R&S FSV-K8 User manual

R&S® FSV-K8
Firmware Option Bluetooth
Measurements
Operating Manual
Operating Manual
(;ÚÚ:2)
1176.7610.02 ─ 02
Test & Measurement

This manual describes the following R&S®FSV options:
●R&S FSV-K8 (1310.8155.02)
This manual describes the following R&S®FSV models with firmware version 2.20 and higher:
●R&S®FSV 4 (1321.3008K04)
●R&S®FSV 7 (1321.3008K07)
●R&S®FSV 13 (1321.3008K13)
●R&S®FSV 30 (1321.3008K30)
●R&S®FSV 40 (1321.3008K39)
●R&S®FSV 40 (1321.3008K40)
It also applies to the following R&S®FSV models. However, note the differences described in chapter 1.4,
"Notes for Users of R&S FSV 1307.9002Kxx Models", on page 9.
●R&S®FSV 3 (1307.9002K03)
●R&S®FSV 7 (1307.9002K07)
●R&S®FSV 13 (1307.9002K13)
●R&S®FSV 30 (1307.9002K30)
●R&S®FSV 40 (1307.9002K39)
●R&S®FSV 40 (1307.9002K40)
The firmware of the instrument makes use of several valuable open source software packages. For information, see the "Open
Source Acknowledgement" on the user documentation CD-ROM (included in delivery).
Rohde & Schwarz would like to thank the open source community for their valuable contribution to embedded computing.
© 2014 Rohde & Schwarz GmbH & Co. KG
Mühldorfstr. 15, 81671 München, Germany
Phone: +49 89 41 29 - 0
Fax: +49 89 41 29 12 164
E-mail: [email protected]
Internet: www.rohde-schwarz.com
Subject to change – Data without tolerance limits is not binding.
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG.
The Bluetooth® word mark and logos are owned by Bluetooth SIG, Inc. and any use of such marks by Rohde & Schwarz is under
license.
Trade names are trademarks of the owners.
The following abbreviations are used throughout this manual: R&S®FSV is abbreviated as R&S FSV.

Contents
R&S® FSV-K8
3Operating Manual 1176.7610.02 ─ 02
Contents
1Preface.................................................................................................... 5
1.1 Documentation Overview............................................................................................. 5
1.2 Conventions Used in the Documentation...................................................................7
1.3 How to Use the Help System........................................................................................8
1.4 Notes for Users of R&S FSV 1307.9002Kxx Models.................................................. 9
2Introduction to Bluetooth Measurements (K8)..................................10
2.1 Bluetooth Overview.................................................................................................... 10
2.2 Supported Tests..........................................................................................................12
2.3 Overview of Transmitter Tests...................................................................................13
2.4 Functional Description – Block Diagram.................................................................. 14
2.5 Bandwidths..................................................................................................................15
2.6 Measurement Filter (Meas Filter On)......................................................................... 16
2.7 Oversampling ............................................................................................................. 16
2.8 Determining Average or Max/Min Values..................................................................18
2.9 Trigger Concepts ....................................................................................................... 19
3Instrument Functions for Bluetooth Measurements (K8).................20
3.1 Measurement Types and Result Display.................................................................. 22
3.2 Adapting the settings to the characteristics of the DUT......................................... 33
3.3 Softkeys of the Bluetooth Menu................................................................................ 34
3.4 Softkeys of the MEAS CONFIG menu....................................................................... 49
3.5 Softkeys of the Amplitude Menu (Bluetooth Mode).................................................49
3.6 Softkeys of the Bandwidth Menu (option R&S FSV-K8)..........................................53
3.7 Softkeys of the Frequency Menu (option R&S FSV-K8).......................................... 55
3.8 Softkeys of the Sweep Menu (Bluetooth mode).......................................................56
3.9 Softkeys of the Trigger Menu (Option R&S FSV-K8)............................................... 60
3.10 Further Information.....................................................................................................64
4Remote Commands for Bluetooth Measurements (K8)....................67
4.1 CALCulate subsystem................................................................................................ 67
4.2 CONFigure:BTOoth Subsystem (BLUETOOTH, K8)................................................ 91
4.3 DISPlay Subsystem (BLUETOOTH, K8).................................................................. 105

