METER TEMPOS User manual

TEMPOS

i
TABLE OF CONTENTS
1. Introduction.............................................................................................. 1
2. System......................................................................................................... 2
2.1 Specifications............................................................................................2
2.2 TEMPOS Controller .................................................................................... 4
2.2.1 Main Menu .......................................................................................6
2.2.2 Take a Reading Screen ..................................................................... 7
2.2.3 Measurement Configuration Screen ................................................7
2.2.4 Stored Readings Menu.....................................................................9
2.2.5 Unattended Mode Screen .............................................................. 11
2.2.6 Device Configuration Screen.......................................................... 13
2.2.7 About Screen ................................................................................. 13
2.3 Sensors.................................................................................................... 14
2.3.1 KS-3............................................................................................... 14
2.3.2 TR-3 ............................................................................................... 15
2.3.3 SH-3............................................................................................... 15
2.3.4 RK-3............................................................................................... 15
3. Operation ................................................................................................. 16
3.1 Controller Configuration .......................................................................... 16
3.2 Measurement Configuration .................................................................... 17
3.3 Sensor Installation .................................................................................. 20
3.3.1 Rock or Cured Concrete (RK-3)....................................................... 21
3.3.2 Wet Cement ................................................................................... 21
3.3.3 Solid Material (TR-3)...................................................................... 22
3.3.4 Insulation (KS-3)............................................................................ 22
18215-05
8.21.2020

ii
3.4 Take a Reading......................................................................................... 22
3.5 Saving and Viewing a Reading.................................................................. 24
3.6 Interfacing with TEMPOS Utility............................................................... 25
3.6.1 Install TEMPOS Utility.................................................................... 25
3.6.2 Download Data............................................................................... 26
3.6.3 Update Firmware Version............................................................... 27
4. Theory........................................................................................................ 29
4.1 Dual-Needle Algorithm ............................................................................ 30
4.2 Single-Needle Algorithm ......................................................................... 31
4.3 Algorithm for the Insulation Mode ........................................................... 32
4.4 Volumetric Specific Heat for Insulation Thermal Conductivity
Measurements....................................................................................... 33
4.5 Understanding the SYX Value .................................................................... 34
5. Service....................................................................................................... 35
5.1 Sensor Maintenance and Verification ...................................................... 35
5.1.1 Verification withtheKS-3,TR-3,orRK-3....................................... 35
5.1.2 Verification with the SH-3.............................................................. 37
5.2 Controller Maintenance ........................................................................... 37
5.3 Troubleshooting ....................................................................................... 38
5.4 Customer Support.................................................................................... 39
5.5 Terms and Conditions .............................................................................. 39
References .................................................................................................... 40
Index ................................................................................................................. 42

x 5
x 3
AT TENTION!
IMPORTANT DOCUMENTS ENCLOSED:
Safety Data Sheets (SDS)
Certificate of Analysis

1
TEMPOS
1. INTRODUCTION
Thank you for purchasing the TEMPOS Thermal Properties Analyzer from METER Group.
This manual will help the user understand and use the TEMPOS controller to the best of its
capability. Verify all components are included and appear in good condition:
• TEMPOS controller
• Carrying case
• Mini-USB data download cable
• 5 AA alkaline batteries (installed in TEMPOS controller)
• Glycerin verification standard
• Sensor positioning jigs
• Thermal grease
• Sensors (ordered with device)
• Pilot pins (if TR-3 sensor ordered)
• Drill bits (if TR-3 sensor ordered)
• Extra septum
• SH-3 needle guides (if SH-3 sensor ordered)
• SH-3 Delrin®verification block (if SH-3 sensor ordered)
The RK-3 Rock Sensor kit includes the following items and is available separately by
contacting Customer Support:
• 5/32-in (4-mm) drill bit
• RK-3 sensor
• Arctic alumina
• 1-m cable
Custom cable lengths of 2,3,5,and 10 m are available upon request.

2
SYSTEM
2. SYSTEM
This section describes the specifications and components of the TEMPOS. The system
comprises the handheld device (Section2.2) and compatible four sensors (Section2.3).
2.1 SPECIFICATIONS
MEASUREMENT SPECIFICATIONS
KS-3 (6-cm [small] single needle)
Conductivity
Range 0.02–2.00 W/(m • K)
Accuracy ±10% from 0.2–2.0 W/(m • K)
Resistivity
Range 50–5,000 °C • cm/W
TR-3 (10-cm [large] single needle)
Conductivity
Range 0.1–4.0 W/(m • K)
Accuracy ±10% from 0.1–4.0 W/(m • K)
Resistivity
Range 25–1,000 °C • cm/W
SH-3 (3-cm dual needle)
Conductivity
Range 0.02–2.00 W/(m • K)
Accuracy ±10% from 0.02–2.0 W/(m • K)
Diffusivity
Range 0.1–1.0 mm2/s
Accuracy ±10% at conductivity above 0.2 W/(m • K)
±0.02 W/(m • K) from 0.10–0.20 W/(m • K)
Volumetric Specific Heat Capacity
Range 0.5–4.0 MJ/m3
Accuracy ±10% at conductivities above 0.1 W/(m • K)

