Hach DR 6000 Quick manual

DOC022.97.90368
DR 6000
11/2018, Edition 4
Basic User Manual en
Manual básico del usuario es
Manuel d'utilisation de base fr
基本ユーザーマニュアル ja
기본 사용 설명서 ko
Manual do utilizador básico pt
基本用户手册 zh

English .................................................................................................................................................................................................. 3
Español ............................................................................................................................................................................................. 31
Français ........................................................................................................................................................................................... 59
英語 .................................................................................................................................................................................................... 89
한국어 .............................................................................................................................................................................................. 117
Português ....................................................................................................................................................................................... 143
英语 ................................................................................................................................................................................................... 171

English 3
English
Technical data
Changes reserved!
Performance specifications
Operating mode Transmittance (%), Absorbance and Concentration
Source lamp Deuterium lamp (UV) and halogen lamp (visual
range)
Wavelength range 190–1100 nm
Wavelength Accuracy ± 1 nm (wavelength range 200–900 nm)
Wavelength
reproducibility < 0.1 nm
Wavelength resolution 0.1 nm
Wavelength calibration Automatic
Wavelength selection Automatic, based on method selection
Scanning speed 900 nm/min (in 1-nm steps)
Spectral bandwidth 2 nm (1.5–2.9 nm at 656 nm, 1 nm for D2 line)
Photometric measuring
range ± 3 Abs (wavelength range 200–900 nm)
Photometric accuracy 5 mAbs at 0.0–0.5 Abs
< 1% at 0.50–2.0 Abs at 546 nm
Photometric linearity < 0.5% to 2 Abs
1% at > 2 Abs with neutral glass at 546 nm
Stray light KI solution at 220 nm
< 3.3 Abs / < 0.05%
Photometric drift against
blank reading
(30-min baseline stable)
190–199 nm +/- 0.0100 Abs
200–349 nm +/- 0.0054 Abs
350–899 nm +/- 0.0034 Abs
900–1100 nm +/- 0.0100 Abs
Long-term stability Zero point at 546 nm for 10 hours 0.0034 Abs
Data log
5000 measurement values (result, date, time, sample
ID, user ID)
50 scans, 50 time scans
User programs 200
Physical and environmental specifications
Width 500 mm (19.69 in)
Height 215 mm (8.46 in)
Depth 460 mm (18.11 in)
Weight 11 kg (24.25 lb)
Ambient operating
requirements
10–40 °C (50–104 °F), maximum 80% relative
humidity
(without condensate formation)
Ambient storage
requirements
–25–60 °C (–13–140 °F), maximum 80% relative
humidity
(without condensate formation)
Additional technical data
Power connection 100–240 V/50–60 Hz
Power consumption 150 VA
Fuse T 2A H; 250 V (2 units)
Interfaces
Use only shielded cable with maximum length of 3 m:
2x USB type A
1x USB type B
Use only shielded cable (for example STP, FTP, S/
FTP)
with maximum length of 20 m:
1x Ethernet
Housing rating IP20 with closed cell compartment cover
Performance specifications

English 4
General information
Safety notes
Read the entire user manual carefully before you unpack, set up or
operate the device. Observe all danger and warning notes. Non-
observance could lead to serious injury of the operator or to damage to
the device.
To make sure that the protection provided by this instrument is not
impaired, do not use or install this instrument in any manner other than
that specified in these operating instructions.
Note: Information that supplements aspects from the main text.
Protection class Class I
This product has been tested to the requirements of
CAN/CSA-C22.2 No. 61010-1, second edition,
including Amendment 1, or a later version of the
same standard incorporating the same level of testing
requirements.
Pollution Degree 2
Installation Category II
Maximum Altitude 2000 m (6560 ft)
Performance specifications
DANGER
Indicates a potentially or imminently hazardous situation that, if not avoided, can
result in death or serious injury.
WARNING
Indicates a potentially or imminently dangerous situation that, if it is not avoided,
can lead to death or to serious injuries.
CAUTION
Indicates a possible dangerous situation that can have minor or moderate injuries
as the result.
WARNING
Indicates a situation that, if it is not avoided, can lead to damage to the device.
Information that requires special emphasis.