Contents
R&S® FSV-K8
4Operating Manual 1176.7610.02 ─ 02
4.4 FORMat subsystem...................................................................................................109
4.5 INITiate subsystem................................................................................................... 109
4.6 INPut subsystem....................................................................................................... 110
4.7 INSTrument Subsystem (BLUETOOTH, K8)........................................................... 112
4.8 SENSe Subsystem (BLUETOOTH, K8)....................................................................112
4.9 SENSe:ADEMod Subsystem (BLUETOOTH, K8)....................................................119
4.10 SENSe:DDEMod Subsystem (BLUETOOTH, K8)....................................................120
4.11 SYSTem subsystem..................................................................................................123
4.12 TRACe subsystem.................................................................................................... 124
4.13 TRIGger subsystem.................................................................................................. 125
4.14 Programming Example............................................................................................. 127
List of Commands..............................................................................129
Index....................................................................................................132

Preface
R&S® FSV-K8
5Operating Manual 1176.7610.02 ─ 02
1 Preface
1.1 Documentation Overview
The user documentation for the R&S FSV is divided as follows:
●Quick Start Guide
●Operating Manuals for base unit and options
●Service Manual
●Online Help
●Release Notes
Quick Start Guide
This manual is delivered with the instrument in printed form and in PDF format on the
CD. It provides the information needed to set up and start working with the instrument.
Basic operations and basic measurements are described. Also a brief introduction to
remote control is given. The manual includes general information (e.g. Safety Instruc-
tions) and the following chapters:
Chapter 1 Introduction, General information
Chapter 2 Front and Rear Panel
Chapter 3 Preparing for Use
Chapter 4 Firmware Update and Installation of Firmware Options
Chapter 5 Basic Operations
Chapter 6 Basic Measurement Examples
Chapter 7 Brief Introduction to Remote Control
Appendix Printer Interface
Appendix LAN Interface
Operating Manuals
The Operating Manuals are a supplement to the Quick Start Guide. Operating Manuals
are provided for the base unit and each additional (software) option.
The Operating Manual for the base unit provides basic information on operating the
R&S FSV in general, and the "Spectrum" mode in particular. Furthermore, the software
options that enhance the basic functionality for various measurement modes are
described here. The set of measurement examples in the Quick Start Guide is expan-
ded by more advanced measurement examples. In addition to the brief introduction to
remote control in the Quick Start Guide, a description of the basic analyzer commands
and programming examples is given. Information on maintenance, instrument interfa-
ces and error messages is also provided.
Documentation Overview

