Sonel MIC-10k1 User manual





USER MANUAL
INSULATION RESISTANCE METERS
MIC-10k1 and MIC-5050
SONEL S.A.
Wokulskiego 11
58-100 Świdnica, Poland
Version 1.12 07.06.2018

MIC-10k1, MIC-5050 –USER MANUAL
2
MIC-10k1 and MIC-5050 meters are modern, high-quality meters, easy and safe in operation. Please
acquaint yourself with this manual in order to avoid measuring errors and prevent possible problems
in operation of the meter.

MIC-10k1, MIC-5050 –USER MANUAL
3
CONTENTS
1Safety ................................................................................................................5
2Menu..................................................................................................................6
2.1 Wireless transmission ...............................................................................................6
2.2 Measurement Settings ..............................................................................................7
2.2.1 Mains frequency................................................................................................................7
2.2.2 Times t1, t2, t3 for calculating absorption coefficients........................................................8
2.2.3 Type of absorption coefficients..........................................................................................8
2.2.4 IISO test current..................................................................................................................8
2.2.5 Setting limit values............................................................................................................9
2.2.6 Temperature unit...............................................................................................................9
2.2.7 Auto-incrementing of the memory cell number ................................................................10
2.2.8 Filter................................................................................................................................10
2.2.9 Chart type selection ........................................................................................................10
2.3 Meter Settings.........................................................................................................11
2.3.1 LCD contrast...................................................................................................................12
2.3.2 Automatic shut-off (Auto-OFF) ........................................................................................12
2.3.3 Date and time..................................................................................................................12
2.3.4 Factory (default) settings.................................................................................................13
2.3.5 Software update..............................................................................................................13
2.3.6 Key sounds.....................................................................................................................14
2.3.7 Wireless communication .................................................................................................14
2.4 Language choice.....................................................................................................15
2.5 Information about manufacturer..............................................................................15
3Measurements................................................................................................15
3.1 Diagnostics performed by the meter - limits............................................................16
3.2 Measurement of insulation resistance.....................................................................16
3.2.1 Double-lead measurement..............................................................................................17
3.2.2 Three-lead measurement................................................................................................22
3.2.3 Measurements with AutoISO-5000..................................................................................24
3.2.4 Measurements with increasing voltage - SV....................................................................27
3.2.5 Dielectric Discharge Indicator - DD..................................................................................29
3.2.6 Damage location (after-burning)......................................................................................31
3.3 Low-voltage measurement of resistance.................................................................33
3.3.1 Measurement of resistance of protective conductors and equipotential bonding with ±200
mA current......................................................................................................................33
3.3.2 Calibration of test leads...................................................................................................35
3.4 Temperature Measurement.....................................................................................36
4Memory of measurement results .................................................................37
4.1 Structure of the Memory..........................................................................................37
4.1.1 The appearance of main windows in the measurement recording mode..........................37
4.2 Storing the measurement results in the memory.....................................................39
4.2.1 Entering the results without extending the memory structure...........................................39
4.2.2 Extending the memory structure......................................................................................40
4.3 Viewing memory data..............................................................................................45
4.4 Deleting memory data.............................................................................................47

MIC-10k1, MIC-5050 –USER MANUAL
4
5Data transmission..........................................................................................48
5.1 Set of accessories to connect the meter to a PC ....................................................48
5.2 Data transmission through USB port.......................................................................48
5.3 Connecting to Bluetooth mini-keyboard...................................................................49
5.3.1 Manual connection..........................................................................................................49
5.3.2 Automatic connection......................................................................................................51
5.4 Data transmission using Bluetooth module.............................................................51
5.5 Read-out and change of PIN code for Bluetooth connections.................................52
6Power supply of the meter............................................................................53
6.1 Monitoring the power supply voltage.......................................................................53
6.2 Battery power..........................................................................................................53
6.3 Charging rechargeable battery................................................................................53
6.4 Power supply from mains........................................................................................54
6.5 General principles for using Li-Ion rechargeable batteries......................................54
6.6 General principles for using gel (lead) rechargeable batteries ................................55
7Cleaning and maintenance ...........................................................................55
8Storage............................................................................................................56
9Dismantling and utilisation...........................................................................56
10 Technical specifications ...............................................................................56
10.1 Basic data ...............................................................................................................56
10.2 Additional data ........................................................................................................59
10.2.1 Additional uncertainties according to EN 61557-2 (RISO)..................................................59
10.2.2 Additional uncertainties according to EN 61557-4 (RCONT)...............................................60
11 Equipment ......................................................................................................60
11.1 Standard equipment................................................................................................60
11.2 Optional accessories...............................................................................................60
12 Manufacturer ..................................................................................................62

