8
SELECT THE METER SIZE – At the METER prompt,
press the ENTER button once. The current meter size number
will begin to flash. Using the arrow keys, scroll through the
size choices until you find the bore size of your meter. Press
ENTER once to save the meter size choice.
SELECT THE DISPLAY FUNCTION – The monitor can
display RATE or TOTAL or alternate between BOTH rate
and total. At the DISPLAY prompt, press the ENTER key
once. The monitor now shows the display mode currently in
effect. If the current selection is correct, press the ENTER key
to advance to the next parameter. To change to an alternate
display mode, use the arrow keys to scroll to the desired dis-
play mode and press ENTER to save the choice.
SELECT THE RATE UNITS OF MEASURE – The moni-
tor allows the choice of many common rate units. (See the
specifications for a complete listing of the unit choices.) At
the RATE UNT prompt, press the ENTER key once. The
monitor now shows the rate units of measure the display is
currently set for. If the current selection is correct, press the
ENTER key to advance to the next parameter. To change to
an alternate unit, use the arrow keys to scroll to the desired
rate unit and press ENTER to save the choice.
SELECT THE RATE [TIME] INTERVAL – The term
Rate implies that something is occurring over a period of
time. Most people are familiar with the rate of speed of a car
reported in miles per hour (MPH). The same concept holds
true for a flow meter. The time choices are SEC (seconds),
MIN (minutes), HOUR (hours), and DAY (days). At the
RATE INT prompt, press the ENTER key once. The monitor
now shows the time interval the display is currently set for. If
Note: The meter connection size and the bore size are different.
For example, many of the 1” NPT turbines have bore sizes that
range from 3/8” up to 1”. Be sure to use the correct bore size or
the meter could report incorrect flows and totals.