Kobold ZOE User manual

Operating Manual
for
Flow-Totalizer
Model: ZOE

ZOE
Page 2 ZOE K10/0523
1. Table of Contents
1.Table of Contents ......................................................................................... 2
2.Note .............................................................................................................. 3
3.Instrument Inspection ................................................................................... 3
4.Regulation Use ............................................................................................. 4
5.Environment ................................................................................................. 4
6.Instrument / Functions overview ................................................................... 5
7.Electrical connections ................................................................................... 5
7.1Cable entry for housing option -K ........................................................ 5
7.2Overview of Terminals ZOE-ZX with Supply option B and 3 ............... 6
7.3Power Supply ...................................................................................... 7
7.4Sensor Inputs ...................................................................................... 8
7.5Control Input ...................................................................................... 14
7.6Pulse Output ..................................................................................... 16
8.Operating and Menu Structure ................................................................... 17
8.1Overall ............................................................................................... 17
8.2Measuring Mode ................................................................................ 17
8.3Menu Mode ....................................................................................... 18
9.Instrument Parameters ............................................................................... 20
9.1End of instrument parameterization ................................................... 20
9.2Overview of menu functions/ instrument parameters ........................ 21
9.3Signal ................................................................................................ 23
9.4Scaling .............................................................................................. 24
9.5Rate ................................................................................................... 26
9.6Counter ............................................................................................. 27
9.7Pulse output (only with ZOE-ZE Supply option 3) ............................. 29
9.8User service ...................................................................................... 30
9.9Factory service .................................................................................. 30
9.10Information ........................................................................................ 31
10.Technical Information ................................................................................. 31
11.Order Codes ............................................................................................... 31
12.Dimensions ................................................................................................. 31
13.Disposal ...................................................................................................... 32
14.EU Declaration of Conformance ................................................................. 33
15.UK Declaration of Conformity ..................................................................... 34
Manufactured and sold by:
Kobold Messring GmbH
Nordring 22-24
D-65719 Hofheim
Tel.: +49(0)6192-2990
Fax: +49(0)6192-23398
E-Mail: [email protected]
Internet: www.kobold.com

ZOE
ZOE K10/0523 Page 3
2. Note
Please read these operating instructions before unpacking and putting the unit into
operation. Follow the instructions precisely as described herein.
The instruction manuals on our website www.kobold.com are always for currently
manufactured version of our products. Due to technical changes, the instruction
manuals available online may not always correspond to the product version you have
purchased. If you need an instruction manual that corresponds to the purchased product
version, you can request it from us free of charge by email (in[email protected]) in PDF
format, specifying the relevant invoice number and serial number. If you wish, the
operating instructions can also be sent to you by post in paper form against an applicable
postage fee.
Operating instructions, data sheet, approvals and further information via the QR code
on the device or via www.kobold.com
The devices are only to be used, maintained and serviced by persons familiar with these
operating instructions and in accordance with local regulations applying to Health &
Safety and prevention of accidents.
When used in machines, the measuring unit should be used only when the machines
fulfil the EC-machine guidelines.
3. Instrument Inspection
Instruments are inspected before shipping and sent out in perfect condition.
Should damage to a device be visible, we recommend a thorough inspection of the
delivery packaging. In case of damage, please inform your parcel service / delivery
agent immediately, since they are responsible for damages during transit.
Scope of delivery:
The standard delivery includes:
Flow counter/- unit/-- in plastic- universal housing with wall or pipe mounting set
Model: ZOE-ZX with universal housing ‘K’
OR
Oval gear flow meter DON- with electronics option –ZE/ZB in compact version
Model: ZOE-ZX with universal housing ‘M’
Battery 3.6 V Lithium size AA for battery mode

ZOE
Page 4 ZOE K10/0523
4. Regulation Use
The electronic units ZOE-ZX are specifically designed for the calculation, display and
transfer of calculations and flow rates of flow meters with pulse or frequency outputs.
The instruments display flow rate, day counter (resettable) and total counter in the
operator-selected units. A menu guides you through the programming of the device that
largely eliminates the requirement of constant usage of operating manual. All user-
specific program settings are retained even when changing the battery.
A trouble-free operation of the device is only guaranteed if all instructions in this manual
are complied. We do not accept any liability for damage caused by failure to follow these
instructions.
5. Environment
The electronic options ZOE-ZX are weather resistant and adequately reflect IP66/67
(NEMA 4X). The electronics are housed in a UV-resistant, glass-filled nylon housing
with stainless steel screws and FPM seals.
The instruments are suitable for harsh indoor or outdoor environments and comply with
EU Directive 2014/30/EU (Electromagnetic Compatibility).

