WIKA 432.55 User manual

E
F
D
GB
Operating instructions
Betriebsanleitung
Mode d'emploi
Manual de instrucciones
Flush diaphragm pressure gauge, model 432.55
Pressure gauge for sanitary applications,
model 432.55
Druckmessgerät für die sterile Verfahrenstechnik,
Typ 432.55
Manomètre pour applications sanitaires,
type 432.55
Manómetro para procesos estériles,
modelo 432.55

E
F
D
GB
2
14055446.01 12/2012 GB/D/F/E
WIKA operating instructions pressure gauge, model 432.55
© 2012 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA®is a registered trademark in various countries.
WIKA®ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Lire le mode d'emploi avant de commencer toute opération !
A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo!
¡Guardar el manual para una eventual consulta!
Operating instructions, model 432.55 Page 3 - 12
Betriebsanleitung, Typ 432.55 Seite 13 - 22
Mode d'emploi, type 432.55 Page 23 - 32
Manual de instrucciones, modelo
432.55 Página 33
-
42

GB
WIKA operating instructions pressure gauge, model 432.55 3
14055446.01 12/2012 GB/D/F/E
1. General information 4
2. Safety 6
3. Specications 7
4. Design and function 8
5. Transport, packaging and storage 9
6. Commissioning, operation 9
7. Maintenance and cleaning 11
8. Faults 11
9. Dismounting and disposal 12
Appendix: Certicate 3-A
Certicate of compliance EHEDG
43
44
Contents
Contents

GB
4 WIKA operating instructions pressure gauge, model 432.55
14055446.01 12/2012 GB/D/F/E
1. General information
The pressure gauge described in the operating instructions has
been designed and manufactured using state-of-the-art technology.
All components are subject to stringent quality and environmental
criteria during production. Our management systems are certied to
ISO 9001 and ISO 14001.
These operating instructions contain important information on
handling the instrument. Working safely requires that all safety
instructions and work instructions are observed.
Observe the relevant local accident prevention regulations and
general safety regulations for the instrument's range of use.
The operating instructions are part of the product and must be kept
in the immediate vicinity of the instrument and readily accessible to
skilled personnel at any time.
Skilled personnel must have carefully read and understood the
operating instructions prior to beginning any work.
The manufacturer's liability is void in the case of any damage
caused by using the product contrary to its intended use,
non-compliance with these operating instructions, assignment
of insuciently qualied skilled personnel or unauthorised
modications to the instrument.
The general terms and conditions contained in the sales
documentation shall apply.
Notes in accordance with pressure equipment directive 97/23/EC
The pressure gauges are pressure accessories in accordance with
article 1, paragraph 2.1.4
1. General information

GB
Applied standards
EN 837-2 Selection and installation recommendations for pressure
gauges
EN 837-3 Diaphragm and capsule pressure gauges, dimensions,
metrology, requirements and testing
Subject to technical modications.
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: PM 04.09
- Application consultant: Tel.: (+49) 9372/132-0
Fax: (+49) 9372/132-406
E-mail: inf[email protected]
Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can
result in serious injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can
result in light injuries or damage to the equipment or the
environment, if not avoided.
Information
... points out useful tips, recommendations and informa-
tion for ecient and trouble-free operation.
WIKA operating instructions pressure gauge, model 432.55 5
14055446.01 12/2012 GB/D/F/E
1. General information

GB
6 WIKA operating instructions pressure gauge, model 432.55
14055446.01 12/2012 GB/D/F/E
2. Safety
WARNING!
Before installation, commissioning and operation, ensure
that the appropriate pressure gauge has been selected
in terms of measuring range, design and suitable wetted
material (corrosion) for the specic measuring conditions.
In order to guarantee the measuring accuracy and
long-term stability specied, the corresponding load
limits must be observed.
Non-observance can result in serious injury and/or
damage to the equipment.
Further important safety instructions can be found in the
individual chapters of these operating instructions.
2.1 Intended use
The model 432.55 pressure gauge is used for measuring pressure
particularly in sanitary applications.
The instrument has been designed and built solely for the intended
use described here, and may only be used accordingly.
The manufacturer shall not be liable for claims of any type based on
operation contrary to the intended use.
2.2 Personnel qualication
WARNING!
Risk of injury should qualication be insucient!
Improper handling can result in considerable injury and
damage to equipment.
2. Safety

