Hach APA 6000 User manual

DOC023.97.80365
APA 6000
05/2013, Edition 1
Installation
Installation
Instalación

English...................................................................................................................................................................................................3
Français..............................................................................................................................................................................................21
Español...............................................................................................................................................................................................40
2

Table of contents
Specifications on page 3
General information on page 5
Installation on page 10
Specifications
Specifications are subject to change without notice.
Table 1 General specifications
Specification Details
Dimensions (W x D x
H)
626.11 x 527.05 x 522.73 mm (24.65 x 20.75 x
20.58 in.)
Enclosure Rating: UL Type 4X (indoor), IEC 529 (IP 66) when air
purge is used and the door is closed and latched
Material: PC/ABS case, PC door, PC hinges and
latches, 316 SST hardware
Weight 22.4 kg (49.3 lb) dry, 28.9 kg (63.7 lb) wet with full
analyzer bottles1 (approximately)
Mounting Wall or bench
Protection class I
Pollution degree 2
Installation category II
Power requirements 100–240 VAC, 50/60 Hz, 100 VA
Connection: 18 to 14 AWG wire, 18 AWG stranded
recommended
Operating temperature 5 to 50 °C (41 to 122 °F); best performance: 5 to 35 °C
(41 to 95 °F)
Operating humidity 5 to 95% relative humidity, non-condensing
Maximum altitude 2000 m (6560 ft)
Table 1 General specifications (continued)
Specification Details
Recorder outputs Two 4–20 mA outputs applicable for recorders; load
impedance: 675 Ω maximum; 130 VAC isolation from
earth ground
Connection: 22 to 14 AWG wire, 22 to 20 AWG
recommended, twisted pair shielded wire
Alarm relay outputs Two dry contact SPDT relays, not powered, each rated
at 5 A resistive, 240 VAC maximum
Connection: 18 to 14 AWG wire, 18 AWG stranded
recommended
Analyzer bottles 1 liter, high-density polyethylene with polypropylene
caps
Fuses Two, 1.6 A, 250 V, 5 mm x 20 mm
External plumbing
connections
Sample lines: 6.35 mm (0.25-in.) OD push-in fitting for
poly tubing
Chemical drain (drain block): 12.7 mm (0.5-in.) ID barb
fitting for hose
Case drain: 25.4 mm (1-in.) ID for hose
Bottle enclosure drains: 9.53 mm (0.375-in.) ID hose
Air purge line: 6.35 mm (0.25-in.) OD push-in fitting for
poly tubing
Sample pressure No minimum or maximum requirement
Sample flow rate 100–2000 mL/minute; 500–1000 mL/minute
recommended
Sample temperature 5 to 50 °C (41 to 122 °F)
Sample particle size 0.5 µm maximum; sample goes through a 0.5 µm filter
in the sample conditioning block before analysis
Number of sample
streams
1; optional sample sequencing kit adds a second
sample stream, sample sequence is programmable
Node-to-node distance 400 m (1320 ft) maximum between analyzers
English 3

Table 1 General specifications (continued)
Specification Details
Air purge 15 scfh (7 L/min), dry instrument air, inert gas
Certifications Certified to UL and CSA by ETL, CE
1Six 1-liter bottles of water = 6 kg. The small amount of fluids in the analyzer =
0.5 kg. Add another 0.5 kg for chemicals that weigh more than water.
Table 2 Measurement specifications (part 1 of 2)
Specification Alkalinity Ammonia LR Ammonia/
Monochloramine
Light source Class 1M LED,
peak wavelength
600 nm
Class 1M LED,
peak wavelength
650 nm
Class 1M LED,
peak wavelength
650 nm
Parameters
measured
Total (T) alkalinity
Phenolphthalein
(P) alkalinity
Hydroxide
alkalinity
Carbonate
alkalinity
Bicarbonate
alkalinity
Free ammonia1Total ammonia,
monochloramine
Measurement
range
T alkalinity:
1–1000 mg/L as
CaCO3
P alkalinity:
5–1000 mg/L as
CaCO3
0.02–2 mg/L as N 0.1–10 mg/L as
Cl2
Accuracy2±5% or ±1.0 mg/L
(the larger value)
±5% or
±0.02 mg/L (the
larger value)
±5% or
±0.10 mg/L (the
larger value)
Precision/
Repeatability
±3% or ±0.6 mg/L
(the larger value)
±3% or
±0.01 mg/L (the
larger value)
±3% or
±0.05 mg/L (the
larger value)
Table 2 Measurement specifications (part 1 of 2) (continued)
Specification Alkalinity Ammonia LR Ammonia/
Monochloramine
Response time < 10 minutes3< 5 minutes3< 5 minutes3
Cycle time
(average)
8 minutes 6.2 minutes 6.2 minutes
Minimum
detection limit
≤ 0.10 mg/L ≤ 0.01 mg/L ≤ 0.05 mg/L
1The ammonia analyzer measures background monochloramine during
calibration only.
2Based on a calibration frequency of once a day
3For a 90% response to a step change at the sample inlet and one sample
stream
Table 3 Measurement specifications (part 2 of 2)
Specification Hardness LR Hardness HR
Light source Class 1M LED, peak
wavelength 520 nm
Class 1M LED, peak
wavelength 600 nm
Parameters measured Total hardness Total hardness
Measurement range 0.05–10 mg/L as CaCO310–1000 mg/L as CaCO3
Accuracy1±5% or ±0.05 mg/L (the
larger value)
±5% or ±2 mg/L (the larger
value)
Precision/ Repeatability ±3% or ±0.03 mg/L (the
larger value)
±5% or ±2 mg/L (the larger
value)
Response time < 5 minutes2< 17 minutes2
Cycle time (average) 4 minutes 8.2 minutes
Minimum detection limit 0.05 mg/L 10 mg/L
1Based on a calibration frequency of once a day
2For a 90% response to a step change at the sample inlet and one sample
stream
4 English

