use of accessories.
The transducer is not a safety element within the
meaning of its designated use. Proper and safe operation
of this transducer requires proper transportation, correct
storage, assembly and mounting, and careful operation.
General dangers of failing to follow the safety
instructions
The transducer corresponds to the state of the art and is
failsafe. The transducer can give rise to remaining
dangers if it is inappropriately installed and operated by
untrained personnel.

Safety instructions
T10F A0608-14.0 HBM: public 9
Everyone involved with mounting, starting up,
maintaining, or repairing the transducer must have read
and understood the Operating Manual and in particular
the technical safety instructions.
Residual dangers
The scope of supply and performance of the transducer
covers only a small area of torque measurement
technology. In addition, equipment planners, installers
and operators should plan, implement and respond to the
safety engineering considerations of torque
measurement technology in such a way as to minimize
remaining dangers. On‐site regulations must be complied
with at all times. Reference must be made to remaining
dangers connected with torque measurement
technology.
Conversions and modifications
The transducer must not be modified from the design or
safety engineering point of view except with our express
agreement. Any modification shall exclude all liability on
our part for any damage resulting therefrom.
Qualified personnel
The transducer must only be installed and used by
qualified personnel, strictly in accordance with the
specifications and with safety requirements and
regulations. It is also essential to comply with the legal
and safety requirements for the application concerned
during use. The same applies to the use of accessories.
Qualified personnel means persons entrusted with siting,
mounting, starting up and operating the product who
possess the appropriate qualifications for their function.

Safety instructions
10 A0608-14.0 HBM: public T10F
Accident prevention
According to the prevailing accident prevention
regulations, once the torque flange has been mounted, a
covering agent or cladding has to be fitted as follows:
SThe cover or cladding must not be free to rotate.
SThe cover or cladding should avoid squeezing or
shearing and provide protection against parts that
might come loose.
SCovers and cladding must be positioned at a suitable
distance or be arranged so that there is no access to
any moving parts within.
SCovers and cladding must also be attached if the
moving parts of the torque flange are installed outside
peoples' movement and operating range.
The only permitted exceptions to the above requirements
are if the various parts and assemblies of the machine
are already fully protected by the design of the machine
or by existing safety precautions.
Warranty
In the case of complaints, a warranty can only be given if
the torque flange is returned in the original packaging.
Table of contents
Other HBM Measuring Instrument manuals