HBM T40B User manual

Mounting Instructions | Montageanleitung
English Deutsch
T40B

Hottinger Baldwin Messtechnik GmbH
Im Tiefen See 45
D-64239 Darmstadt
Tel. +49 6151 803-0
Fax +49 6151 803-9100
Email: [email protected]
Internet: www.hbm.com
Mat.: 7-2002.3452
DVS: A3452-10.0
11.2014
EHottinger Baldwin Messtechnik GmbH.
Subject to modifications.
All product descriptions are for general information only.
They are not to be understood as a guarantee of quality or
durability.
Änderungen vorbehalten.
Alle Angaben beschreiben unsere Produkte in allgemeiner
Form. Sie stellen keine Beschaffenheits- oder Haltbarkeits
garantie im Sinne des §443 BGB dar.

Mounting Instructions | Montageanleitung
English Deutsch
T40B

2 A3452-10.0 T40B
English
1 Safety instructions 4........................................
2 Markings used 12............................................
2.1 Symbols on the transducer 12..................................
2.2 The markings used in this document 12..........................
3 Application 14...............................................
4 Structure and mode of operation 15...........................
5 Mechanical installation 21....................................
5.1 Important precautions during installation 21......................
5.2 Conditions on site 22..........................................
5.3 Installation orientation 23......................................
5.4 Installation options 23.........................................
5.4.1 Installation without dismantling the antenna ring, Option 7, Code U with
antenna shielding cover 24.....................................
5.4.2 Installation with subsequent stator mounting, Option 7, Code S 25...
5.5 Installing the rotor 26..........................................
5.6 Installing the stator 29.........................................
5.7 Rotational speed measuring system, reference signal (optional) 37..
6 Electrical connection 39......................................
6.1 General information 39........................................
6.2 EMC protection 39............................................
6.3 Connector pin assignment 41...................................
6.4 Supply voltage 47.............................................
7 Shunt signal 49..............................................
8 Functionality testing 50......................................
8.1 Rotor status, LED A (upper LED) 51.............................
8.2 Stator status, LED B (lower LED) 52............................

T40B A3452-10.0 3
9 Load‐carrying capacity 53....................................
10 Maintenance 54..............................................
11 Waste disposal and environmental protection 55..............
12 Ordering numbers, accessories 56............................
13 Specifications 58............................................
13.1 Nominal (rated) torque 50N·m to 500N·m 58....................
13.2 Nominal (rated) torque 1kN·m to 10kN·m 66.....................
14 Supplementary technical information 76......................

Safety instructions
4 A3452-10.0 T40B
1 Safety instructions
FCC Compliance & Advisory Statement for Option 7,
Code U
Important
Any changes or modification not expressly approved in
writing by by the party responsible for compliance could
void the user’s authority to operate the device. Where
specified additional components or accessories else
where defined to be used with the installation of the prod
uct, they must be used in order to ensure compliance
with FCC regulations.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2)
this device must accept any interference received, includ
ing interference that may cause undesired operation.
The FCC identifier or the unique identifier, as appropri
ate, must be displayed on the device.
Model Measuring range FCC ID IC
T40S2TOS6
50 Nm, 100 Nm,
200 Nm
2ADAT−T40S2TOS6 12438A−T40S2TOS6
500 Nm, 1 kNm
2 kNm, 3 kNm
5 kNm
10 kNm

Safety instructions
T40B A3452-10.0 5
Label example with FCC ID and IC number.
Model: T40S2TOS6
FCC ID: 2ADAT-T40S2TOS6
IC: 12438AT40S2TOS6
This device complies with part 15 of the FCC Rules. Opera
tion is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must
accept any interference received, including interference that
may cause undesired operation.
Label
Fig. 1.1 Location of the label on the stator of the device
Model: T40S2TOS6
FCC ID: 2ADAT-T40S2TOS6
IC: 12438AT40S2TOS6
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Fig. 1.2 Example of the label

Safety instructions
6 A3452-10.0 T40B
Industry Canada for Option 7, Code U
Darmstadt, 2014-11-13
This product has not yet received IC (Industry Canada)
approval. The certification process for this product is still
under way. HBM currently expects that IC approval will
be granted by the end of December 2014.
Your local HBM contact looks forward to answer any
questions you may have regarding IC approval.
Darmstadt, le 13 novembre 2014
Ce produit n'a pas encore obtenu l'approbation IC (Indus
trie Canada). Le produit est encore en processus de
certification. Actuellement, HBM suppose que l'appro
bation IC sera accordée jusqu'à fin décembre 2014.
Si vous avez des questions au sujet de l'approbation IC,
veuillez vous adresser à votre représentation HBM sur
place.
This device complies with Industry Canada standard
RSS210.
This device complies with Industry Canada
license−exempt RSS standard(s).Operation is subject to
the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any
interference, including interference that may cause unde
sired operation of the device.
Cet appareil est conforme aux norme RSS210 d’Industrie
Canada.
Cet appareil est conforme aux normes d’exemption de
licence RSS d’Industry Canada. Son fonctionnement est
soumis aux deux conditions suivantes : (1)cet appareil ne
doit pas causer d’interférence et (2) cet appareil doit

Safety instructions
T40B A3452-10.0 7
accepter toute interférence, notamment les interférences
qui peuvent affecter son fonctionnement.
Appropriate use
The T40B torque flange is used exclusively for torque,
angle of rotation and power measurement tasks within
the load limits stipulated in the specifications. Any other
use is not appropriate.
Stator operation is only permitted when the rotor is
installed.
The torque flange may only be installed by qualified per
sonnel in compliance with the specifications and with the
safety requirements and regulations of these mounting
instructions. It is also essential to observe the applicable
legal and safety regulations for the application con
cerned. The same applies to the use of accessories.
The torque flange is not intended for use as a safety
component. Please also refer to the “Additional safety
precautions" section. Proper and safe operation requires
proper transportation, correct storage, siting and mount
ing, and careful operation.
Load carrying capacity limits
The data in the technical data sheets must be complied
with when using the torque flange. In particular, the
respective maximum loads specified must never be
exceeded. For example, the values stated in the specifi
cations must not be exceeded for
Slimit torque,
Slongitudinal limit force, lateral limit force or limit bend
ing moment,
Storque oscillation width,

Safety instructions
8 A3452-10.0 T40B
Sbreaking torque,
Stemperature limits,
Sthe limits of the electrical load‐carrying capacity.
Use as a machine element
The torque flange can be used as a machine element.
When used in this manner, it must be noted that, to favor
greater sensitivity, the transducer is not designed with
the safety factors usual in mechanical engineering.
Please refer here to the section “Load carrying capacity
limits" and to the specifications.
Accident prevention
According to the prevailing accident prevention regula
tions, once the transducers have been mounted, a cover
ing agent or cladding has to be fitted as follows:
SThe covering agent or cladding must not be free to
rotate.
SThe covering agent or cladding should prevent
squeezing or shearing and provide protection against
parts that might come loose.
SCovering agents and cladding must be positioned at a
suitable distance or be so arranged that there is no
access to any moving parts within.
SCovering agents and cladding must still be attached
even if the moving parts of the torque flange are
installed outside people's movement and working
range.
The only permitted exceptions to the above requirements
are if the torque flange is already fully protected by the
design of the machine or by existing safety precautions.
Other manuals for T40B
3
Table of contents
Languages:
Other HBM Measuring Instrument manuals