General information
In no event will the manufacturer be liable for direct, indirect, special,
incidental or consequential damages resulting from any defect or
omission in this manual. The manufacturer reserves the right to make
changes in this manual and the products it describes at any time, without
notice or obligation. Revised editions are found on the manufacturer’s
website.
Safety information
NOTICE
The manufacturer is not responsible for any damages due to misapplication or
misuse of this product including, without limitation, direct, incidental and
consequential damages, and disclaims such damages to the full extent permitted
under applicable law. The user is solely responsible to identify critical application
risks and install appropriate mechanisms to protect processes during a possible
equipment malfunction.
Please read this entire manual before unpacking, setting up or operating
this equipment. Pay attention to all danger and caution statements.
Failure to do so could result in serious injury to the operator or damage
to the equipment.
Make sure that the protection provided by this equipment is not impaired.
Do not use or install this equipment in any manner other than that
specified in this manual.
Use of hazard information
DANGER
Indicates a potentially or imminently hazardous situation which, if not avoided, will
result in death or serious injury.
W A R N I N G
Indicates a potentially or imminently hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation that may result in minor or moderate
injury.
NOTICE
Indicates a situation which, if not avoided, may cause damage to the instrument.
Information that requires special emphasis.
Precautionary labels
Read all labels and tags attached to the instrument. Personal injury or
damage to the instrument could occur if not observed. A symbol on the
instrument is referenced in the manual with a precautionary statement.
This symbol, if noted on the instrument, references the instruction
manual for operation and/or safety information.
Electrical equipment marked with this symbol may not be disposed of
in European public disposal systems after 12 August of 2005. In
conformity with European local and national regulations (EU Directive
2002/96/EC), European electrical equipment users must now return
old or end-of-life equipment to the Producer for disposal at no charge
to the user.
Note: For return for recycling, please contact the equipment producer or supplier
for instructions on how to return end-of-life equipment, producer-supplied
electrical accessories, and all auxiliary items for proper disposal.
This symbol indicates that a risk of electrical shock and/or
electrocution exists.
This symbol indicates the need for protective eye wear.
This symbol indicates that the marked item requires a protective earth
connection. If the instrument is not supplied with a ground plug on a
cord, make the protective earth connection to the protective
conductor terminal.
English 5

This symbol indicates that the marked item is the functional ground
connection for cable shield wires. Do not connect the ground wire of a
power cord or conduit to this item.
This symbol, when noted on the product, identifies the location of a
fuse or current limiting device.
Certification
Canadian Radio Interference-Causing Equipment Regulation,
IECS-003, Class A:
Supporting test records reside with the manufacturer.
This Class A digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil numérique de classe A répond à toutes les exigences de la
réglementation canadienne sur les équipements provoquant des
interférences.
FCC Part 15, Class "A" Limits
Supporting test records reside with the manufacturer. The device
complies with Part 15 of the FCC Rules. Operation is subject to the
following conditions:
1. The equipment may not cause harmful interference.
2. The equipment must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications to this equipment not expressly approved by
the party responsible for compliance could void the user's authority to
operate the equipment. This equipment has been tested and found to
comply with the limits for a Class A digital device, pursuant to Part 15 of
the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference
to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference, in which case the user will be
required to correct the interference at their expense. The following
techniques can be used to reduce interference problems:
1. Disconnect the equipment from its power source to verify that it is or
is not the source of the interference.
2. If the equipment is connected to the same outlet as the device
experiencing interference, connect the equipment to a different
outlet.
3. Move the equipment away from the device receiving the interference.
4. Reposition the receiving antenna for the device receiving the
interference.
5. Try combinations of the above.
Product overview
DANGER
Chemical or biological hazards. If this instrument is used to monitor a
treatment process and/or chemical feed system for which there are
regulatory limits and monitoring requirements related to public health,
public safety, food or beverage manufacture or processing, it is the
responsibility of the user of this instrument to know and abide by any
applicable regulation and to have sufficient and appropriate
mechanisms in place for compliance with applicable regulations in the
event of malfunction of the instrument.
This analyzer continuously measures the hardness or the concentration
of a specific substance (alkalinity, ammonia or ammonia and
monochloramine) in drinking water, power water and industrial water.
Refer to Figure 1–Figure 3 for an overview of the analyzer.
6 English

