MRC PS-9302 User manual

PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION
MRC.VER.02-11.10
INSTRUCTION MANUAL FOR
PS-9302
PRESSURE METER

TABLE OF CONTENTS
1. FEATURES................................................................... 1
2.
T
YPICAL APPLICATION................................................
.
2
3. SPECIFICATIONS.........................................................2
3-1 General Specifications............................................
.
2
3-2 Electrical Specifications..........................................
.
3
4. FRONT PANEL DESCRIPTION.......................................
.
5
4-1 Display................................................................5
4-2 Power Button......................................................
.
5
4-3 Data Hold Button................................................. 5
4-4 " Max./Min. " Button............................................
.
5
4-5 Unit Button..........................................................5
4-6 Zero Button......................................................... 5
4-7 Sensor Type Button.............................................
.
5
4-8 Battery Compartment/Cover................................. 5
4-9 Sensor Input Socket.............................................5
4-10 RS-232 Output Terminal....................................... 5
4-11 Port Connector of Pressure Sensor........................
.
5
4-12 Pressure Sensor Main body................................... 5
4-13 Plug of Pressure Sensor........................................5
5. SENSOR TYPE SELECTION...........................................
.
6
6. MEASURING PROCEDURE............................................
.
8
7.
A
UTO POWER DISABLE................................................10
8. CALIBRATION..............................................................11
9. RS232 PC SERIAL INTERFACE......................................
.
14
10. BATTERY REPLACEMENT............................................16
11. OPTIONAL PRESSURE SENSOR...................................16
12. OTHER OPTIONAL ACCESSORIES............................... 17

1. FEATURES
* Meter can cooperate with 2, 5, 10, 20, 50, 100, 200, 400 Bar
sensor, new calibration procedures are not necessary when
change the new sensor .
* When change the new pressure sensor, just select
pressure type ( 2, 5, 10, 20, 50, 100, 200, 400 bar ) on the
front panel button. The sensor type will memorize into
the circuit permanently.
* 8 kind pressure units ( Bar, Psi, Kg/cm 2 mm/Hg, inch/Hg,
meter/HF2 , inch/HF2 , Atmosphere ), unit select by push
button on the front panel.
* Full line optional pressure sensors are available.
* Auto power off function, saves battery life.
* Cooperate the external pressure sensor that its output
signal is 100 mV for full scale.
* Zero button on the front panel, easy adjust the zero value
of pressure sensor.
* Available push button gain adjustment, usage for
calibration precisely if necessary.
* Separate pressure sensor, easy for remote measurement.
* Microprocessor circuit assures maximum possible accuracy,
provides special functions and features,
* Super large LCD display, easy readout.
* Records maximum & minimum readings with recall.
* Data Hold function, store the desired value on display.
* Built-in low battery indicator.
* RS 232 PC serial interface, can cooperate the personal
computer used as the Data Logger, Pressure Recorder....
& other modern pressure measuring system.
1

2. TYPICAL APPLICATION
* Measure pneumatic pressures.
* Measure automobile engine pressures.
* Pressure for super heat measurements.
* Hydraulic servo controls.
* Refrigeration.
* Air conditioning.
* Food processing.
3
.
SPECIFICATIONS
3-1 General Specifications
Circuit Microprocessor LSI circuit.
Display 61 mm x 34 mm supper lar
g
e LCD display.
15 mm ( 0.6" ) di
g
it size.
Sensor type Can cooperate with optional 2, 5, 10, 20, 50,
100, 200, 400 bar sensor, new calibration are
not necessary when chan
g
e the new sensor .
Display units Bar, Psi, Kg/cm 2 mm/Hg, inch/Hg,
meter/HF2 , inch/HF2 , Atmosphere.
Accuracy ( 0.5% + 1 d )
*
Under the si
g
nal from the sensor is at full
scale ( 100 mV ).
* Meter only.
* Within 23
蚓
5
蚓
Pressure Cooperate the external pressure sensor that
sensor its output si
g
nal is 100 mV for full scale.
ref. pa
g
e 1
6
Zero ad
j
ust Push button on the front panel.
Span ad
j
ust Push button
g
ain ad
j
ustment, usa
g
e for
calibration precisely if necessary.
Input si
g
nal DC 100 mV for full Scale.
from sensor
2

Data hold By push button.
Data record Record maximum & minimum readin
g
s.
Data output RS 232 PC serial interface.
Power of
f
Auto shut off, saves battery life.
Manual off by push button.
Samplin
g
time Approx. 0.8 second.
Operatin
g
0 to 50
蚓
( 32 to 122
蚌
)
temperature
Operatin
g
Less than 80% R.H.
humidity
Power supply Alkaline or heavy duty type DC 9V battery,
006P, MN1604 (PP3) or equivalent.
Power current Approx. DC 7.0 mA.
Wei
g
ht 345
g
/0.76 LB
Dimension 180 x 72 x 32 mm ( 7.1 x 2.8 x 1.3 inch ).
Accessories * Instruction manual...........................1 PC
included
Optional * Pressure sensor, PS100-xxBAR,
accessories * Hard carryin
g
case ( CA-06 )
* Data acquisition software ( Windows
ref. page 16, 17
version ), SW-U801-WIN
* RS232 cable, UPCB-01
3-2 Electrical Specification
s
Sensor type 2 ba
r
5 ba
r
10 ba
r
Max. Reso- Max. Reso- Max. Reso-
ran
g
elutionran
g
elution ran
g
elution
bar 2 0.002 5 0.005 10 0.01
Psi 29 0.02 72.5 0.1 145 0.2
Kg/cm 2 2.040 0.002 5.095 0.005 10.19 0.01
mm/Hg 1500 2 3750 5 7500 10
inch/Hg 59.05 0.05 147.6 0.1 295.2 0.2
meter/HF2 20.40 0.02 50.95 0.05 101.9 0.1
inch/HF2 802 1 2006 2 4010 5
Atmosphere 1.974 0.002 4.935 0.005 9.87 0.01
3