Preface
R&S® FSV-K8
6Operating Manual 1176.7610.02 ─ 02
In the individual option manuals, the specific instrument functions of the option are
described in detail. For additional information on default settings and parameters, refer
to the data sheets. Basic information on operating the R&S FSV is not included in the
option manuals.
The following Operating Manuals are available for the R&S FSV:
●R&S FSV base unit; in addition:
–R&S FSV-K9 Power Sensor Support
–R&S FSV-K14 Spectrogram Measurement
●R&S FSV-K7 Analog Demodulation and R&S FSV-K7S FM Stereo Measurements
●R&S FSV-K10 GSM/EDGE Measurement
●R&S FSV-K30 Noise Figure Measurement
●R&S FSV-K40 Phase Noise Measurement
●R&S FSV-K70 Vector Signal Analysis Operating Manual
R&S FSV-K70 Vector Signal Analysis Getting Started (First measurements)
●R&S FSV-K72 3GPP FDD BTS Analysis
●R&S FSV-K73 3GPP FDD UE Analysis
●R&S FSV-K76/77 3GPP TD-SCDMA BTS/UE Measurement
●R&S FSV-K82/83 CDMA2000 BTS/MS Analysis
●R&S FSV-K84/85 1xEV-DO BTS/MS Analysis
●R&S FSV-K91 WLAN IEEE 802.11
●R&S FSV-K93 WiMAX IEEE 802.16 OFDM/OFDMA Analysis
●R&S FSV-K100/K104 EUTRA / LTE Downlink Measurement Application
●R&S FSV-K101/K105 EUTRA / LTE Uplink Measurement Application
These manuals are available in PDF format on the CD delivered with the instrument.
Service Manual
This manual is available in PDF format on the CD delivered with the instrument. It
describes how to check compliance with rated specifications, instrument function,
repair, troubleshooting and fault elimination. It contains all information required for
repairing the R&S FSV by replacing modules. The manual includes the following chap-
ters:
Chapter 1 Performance Test
Chapter 2 Adjustment
Chapter 3 Repair
Chapter 4 Software Update / Installing Options
Chapter 5 Documents
Online Help
The online help contains context-specific help on operating the R&S FSV and all avail-
able options. It describes both manual and remote operation. The online help is instal-
Documentation Overview

Preface
R&S® FSV-K8
7Operating Manual 1176.7610.02 ─ 02
led on the R&S FSV by default, and is also available as an executable .chm file on the
CD delivered with the instrument.
Release Notes
The release notes describe the installation of the firmware, new and modified func-
tions, eliminated problems, and last minute changes to the documentation. The corre-
sponding firmware version is indicated on the title page of the release notes. The cur-
rent release notes are provided in the Internet.
1.2 Conventions Used in the Documentation
1.2.1 Typographical Conventions
The following text markers are used throughout this documentation:
Convention Description
"Graphical user interface ele-
ments"
All names of graphical user interface elements on the screen, such as
dialog boxes, menus, options, buttons, and softkeys are enclosed by
quotation marks.
KEYS Key names are written in capital letters.
File names, commands,
program code
File names, commands, coding samples and screen output are distin-
guished by their font.
Input Input to be entered by the user is displayed in italics.
Links Links that you can click are displayed in blue font.
"References" References to other parts of the documentation are enclosed by quota-
tion marks.
1.2.2 Conventions for Procedure Descriptions
When describing how to operate the instrument, several alternative methods may be
available to perform the same task. In this case, the procedure using the touchscreen
is described. Any elements that can be activated by touching can also be clicked using
an additionally connected mouse. The alternative procedure using the keys on the
instrument or the on-screen keyboard is only described if it deviates from the standard
operating procedures.
The term "select" may refer to any of the described methods, i.e. using a finger on the
touchscreen, a mouse pointer in the display, or a key on the instrument or on a key-
board.
Conventions Used in the Documentation

Preface
R&S® FSV-K8
8Operating Manual 1176.7610.02 ─ 02
1.3 How to Use the Help System
Calling context-sensitive and general help
► To display the general help dialog box, press the HELP key on the front panel.
The help dialog box "View" tab is displayed. A topic containing information about
the current menu or the currently opened dialog box and its function is displayed.
For standard Windows dialog boxes (e.g. File Properties, Print dialog etc.), no context-
sensitive help is available.
► If the help is already displayed, press the softkey for which you want to display
help.
A topic containing information about the softkey and its function is displayed.
If a softkey opens a submenu and you press the softkey a second time, the submenu
of the softkey is displayed.
Contents of the help dialog box
The help dialog box contains four tabs:
●"Contents" - contains a table of help contents
●"View" - contains a specific help topic
●"Index" - contains index entries to search for help topics
●"Zoom" - contains zoom functions for the help display
To change between these tabs, press the tab on the touchscreen.
Navigating in the table of contents
●To move through the displayed contents entries, use the UP ARROW and DOWN
ARROW keys. Entries that contain further entries are marked with a plus sign.
●To display a help topic, press the ENTER key. The "View" tab with the correspond-
ing help topic is displayed.
●To change to the next tab, press the tab on the touchscreen.
Navigating in the help topics
●To scroll through a page, use the rotary knob or the UP ARROW and DOWN
ARROW keys.
●To jump to the linked topic, press the link text on the touchscreen.
Searching for a topic
1. Change to the "Index" tab.
How to Use the Help System