Figure 1 Instrument overview – front
1 Door14 Drain block (sample drain)
2 Bottle enclosure for reagents25 Pressure gauge for drain block
3 Bottle enclosure for standards and
cleaning solution
6 Keypad and display
1Keep the door and door latch closed during operation so that the temperature
control system operates correctly.
2Reagents are light sensitive. Keep the bottle enclosure closed when bottles
are not being replaced.
Figure 2 Instrument overview – back
1 Air purge fitting 4 Case drain
2 Tubing strain relief holes 5 Sample conditioning block (sample
inlet)
3 Electrical access holes for external
cabling
English 7

Figure 3 Instrument overview – interior
1 Mixing module 4 Colorimeter module
2 Valve module 5 Pump (autoburette) module
3 Power switch
Product components
Make sure that all components have been received. Refer to
Figure 4–Figure 7. If any items are missing or damaged, contact the
manufacturer or a sales representative immediately.
Figure 4 Instrument components
1 APA 6000 analyzer 5 Reagent bottles1, 1 L
2 Tool kit (Figure 5)6 Standard solution bottles, 1 L (2x)
3 Installation kit (Figure 6)7 Cleaning solution bottle, 1 L
4 Maintenance kit (Figure 7)8 Powder funnel2
1The number of reagent bottles varies by analyzer model.
2Supplied only with the high range hardness analyzer
8 English

Figure 5 Tool kit
1 Tubing cutter, for Tefzel 0.030 ID x
0.062 OD tubing
7 Hex nut, 10-32, for 0.062-in. OD
tubing (4x)
2 Flangeless nut extender 8 Ferrule with locking ring, for 0.062-
in. OD tubing (10x)
3 Wrench, ¼-in., for the rotary valve 9 Flangeless nut, ¼-28, for 0.062-in.
OD tubing (10x)
4 Wrench, allen, 7/64-in. 10 Flangeless nut, plug, ¼-28
5 Alignment tool for the pump module 11 Fitting, union, Tefzel, ¼-in. (4x)
6 Ferrule, for 0.062-in. OD tubing (4x) 12 Tubing, Tefzel, 0.030 ID x
0.062 OD, 4.6 m (15 ft)
Figure 6 Installation kit
1 Grab sample kit 3 Ceramic filters, 0.5 µm (4x)
2 Tubing, polyethylene, 0.25-in. OD
x .040-in. ID, 6m (20 ft)
Figure 7 Maintenance kit
1 Valve rotors (4x) 3 Pump O-rings, fluorocarbon,
0.676 ID x 0.070 wide (4x)
2 Pump piston seals, flanged,
0.722 OD x 0.104 long (8x)
4 High temperature, non-flammable
grease
English 9

Installation
W A R N I N G
Multiple hazards. Only qualified personnel must conduct the tasks
described in this section of the document.
Installation guidelines
• Install the analyzer as near to the sampling point as possible.
• Make sure to leave sufficient space above the analyzer to install
analyzer bottles in the bottle enclosures. Refer to Figure 8.
• Make sure to leave sufficient space in front of the analyzer to open the
analyzer door. Refer to Figure 8.
• Install the analyzer indoors, in a non-hazardous environment.
• Do not install the analyzer in direct sunlight or near a heat source.
• Make sure that the ambient conditions are within operating
specifications. Refer to Specifications on page 3.
Figure 8 Analyzer dimensions
10 English
Table of contents
Languages:
Other Hach Measuring Instrument manuals

Hach
Hach Polymetron 9523sc pH Quick manual

Hach
Hach 59530-16 User manual

Hach
Hach TL2350 Quick manual

Hach
Hach 9523sc User manual

Hach
Hach ORBISPHERE 410 User manual

Hach
Hach TU5300 sc Quick manual

Hach
Hach sensION3 Reference guide

Hach
Hach SP-510 User manual

Hach
Hach Sigma 950 User manual

Hach
Hach HQd Quick manual

Hach
Hach ORBISPHERE 3654 Quick manual

Hach
Hach 2100N User manual