MIC-10k1, MIC-5050 –USER MANUAL
5
1 Safety
MIC-10k1 and MIC-5050 meters are designed for performing check tests of protection against
electric shock in mains systems. The meters are used for making measurements and providing results
to determine safety of electrical installations. Therefore, in order to provide conditions for correct oper-
ation and accuracy of obtained results, the following recommendations must be observed:
Before you proceed to operate the meter, acquaint yourself thoroughly with the present manual
and observe the safety regulations and specifications provided by the producer.
Any application that differs from those specified in the present manual may result in a damage to
the device and constitute a source of danger for the user.
MIC-10k1 and MIC-5050 meters must be operated only by appropriately qualified personnel with
relevant certificates authorising the personnel to perform works on electric systems. Operating the
meter by unauthorised personnel may result in damage to the device and constitute a source of
danger for the user.
During measurements of insulation resistance, dangerous voltage up to 10 kV (MIC-10k1) or 5 kV
(MIC-5050) occurs at the ends of test leads of the meter.
Before the measurement of insulation resistance you must be sure that tested object is discon-
nected from the power supply.
During the measurement of insulation resistance do not disconnect test leads from the tested ob-
ject before the measurement is completed (see par. 0); otherwise the capacitance of the object will
not be discharged, creating the risk of electric shock.
Using this manual does not exclude the need to comply with occupational health and safety regu-
lations and with other relevant fire regulations required during the performance of a particular type
of work. Before starting the work with the device in special environments, e.g. potentially fire-
risk/explosive environment, it is necessary to consult it with the person responsible for health and
safety.
It is unacceptable to operate:
a damaged meter which is completely or partially out of order,
a meter with damaged insulation,
a meter stored for an excessive period of time in disadvantageous conditions (e.g. excessive
humidity). If the meter has been transferred from a cool to a warm environment with a high
level of relative humidity, do not start measurements until the meter is warmed up to the ambi-
ent temperature (approximately 30 minutes).
Remember that BAT! message appearing on the display indicates insufficient voltage of power
supply and the need to recharge the batteries.
Before measurement, choose a correct measurement function and make sure that test leads are
connected to respective measuring terminals.
Do not power the meter from sources other than those listed in this manual.
RISO meter inputs are electronically protected against overloads (caused by e.g. connecting the
meter to a live circuit) up to 825 V for 60 seconds.
Repairs may be performed only by an authorised service point.
ATTENTION!
11 kV DC crocodile clips and probes are designed to work only on objects without voltage.
Note:
Due to continuous development of the meter’s software, the actual appearance of the dis-
play, in case of some of the functions, may slightly differ from the display presented in this
operating manual.

MIC-10k1, MIC-5050 –USER MANUAL
6
ATTENTION!
To display the correct battery discharge status, it is necessary to completely discharge
and then fully charge the battery, before starting the regular use of the meter.
Note:
An attempt to install drivers in 64-bit Windows 8 may result in displaying "Installation
failed" message.
Cause: Windows 8 by default blocks drivers without a digital signature.
Solution: Disable the driver signature enforcement in Windows.
2 Menu
Press MENU button.
The main menu contains the following items:
Wireless transmission
Measurement Settings
Meter Settings
Language selection
Information about manufacturer
Use , and , buttons to select desired posi-
tion. Enter a selected option by pressing ENTER.
2.1 Wireless transmission
See sections 5.3 to 5.5.
Other manuals for MIC-10k1
3
This manual suits for next models
1
Table of contents
Other Sonel Measuring Instrument manuals