English 5
Warning labels
Observe all marks and labels that are attached to the device. Non-
observance may result in personal injury or damage to the device. For
symbols attached to the device, corresponding warning notes are found
in the user manual.
Safety around source lamps
The source lamps are operated at high temperatures.
To avoid the risk of electrocution, make sure the instrument is
disconnected from the power source before changing the lamps.
RFID module (not available on all models)
RFID technology is a radio application. Radio applications are subject to
national conditions of authorization. The use of the DR 6000 (model with
RFID module) is currently permitted in the following countries: EU, CH,
NO, HR, RS, MK, TR, CY, US, CA, AU, NZ. We point out that the use of
the DR 6000 (model with RFID module) outside of the named regions
may contravene national law. The manufacturer reserves the right also
to obtain authorization in other countries. For questions about use in
your area, please contact your distributor.
This symbol may be attached to the device and references the
operation- and/or safety notes in the user manual.
This symbol on the device is an indication of hot surfaces.
Electrical equipment marked with this symbol may as of August 12,
2005 Europe-wide no longer be disposed of in unsorted house or
industrial waste. According to valid provisions (EU Directive 2002/96/
EC), from this point consumers in the EU must return old electrical
devices to the manufacturer for disposal. This is free for the
consumer.
Note: Contact the manufacturer or supplier to find out how
you can return worn out devices, electrical accessories
supplied by the manufacturer and all auxiliary articles for
correct disposal or recycling.
WARNING
The manufacturer is not responsible for any damages due to misapplication or
misuse of this product including, without limitation, direct, incidental and
consequential damages, and disclaims such damages to the full extentpermitted
under applicable law.
The user is solely responsible to identify critical application risks and install
appropriate mechanisms to protect processes during a possible equipment
malfunction.
CAUTION
Health hazard caused by ozone.
Hazardous levels of ozone can be generated when the UV lamp is not cooled.
WARNING
Health hazard caused by UV light.
UV-Licht can cause eye and skin damage. Protect eyes and skin from direct
exposure to UV light.
Do not look directly at an energized lamp without UV safety glasses.
CAUTION
Burn hazard, allow the lamp(s) to cool down for at least 30 minutes before they
are serviced/replaced.

English 6
The DR 6000 contains an RFID module for the reception and
transmission of information and data. The RFID module operates with a
frequency of 13.56 MHz.
Follow the following safety information, in addition to any local guidelines
in force.
Safety information for the correct use of the instrument:
•Do not operate the instrument in hospitals or comparable
establishments in the vicinity of medical equipment, such as pace
makers or hearing aids.
•Do not operate the instrument near highly flammable substances,
such as fuels, highly combustible chemicals and explosives.
•Do not operate the device near combustible gases, vapors or dust.
•Do not vibrate or jolt the instrument.
•The instrument can cause interference in immediate proximity to
televisions, radios and computers.
•Do not open the instrument.
•Guarantee is voided if the instrument is not used in accordance with
the guidelines present in this document.
Certification (integrated RFID module)
FCC ID: YUH-QR15HL
IC: 9278A-QR15HL
This device complies with Part 15 of the FCC rules and Industry Canada
license exempt RSS standard(s).
Operation is subject to the following two conditions:
1. this device may not cause interference, and
2. this device must accept any interference, including interference that
may cause undesired operation of the device.
Changes or modifications to this equipment not expressly approved by
the party responsible for compliance could void the user's authority to
operate the equipment.
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC rules. These limits
are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be
required to correct the interference at their expense. The following
techniques can be used to reduce interference problems:
1. Disconnect the equipment from its power source to verify that it is
or is not the source of the interference.
2. If the equipment is connected to the same outlet as the device
experiencing interference, connect the equipment to a different
outlet.
3. Move the equipment away from the device receiving the
interference.
4. Reposition the receiving antenna for the device receiving the
interference.
5. Try combinations of the above.
Chemical and Biological Safety
Normal operation of this device may require the use of chemicals or
samples that are biologically unsafe.
WARNING
The spectrophotometer may not be used in dangerous environments.
The manufacturer and its suppliers reject any express or indirect guarantee for
use with high-risk activities.
DANGER
Potential danger with contact with chemical/biological substances.
Working with chemical samples, standards and reagents can be dangerous.
Make yourself familiar with the necessary safety procedures and the correct
handling of the chemicals before use and read and follow all relevant safety data
sheets.

English 7
•Observe all cautionary information printed on the original solution
containers and safety data sheets prior to their use.
•Dispose of all consumed solutions in accordance with the local and
national regulations and laws.
•Select the type of protective equipment suitable to the concentration
and quantity of the dangerous material being used.
Product overview
The DR 6000 is a UV-VIS-spectrophotometer with a wavelength range
of 190 to 1100 nm. The visible spectrum (320 to 1100 nm) is covered by
a halogen lamp and a deuterium lamp produces the light in the
ultraviolet spectrum (190 to 360 nm).
The instrument is supplied with a complete range of application
programs and supports several languages.
The DR 6000 spectrophotometer contains the following programs and
operating modes:
•Stored programs (pre-installed tests)
•Barcode Programs
•User Programs
•Favorites
•Single Wavelength
•Multi Wavelength
•Wavelength Scan
•Time course
The DR 6000 spectrophotometer provides digital readouts of
concentration, absorbance and percent transmittance.
When selecting a user-generated or programmed method, the menus
and prompts serve to direct the user through the test.
This menu system can also produce reports, statistical evaluations of
generated calibration curves and reports on instrument diagnostic
checks.
Installation
Unpacking the instrument
The DR 6000 spectrophotometer package is supplied with the following
items:
•DR 6000 spectrophotometer
•Dust cover
•USB dust cover, fitted as standard
•Power cord for US and EU (when shipped to China power cord for
CN)
•Universal cell adapter
•Operator RFID tag (not available on all models)
•1 Inch cells, matched pair
•Basic DR 6000 user manual, LINK2SC user manual
.
Note: If any of these items are missing or damaged, please contact the
manufacturer or a sales representative immediately.
Operating environment
Observe the following points so that the device functions faultlessly and
thus has a long service life.
WARNING
Electrical dangers and fire hazard.
Only use the supplied power cable.
Only qualified experts may perform the tasks described in this section of the
manual, while adhering to all locally valid safety regulations.
WARNING
Removable power cables must not be replaced with inadequately dimensioned
power cables.