GB
WIKA operating instructions pressure gauge, model 432.55 7
14055446.01 12/2012 GB/D/F/E
The activities described in these operating
instructions may only be carried out by skilled
personnel who have the qualications described
below.
Skilled personnel
Skilled personnel are understood to be personnel who, based on their
technical training, knowledge of measurement and control technology
and on their experience and knowledge of country-specic regula-
tions, current standards and directives, are capable of carrying out the
work described and independently recognising potential hazards.
2.3 Special hazards
WARNING!
For hazardous media such as acids, bases, amma-
ble or toxic gases or liquids, in addition to all standard
regulations, the appropriate existing codes or regulations
must also be followed.
WARNING!
Residual media in dismounted instruments can result in
a risk to persons, the environment and equipment.Take
sucient precautionary measures.
3. Specications
Pressure limitation
Steady: Full scale value
Fluctuating: 0.9 x full scale value
Short time: 1.5 x full scale value
Permissible temperature
Ambient: -20 ... +60 °C
Medium: +150 °C maximum
2. Safety / 3. Specications

GB
8 WIKA operating instructions pressure gauge, model 432.55
14055446.01 12/2012 GB/D/F/E
Temperature eect
When the temperature of the measuring system deviates from the
reference temperature (+20 °C): max. ±0.8 %/10 K of full scale value
Ingress protection
IP 54 per EN 60529 / IEC 529
For further specications see WIKA data sheet PM 04.09 and the
order documentation.
4. Design and function
4.1 Description
The model 432.55 pressure gauge is designed especially for the
requirements of the food and beverage, pharmaceutical and biotech-
nology industries.
The pressure gauge is particularly suitable for the special conditions of
CIP/SIP cleaning processes, e.g. thanks to chemical stability towards
cleaning liquids and high temperatures. The ush metal diaphragm
element is directly welded to the process connection.This guarantees
a crevice-free connection of process connection and diaphragm
element; additional internal sealings are not required.
4.2 Scope of delivery
Cross-check scope of delivery with delivery note.
3. Specications / 4. Design and function

GB
WIKA operating instructions pressure gauge, model 432.55 9
14055446.01 12/2012 GB/D/F/E
5. Transport, packaging ... / 6. Commissioning ...
5. Transport, packaging and storage
5.1 Transport
Check the pressure gauge for any damage that may have been
caused by transport. Obvious damage must be reported immediately.
5.2 Packaging
Do not remove packaging until just before mounting.
Keep the packaging as it will provide optimum protection during
transport (e.g. change in installation site).
5.3 Storage
Permissible conditions at the place of storage:
Storage temperature: -20 ... +70 °C
Protect the pressure gauge from dust.
6. Commissioning, operation
The pressure gauge should be kept in its packing until installation.
The gauge should be protected from external damage during
storage.
On removal from the packaging, and during mounting, particular
care must be taken to avoid damage and any mechanical
deformation to the diaphragm.

GB
10 WIKA operating instructions pressure gauge, model 432.55
14055446.01 12/2012 GB/D/F/E
Installation
Do not damage the diaphragm; scratches on the diaphragm (e.g.
from sharp-edged objects) are the main causes of corrosion.
For sealing, choose appropriate seals.
For ange mounting, only use sealings with a suciently large inner
diameter and centre them; contact with the diaphragm leads to
measuring errors.
When using soft or PTFE sealings, observe the instructions of the
sealing manufacturer, particularly with regard to tightening torque
and load cycles.
For installation, in accordance with the tting and ange standards
the appropriate fastenings, such as screws and nuts, must be used.
Permissible ambient and operating temperatures
When mounting the pressure gauge it must be ensured that, taking
into consideration the inuence of convection and heat radiation,
no deviation above or below the permissible ambient and medium
temperatures can occur. The inuence of temperature on the indication
accuracy must be observed.
In order to avoid any additional heating, the instruments must not be
exposed to direct solar irradiation while in operation!
Permissible vibration load at the installation site
The instruments should always be installed in locations free from
vibration.
Commissioning
During the commissioning process pressure surges must be avoided
at all costs.
6. Commissioning, operation
Table of contents
Languages:
Other WIKA Measuring Instrument manuals

WIKA
WIKA DPT-10 User manual

WIKA
WIKA mensor 9476 User manual

WIKA
WIKA CTD9100-1100 User manual

WIKA
WIKA PG23CP User manual

WIKA
WIKA 700.01.080 User manual

WIKA
WIKA 55 Series Operating instructions

WIKA
WIKA FLC-UFL Series User manual

WIKA
WIKA 4x2.30.1x0 Series User manual

WIKA
WIKA IBF1 User manual

WIKA
WIKA CPH62I0-S1 User manual