TX6386 • TX6387 User Manual
TX6386/7-UM-EN-04 9
Cable entries 3 x M20
Electrical connections 4 mm (0.15 inch) barrier/clamp terminals
Conductors A maximum of two per terminal
Conductor size A maximum of 2 x 2.5 mm² (0.003875 inch²)
Terminal torque 2.4 Nm maximum
Display TX6386: 7 segment, high brightness LED,
20 mm (0.8 inch) characters
TX6387: 7 segment, high brightness LED,
100 mm (4 inch) characters
Vibration limits
(BS 2011)
10 to 100 Hz: 0.25 mm (0.009842 inch) peak
100 to 600 Hz: 2 g peak
Impact limits 20 joules (housing)
Ambient pressure limits 1013 mbar ± 100 mbar absolute
Sensing principle Catalytic combustion
Linearity Linear: 0 to 3% v/v
± 0.2% v/v: 3 to 4% v/v
Drift ± 0.25% v/v per month (at 25°C (77°F))
Response time (T90) < 20 seconds
Warm up time < 5 minutes in air or 1% v/v CH4
(to 95% stated accuracy)
Calibration Front mounted potentiometers
Over range If the measured gas concentration exceeds the
calibration range of the sensor, the display will
indicate FAULT
Pellistor protection The supply to the gas sensing element will be
switched off to prevent oxidisation damage
occurring if the gas concentration exceeds safe
limits. The sensor will remain switched off until
reset.
www.trolex.com