Preface
R&S® FSV-K8
9Operating Manual 1176.7610.02 ─ 02
2. Enter the first characters of the topic you are interested in. The entries starting with
these characters are displayed.
3. Change the focus by pressing the ENTER key.
4. Select the suitable keyword by using the UP ARROW or DOWN ARROW keys or
the rotary knob.
5. Press the ENTER key to display the help topic.
The "View" tab with the corresponding help topic is displayed.
Changing the zoom
1. Change to the "Zoom" tab.
2. Set the zoom using the rotary knob. Four settings are available: 1-4. The smallest
size is selected by number 1, the largest size is selected by number 4.
Closing the help window
► Press the ESC key or a function key on the front panel.
1.4 Notes for Users of R&S FSV 1307.9002Kxx Models
Users of R&S FSV 1307.9002Kxx models should consider the following differences to
the description of the newer R&S FSV 1321.3008Kxx models:
●Functions that are based on the Windows7 operating system (e.g. printing or set-
ting up networks) may have a slightly different appearance or require different set-
tings on the Windows XP based models. For such functions, refer to the Windows
documentation or the documentation originally provided with the R&S FSV instru-
ment.
●The R&S FSV 1307.9002K03 model is restricted to a maximum frequency of
3 GHz, whereas the 1321.3008K04 model has a maximum frequency of 4 GHz.
●The bandwidth extension option R&S FSV-B160 (1311.2015.xx) is not available for
the R&S FSV 1307.9002Kxx models. The maximum usable I/Q analysis bandwidth
for these models is 28 MHz, or with option R&S FSV-B70, 40 MHz.
Notes for Users of R&S FSV 1307.9002Kxx Models

Introduction to Bluetooth Measurements (K8)
R&S® FSV-K8
10Operating Manual 1176.7610.02 ─ 02
2 Introduction to Bluetooth Measurements
(K8)
Overview of Firmware Option R&S FSV-K8
This section contains all information required for operation of an R&S FSV equipped
with Application Firmware R&S FSV–K8. It covers operation via menus and the remote
control commands for bluetooth measurements.
This part of the documentation consists of the following chapters:
●chapter 2, "Introduction to Bluetooth Measurements (K8)", on page 10
Introduces the Bluetooth option and provides further information.
●chapter 3, "Instrument Functions for Bluetooth Measurements (K8)", on page 20
Shows all softkeys available in the "Bluetooth" menu. This chapter also presents
the remote control commands associated with each softkey function.
●chapter 4, "Remote Commands for Bluetooth Measurements (K8)", on page 67
Describes all remote control commands defined for bluetooth measurements.
This part of the documentation includes only functions of the Application Firmware
R&S FSV–K8. For all other descriptions, refer to the description of the base unit.
2.1 Bluetooth Overview.................................................................................................... 10
2.2 Supported Tests..........................................................................................................12
2.3 Overview of Transmitter Tests...................................................................................13
2.4 Functional Description – Block Diagram.................................................................. 14
2.5 Bandwidths..................................................................................................................15
2.6 Measurement Filter (Meas Filter On)......................................................................... 16
2.7 Oversampling ............................................................................................................. 16
2.8 Determining Average or Max/Min Values..................................................................18
2.9 Trigger Concepts ....................................................................................................... 19
2.1 Bluetooth Overview
This section provides the following general information on Bluetooth measurements:
●Bluetooth technical parameters
●Power classes
●Structure of a Bluetooth data packet
Bluetooth Overview
Table of contents
Other R&S Measuring Instrument manuals