ZOE
ZOE K10/0523 Page 5
6. Instrument / Functions overview
7. Electrical connections
7.1 Cable entry for housing option -K
Up to 3 cable entries (M20x1.5 or ½ "NPT) are available for electric connection in case
of electronics with plastic housing. To use these cable inlets, the existing factory
protection caps must be broken with a tool (e.g. screwdriver) and a suitable cable gland
should be screwed in. The cable glands are not included in the delivery.
Eruption of cable inlets
Function ZOE-ZExxF3 ZOE-ZBxxFB
Dual counting
function x x
Supply voltage
DC-supply x -
Battery operation x x
Sensor supply (only
with external supply) 8 V -
Electrical outputs (only with external
supply)
Pulse output x -
LCD Display
Selectable units x X
Decimal point x X
Accumulated totalizer x X
Resettable totalizer x X
Linearization x X
Rate display x X
Backlight x -

ZOE
Page 6 ZOE K10/0523
7.2 Overview of Terminals ZOE-ZX with Supply option B and 3
Supply option B
(Battery supply - either 1 x 3.6 V or 2 x 1.5 V)
Supply option 3
(external DC supply or depending on the used sensor with battery)

ZOE
ZOE K10/0523 Page 7
7.3 Power Supply
Depending on functionality and features, the electronics offer different possibilities for
power supply:
Options ZOE-ZExxx3xx: Battery and ext. DC-Supply
Options ZOE-ZBxxxBxx Battery operation
7.3.1 Storing the counter readings
The storage of meter readings is carried out after each measurement cycle in the internal
FRAM. If the power is interrupted and re-applied, than the meter reading revert to the
last saved values.
7.3.2 External DC-Supply
When electronic units are supplied with external DC voltage, all functions are available
i.e. Pulse output, display backlight and sensor supply can be used as needed.
If the device is taken out of operation and not used for longer periods,
the battery must be removed. Otherwise, the device is always supplied
by the battery and remains active. As a result, the battery can get
discharged.
7.3.3 Battery operation (ZOE-ZB with supply option B)
The option ZOE-ZX can also be powered by a battery. In battery mode, the device
function scope is relatively limited:
Pulse output is not available.
The backlight of the display is switched off and cannot be turned on.
Only passive sensors may be used like reed switches, as they require no
additional power supply. Usage of induction coils reduces the battery life. Other
sensors, which require a sensor power for operation, are also not suitable for
battery operation.
The supplied battery type 3.6 V AA Lithium (2200 mAh) should be inserted in the battery
holder on the back side of the electronic (correct polarity is important!).
The following battery type is recommended as a replacement for the supplied battery:
a) 3.6 V lithium, size AA, capacity at least 2200 mAh, IEC type CR14505
For example: EVE type ER14505M, SAFT LS14500, Emmerich ER 14505, VARTA
CR 14505
b) 2 x alkali, size AA, IEC type LR6
Battery life duration: The achievable battery life is dependent on various factors:
On the total number of detected input pulses and the input frequency(higher
frequencies reduce the battery life)
On the environmental conditions - low temperatures reduce the usable battery
capacity.

ZOE
Page 8 ZOE K10/0523
7.4 Sensor Inputs
7.4.1 Active pulse signal
Power Supply: External DC-Supply
Signal input setting: „ACTIVE SIGNAL“
Wiring for ZOE-ZE with Supply option 3:
When connecting active pulse signals, the device can also be supplied with battery.
Wiring for ZOE-Z with Supply option B:

ZOE
ZOE K10/0523 Page 9
7.4.2 Hall Sensor, NPN- and PNP-Sensors
Power supply: only external DC-supply
Signal input setting: „HALL“
Signal input setting: „NPN“
Signal input setting: „PNP“
Wiring for ZOE-ZE:

ZOE
Page 10 ZOE K10/0523
7.4.3 Reed switch
Power supply: External DC supply, battery operation or
Signal input setting: „REED “
Wiring for ZOE-ZE with Supply option 3:
Wiring for ZOE-Z with Supply option B:
When using a reed contact as a sensor, version ZOE-ZE can also be supplied with
battery (no electrical output).
Table of contents
Other Kobold Measuring Instrument manuals

Kobold
Kobold BGN User manual

Kobold
Kobold MAS Series User manual

Kobold
Kobold OMH-15 User manual

Kobold
Kobold DRB Series User manual

Kobold
Kobold KSM-**001 User manual

Kobold
Kobold SFL User manual

Kobold
Kobold DRB Series User manual

Kobold
Kobold DF KL Series User manual

Kobold
Kobold HND-P215 User manual

Kobold
Kobold NBK-03 User manual

Kobold
Kobold HND-P105 User manual

Kobold
Kobold KEL Series User manual

Kobold
Kobold KSK User manual

Kobold
Kobold DAG-A1V User manual

Kobold
Kobold NBK-19 User manual

Kobold
Kobold DAG-M12 User manual

Kobold
Kobold ZUB-MANS-KON1/2 User manual

Kobold
Kobold DUC-MF1 User manual

Kobold
Kobold MIM Series User manual

Kobold
Kobold DW Series User manual