FT-111, User Manual Rev. 2.0.0, June 2022 Page 3of 137
7.4 EPL Format..........................................................................................................................................................................42
7.5 BSI Data Structure for Dialog with PC........................................................................................................................42
7.6 Fieldbus Interface..............................................................................................................................................................42
8Programming and Calibration...............................................................................43
8.1 Alphanumeric Entry for Headers and Footers.........................................................................................................43
8.2 Entering to the Programming and Calibration........................................................................................................44
8.3 Quick Access Parameter Blocks used frequently....................................................................................................44
8.4 Exit from Programming..................................................................................................................................................44
8.5 Programming and Parameters....................................................................................................................................45
[1-- INTERFACE] Interface Block ...........................................................................................................................46
[2-- CONFIGURATIO] Configuration Block..............................................................................................................56
[3-- APPLICATION] Application Block..................................................................................................................58
[5-- SCALE] Scale Block............................................................................................................................................61
[6-- CALB / ADJUST] Calibration and Adjustment Block...................................................................................64
[8-- METROLOGY] Metrology Block ...................................................................................................................65
[9-- DIAGNOSTIC] Diagnostic Block.....................................................................................................................66
8.6 Calibration ...........................................................................................................................................................................68
8.6.1 Linearity Correction..........................................................................................................................................................68
8.6.2 Zero and Span Adjustments..........................................................................................................................................69
8.6.3 eCal Electronic Calibration.............................................................................................................................................70
8.6.4 Gravity adjustment............................................................................................................................................................71
8.6.5 Calibration coefficients.....................................................................................................................................................71
9Digital Load Cells (DLC).............................................................................................72
9.1 Addressing of Digital Load cells.................................................................................................................................... 72
10 Sealing of Approved Scale.......................................................................................75
11 Optional Boards...........................................................................................................76
11.1 Digital Inputs and Outputs.............................................................................................................................................76
11.2 Alibi Memory .......................................................................................................................................................................77
11.2.1 Installation of Alibi SD card.............................................................................................................................................77
11.2.2 Activating Alibi Memory..................................................................................................................................................78
11.2.3 How is the Data Recorded into the Alibi Memory?................................................................................................78
11.2.4 Recall Data from Alibi Memory....................................................................................................................................78
11.3 Installation of SD Card.....................................................................................................................................................80
11.4 BSI Protocol to Interface with PC and PLC.................................................................................................................81
11.4.1 BSI-Base Commands.......................................................................................................................................................82
11.5 Continuous Data Formats..............................................................................................................................................88
11.6 Analogue Output................................................................................................................................................................91
11.6.1 Analogue Output Connection.........................................................................................................................................91
11.7 Modbus RTU .......................................................................................................................................................................93
11.7.1 Modbus RTU Data Structure .........................................................................................................................................93
11.8 Ethernet TCP/IP.................................................................................................................................................................99
11.8.1 Ethernet Parameters .......................................................................................................................................................99
11.8.2 Modbus TCP Data Structure........................................................................................................................................100
11.9 Profibus DP ........................................................................................................................................................................101
11.9.1 Electrical Connection.......................................................................................................................................................101
11.9.2 Data Format.....................................................................................................................................................................102
11.9.3 GSD Configuration..........................................................................................................................................................102
11.9.4 Profibus DP Data Structure .........................................................................................................................................102
11.10 Profinet...............................................................................................................................................................................103
11.10.1Electrical Connection......................................................................................................................................................104
11.10.2 Data Format...............................................................................................................................................................104
11.10.3 Profinet Parameters ................................................................................................................................................105
11.10.4 GSDML Configuration..............................................................................................................................................105