3
TEMPOS
RK-3 (6-cm [thick] single needle)
Conductivity
Range 0.1–6.0 W/(m • K)
Accuracy ±10% from 0.1–6.0 W/(m • K)
Resistivity
Range 17–1,000 °C • cm/W
PHYSICAL CHARACTERISTICS
Controller Dimensions
Length 18.5 cm (7. 28 in)
Width 10 cm (3.94 in)
Height 3.5 cm (1.38 in)
Carrying Case Dimensions
Length 37 cm (14.57 in)
Width 30 cm (11.81 in)
Height 10.5 cm (4.13 in)
Display Dimensions
Width 5.5 cm (2.17 in)
Height 4.0 cm (1.57 in)
Sensor Needle Dimensions
KS-3 1.3 mm diameter ×60 mm length
TR-3 2.4 mm diameter ×100 mm length
SH-3 1.3 mm diameter ×30 mm length
6 mm spacing between needles
RK-3 3.9 mm diameter ×60 mm length
Battery Capacity
5 AA alkaline batteries

4
SYSTEM
Battery Life
>250 high-power measurements
Read Modes
Manual and unattended
Controller Operating Temperature Range
Minimum 0 °C
Maximum +50 °C
Sensor Operating Temperature Range
Minimum –50 °C
Maximum +150 °C
Data Storage
2,048 measurements in flash memory (both raw and processed data are stored
fordownload)
Connector Types
DB-15 (to sensors)
Mini-USB to USB (to computer)
COMPLIANCE
Manufactured under ISO 9001:2015
EN 61326-1:2013
EN 55022/CISPR 22
2.2 TEMPOS CONTROLLER
The TEMPOS controller is a handheld device to read and save the TEMPOS sensor
measurements. The unit has a DB-15 pin receiver to connect to sensors. The other port on
the controller is a mini-USB port for downloading data (Section3.6). The TEMPOS controller
requires five alkaline AA batteries (included).
The TEMPOS controller has a POWER button, a BACK button, and a central D-pad. The
POWER button (Figure1) turns the TEMPOS controller on and off. To completely power down
the unit, quickly press the POWER button and release. For a hard reset of the device, push
and hold the POWER button for 5 s.

5
TEMPOS
Pressing the BACK button (Figure1) moves the cursor back to the previous screen. When
it is pressed multiple times, the cursor moves back to the Main menu. Changes are
automatically saved.
The D-pad selects configurations or options in the TEMPOS controller (Figure1).
• The CENTER button (Figure1) serves as the Select or Enter function.
• The UP, DOWN, RIGHT, and LEFT buttons (Figure1) are active when an icon or text on the
display screen is highlighted in red. These arrows allow the user to scroll within a field or to
select a field before pressing the CENTER button.
The device automatically goes to sleep when not used for more than 5 min. While in
unattended mode, the screen will turn off after 5 min, but scheduled readings will continue.
D-pad
BACK button
LED screen
CENTER button
RIGHT button
LEFT button
DOWN button
UP button
POWER button
DB-15
connection port
Mini-USB port
Figure1 TEMPOS controller

6
SYSTEM
Every menu screen (Figure2) contains a header bar that displays (from left to right) the
current reading mode, time, current sensor pairing, and battery status.
Header
bar
Reading
mode Time
Current
sensor
Battery
status
Figure2 TEMPOS screen components
2.2.1 MAIN MENU
The Main menu is the starting point for all of the firmware applications within the device.
Measurement
Configuration
Unattended
Mode
Stored Readings
Device Configuration
About
Take a Reading
Figure3 Main menu
There are six icons in the Main menu that represent the six main functions of the TEMPOS.
• Take a Reading (Section2.2.2)
• Measurement Configuration (Section2.2.3)
Table of contents
Other METER Measuring Instrument manuals

METER
METER ACCUPAR LP-80 User manual

METER
METER AQUALAB PAWKIT User manual

METER
METER G3 User manual

METER
METER MW04 User manual

METER
METER PROCHECK User manual

METER
METER ATMOS 22 User manual

METER
METER SATURO User manual

METER
METER TEROS 54 User manual

METER
METER AQUALAB VSA User manual

METER
METER ATMOS 22 User manual

METER
METER AQUALAB TDL User manual

METER
METER AQUALAB User manual

METER
METER APOGEE SQ-521 User manual

METER
METER SI-400 Series User manual

METER
METER AQUALAB TDL User manual

METER
METER TEROS 32 User manual

METER
METER AQUALAB PAWKIT User manual

METER
METER APOGEE SU-221 User manual

METER
METER WP4C User manual

METER
METER SC-1 User manual