Sensor type 20 ba
r
50 ba
r
100 ba
r
Max. Reso- Max. Reso- Max. Reso-
ran
g
elutionran
g
elution ran
g
elution
bar 20 0.02 50 0.05 100 0.1
Psi 290 0.2 725 1 1450 2
Kg/cm 2 20.40 0.02 50.95 0.05 101.9 0.1
mm/Hg 15000 20 37500 50 75000 100
inch/Hg 590.5 0.5 1476 1 2952 2
meter/HF2 204.0 0.2 509.5 0.5 1019 1
inch/HF2 8020 10 20050 20 40100 50
Atmosphere 19.74 0.02 49.35 0.05 98.7 0.1
Sensor type 200 ba
r
400 ba
r
Max. Reso- Max. Reso-
ran
g
elutionran
g
elution
bar 200 0.2 400 0.5
Psi 2900 2 5800 5
Kg/cm 2 204.0 0.2 408.0 0.5
mm/Hg 150000 200 300000 500
inch/Hg 5905 5 11810 10
meter/HF2 2040 2 4075 5
inch/HF2 80200 100 160600 200
Atmosphere 197.4 0.2 394.5 0.5
4

4. FRONT PANEL DESCRIPTION
Fig. 1
4-1 Display 4-9 Sensor Input Socket
4-2 Power Button 4-10 RS-232 Output
4-3 Data Hold Button Terminal
4-4 " Max./Min. " Button 4-11 Port Connector of
4-5 Unit Button Pressure Sensor
4-6 Zero Button 4-12 Pressure Sensor
4-7 Sensor Type Button Main body
4-8 Battery Compartment/ 4-13 Plug of Pressure Sensor
Cover
5

5. SENSOR TYPE SELECTION
The meter can cooperate with optional 2, 5, 10, 20, 50, 100,
200 bar sensor, new calibration are not necessary when
change the new sensor .
Those different optional pressure sensor are :
* 2 bar pressure sensor, Model : PS100-2BAR
* 5 bar pressure sensor, Model : PS100-5BAR
* 10 bar pressure sensor, Model : PS100-10BAR
* 20 bar pressure sensor, Model : PS100-20BAR
* 50 bar pressure sensor, Model : PS100-50BAR
* 100 bar pressure sensor, Model : PS100-100BAR
* 200 bar pressure sensor, Model : PS100-200BAR
* 400 bar pressure sensor, Model : PS100-400BAR
When change the different sensor ( 2 Bar, 5 Bar, 10 Bar, 20
Bar, 50 Bar...... ) should according procedures as follow :
1) Power off the meter.
2)Use the finger to push the following 3 buttons
at the same time continuously, those buttons are :
* Data Hold Button ( 4-3 Fig. 1 )
* " Max./Min. " Button ( 4-4 Fig. 1 )
* Sensor Type Button ( 4-7 Fig. 1 )
6

Font panel
SENSOR
HOLD TYPE
MAX./MIN.
3) Not release the above 3 keys, , push the " Power Button "
( 4-2 , Fig. 1 ) once a while. all the LCD segment will lit.
Release the 3 buttons, the display will show the memorized
sensor type.
Bar
4) Push the " Sensor Type Button " ( 4-7, Fig. 1 ) can select
the different sensor type ( 2, 5, 10, 20, 50, 100, 200, 400 Bar )
.
Until the display show the desired sensor type, push the
the " Zero button " ( 4-6, Fig. 1 ) to enter the desired
sensor type. The new setting sensor type will memorize
into the circuit even power off.
5)Power off the meter, the sensor type selecting procedures
are finished.
7

6. MEASURING PROCEDURE
1)Plug in the " Plug of Pressure Sensor " ( 4-13, Fig. 1 ) to
meter's " Sensor Input Socket " ( 4-9, Fig. 1 )
2)Power on the meter by push the " Power Button " ( 4-2,
Fig. 1 )
3)Push the " Sensor Type Button " ( 4-7, Fig 1 ) to check if
the meter's sensor type is same as the external pressure senso
r
4)Push the " Unit Button " ( 4-5, Fig. 1 ) to select the unit (
Bar, Psi, Kg/cm 2 mm/Hg, inch/Hg, meter/HF2 ,
inch/HF2 , Atmosphere ).
5)Zero the meter by push the " Zero Button " ( 4-6, Fig. 1 ),
the display reading will change to zero value.
6) Connect the " Port Connector of Pressure Sensor "
( 4-11, Fig. 1 ) to the installation that intend to measure
the pressure value that into the sensor.
7)Apply the pressure, pressure meter will show the pressure
value.
8)Data Hold
During the measurement, pushing the " Data Hold
Button " ( 4-3, Fig. 1 ) will freeze the measured value &
display will indicate " HOLD " symbol.
* Push the "Data Hold Button" again to release the
data hold function.
9) Data Record ( Maximum, Minimum reading )
* The DATA RECORD function displays the maximum
and minimum readings. To start the DATA RECORD
function, press the " Max./Min. Button " ( 4-4, Fig. 1 )
once. " REC " symbol will appear on the LCD display.
8
Table of contents
Other MRC Measuring Instrument manuals