English 8
•Place the device securely on an even surface. Push no objects
under the device.
•Position the device so that the power cord is not impaired.
•The ambient temperature must be 10–40 °C (50–104 °F).
•The relative humidity should be less than 80%; moisture should not
condense on the instrument.
•Leave at least a 15 cm clearance at the top and on all sides for air
circulation to avoid overheating of electrical parts.
•Do not use or store the device in extremely dusty, humid or wet
places.
•Keep the surface of the instrument, the cell compartment and all
accessories clean and dry at all times. Immediately remove
splashes or spilt materials on or in the instrument (refer to
Maintenance, page 26).
Front and back view
Figure 1 Front view
NOTICE
Protect the instrument from extreme temperatures from heaters, direct sunlight
and other heat sources.
1USB port type A 5Touch screen
2Cell compartment cover 6Power save key
3Lamp compartment cover 7RFID module (not available on all
models)
4Fan outlet

English 9
Figure 2 Back view Power connections
1. Plug the power cable into the back of the instrument (Back view,
page 9).
2. Insert the plug of the power cable into a grounded mains socket
(100–240 V~ / 50–60 Hz).
3. Switch the power button to "On" to turn on the instrument (Back
view, page 9).
1On/off switch 4USB port type B
2Socket for power cable 5USB port type A
3Ethernet port 6Filter pad cover
NOTICE
Use only a grounded socket for the connection of this device to the power supply.
If you are not sure if the sockets are grounded, have this checked by a qualified
electrician. The power plug serves in addition to the power supply to isolate the
device quickly from the power source where necessary. During the disconnection
from the power source it must be made sure that the correct power plug is pulled
(for example by labeling the sockets). This is recommended for long-term storage
and can prevent potential dangers in the event of a fault. Therefore make sure
that the socket to which the device is connected is easy to reach by each user at
all times.
WARNING
Electrical dangers and fire hazard.
Only use the supplied power cable.

English 10
How to position the universal cell adapter
1. Open the cell compartment.
2. Raise the universal cell adapter by approx. 1 cm.
3. Rotate the universal cell adapter such that the guide of the required
cell profile faces left toward the cell compartment (1).
4. Press the universal cell adapter down until it snaps into place.
Figure 3 How to position the universal cell adapter
Startup
Switch on the instrument, startup process
1. Connect the power cable to a power socket.
2. Switch on the instrument via the power switch on the back.
3. The device automatically starts an approximately 45 second long
startup process. The display shows the logo of the manufacturer. At
the end of the startup process, a startup melody is heard.
Note: Wait approximately 20 seconds before switching on again so as
not to damage the electronics and mechanics of the instrument.
Language selection
The DR 6000 software includes several language options. The first time
the instrument is switched on, the language selection screen will be
shown automatically after the startup process.
1. Select the required language.
2. Press OK to confirm the language selection. The self-check will
then start automatically.
Other manuals for DR 6000
3
Table of contents
Languages:
Other Hach Measuring Instrument manuals

Hach
Hach LANGE Pocket Colorimeter II User manual

Hach
Hach sensION+ MM150 User manual

Hach
Hach Lange SensION+ MM 378 User manual

Hach
Hach QbD1200+ User manual

Hach
Hach TitraLab Quick manual

Hach
Hach TitraLab User manual

Hach
Hach pHD Sensor User manual

Hach
Hach 1735 TRO User manual

Hach
Hach H160 User manual

Hach
Hach sension 4 User manual

Hach
Hach 5500sc SiO2 User manual

Hach
Hach AMTAX sc User manual

Hach
Hach CL17sc User manual

Hach
Hach POLYMETRON 8810 ISE Quick manual

Hach
Hach NITRATAX plus sc User manual

Hach
Hach A1000 Quick manual

Hach
Hach orbisphere C1100 User manual

Hach
Hach Hach SL1000 Quick manual

Hach
Hach 51 Series User manual

Hach
Hach 8520600 User manual