Viso Systems LabSpion User manual

LabSpion
User Manual
Last edited November 26, 2018

2
Content
Safety Information...........................................................................................................................4
Preventing electric shocks...........................................................................................................4
Introduction.....................................................................................................................................5
Dimensions.....................................................................................................................................6
Goniometer .................................................................................................................................6
Packaging and weight.....................................................................................................................7
LabSpion items...............................................................................................................................7
Shipping Packages......................................................................................................................9
Room considerations....................................................................................................................10
Sensor distance.........................................................................................................................10
Goniometer Dark zone..............................................................................................................11
Minimum room dimensions........................................................................................................12
Measuring through a door opening............................................................................................12
Narrow room considerations......................................................................................................14
Light baffle.............................................................................................................................14
Creating a Light Baffle ...........................................................................................................15
Installation.....................................................................................................................................16
Software installation..................................................................................................................16
Connect power..........................................................................................................................17
Connect USB ............................................................................................................................18
Connecting the LabSensor........................................................................................................19
Connecting the C-plane goniometer..........................................................................................19
Connecting lamp power.............................................................................................................20
Connecting diagram ..................................................................................................................21
Alignment of the sensor ................................................................................................................22
Height alignment .......................................................................................................................22
Set distance of the sensor.........................................................................................................23
Mounting and Alignment of the lamp.............................................................................................24
Use of the Laser Level Tool.......................................................................................................24
Adjust lamp to laser...................................................................................................................25
Center of luminares...................................................................................................................26
Mounting of fixtures with a static base.......................................................................................28
Adjustment of the lamp holder arm............................................................................................29
Mount lamps with counter weight ..............................................................................................30

3
Making measurements..................................................................................................................31
Alignment of the sensor.............................................................................................................31
Making a measurement.............................................................................................................31
Specifications................................................................................................................................32

4
Safety Information
Warning! This product is not for household use.
Read this manual before installing and operating the LabSpion, follow the safety warnings listed
below, and study all the cautions in the manual.
Preventing electric shocks
Make sure the power supply is always grounded.
Use a source of AC power that complies with the local building and electrical codes,
that has both overload and ground-fault protection.
If the controller or the power supply are in any way damaged, defective, wet, or show signs of
overheating, disconnect the power supply from the AC power and contact Viso Service for
assistance.
Do not install or use the device outdoors. Do not spray with or immerse in water or any other liquid.
Do not remove any covers or attempt to repair the controller or the power supply. Refer any
service to Viso.
Disposing of this product
Viso products are supplied in compliance with
Directive 2002/96/EC of the European Parliament
and of the Council of the European Union on
WEEE (Waste Electrical and Electronic
Equipment), as amended by Directive
2003/108/EC, where applicable.
Help preserve the environment! Ensure that this
product is recycled at the end of its lifetime. Your supplier
can give details of local arrangements for the disposal of
Viso products.

5
Introduction
About this document
These guidelines describe the installation process of the LabSpion controller followed by the typical
measurements of various light sources.
About the LabSpion
The LabSpion is a revolutionary new far field goniometer system with a spectrometer sensor that
makes it possible to measure all photometric measurements quickly and efficiently. The Light
Inspector software enables to quickly measure, save and export the newly obtained data.
© 2007 Viso Systems ApS, Denmark
All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing
from Viso Systems ApS, Denmark.
Information subject to change without notice. Viso Systems ApS and all affiliated companies disclaim liability for any
injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of,
inability to use or reliance on the information contained in this manual.

6
Dimensions
Goniometer
The minimum distance between the LabSpion goniometer and the back wall is 1 meter. The
minimum distance between the sensor and the end wall is 0.5 meters.
1646
511 118 1017
1248
111
450
182
1534
124
906
1332
450
823
281
598
A A
B B
C C
D D
E E
F F
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
DRAWN
CHK'D
APPV'D
MFG
Q.A
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
SURFACE FINISH:
TOLERANCES:
LINEAR:
ANGULAR:
FINISH: DEBURR AND
BREAK SHARP
EDGES
NAME
SIGNATURE
DATE
MATERIAL:
DO NOT SCALE DRAWING
REVISION
TITLE:
DWG NO.
SCALE:1:50 SHEET 1 OF 1
A3
WEIGHT:
LabSpion Assem Front dimensions

7
Packaging and weight
LabSpion item list
•Base
•Tower
•Stand
•C-plane head
•Lamp Bracket
•E27 Lamp holder
•Tripod
•Sensor
•Cali T50
•Bosch Cross Line Laser
Documents
•Assembly Manual
•Sensor Calibration Certificate
•Cali T50 certificate
Base: 27 kg Tower + C-Plane Head: 25 kg
Tripod + Lamp Bracket + E27 Holder
Stand: 24kg
Sensor + Cali T50: 6kg

8
Assembly Box
•2 m IEC power cord
•5 m USB cable
•3 m RJ45 for connection between LabSpion Base and C-Plane Gonio Head
•25m RJ45 cat 5 for connection between LabSpion Base and LabSensor
•Light Inspector USB stick (Windows)
•Bulb adaptor: E27, E14, G10, B22.
•Laser Distance Plate
•1 x Steel Pin 200mm
•2 x Steel Pin 45 degree handle
•6 x Plastic end caps for pins
•2 x Small Lamp Brackets + M10 Handles + 20mm Plastic Spacer
•2 x M8 Handle + Thumb Screw for Base attach
•8 x M6x35mm Screws for Lamp Bracket mounting
•8 x 20mm plastic spacers for Lamp Bracket Mount
•2 x M6 Thumb Screws for Laser Distance Plate

9
Shipping Packages
Shipping packages Shipping dimensions CBM Weight
1. Sensor + Cali 56 x 56,5 x 35 cm 0,111m36 Kg
2. Base 51 x 51 x 22 cm 0,057 m327 Kg
3. Bracket + Tripod + Assembly Parts 165,5 x 29,5 x 32 cm 0,156 m38 Kg
4. Tower + C-plane Gonio 45,5 x 35 x 118 cm 0,188 m325 Kg
5. Stand 61 x 60,5 x 82 cm 0,302 m324 Kg
Total: 0,814 m390 kg
Total shipping weight: 90 kg.
Total shipping CBM: 0,814m3
The shipment is done in a total of 5 packages.
Dimensions on a single pallet: L:168 W:90 H:120, Total CBM:1,814

10
Room considerations
Sensor distance
The measurement method used in the LabSpion system is called far field, which means the distance
between the measuring light source and the sensor should be at least 8x the diameter of the lamp
as shown below.
Sensor distance = 8 x Lamp diameter
Lamp diameter Minimum sensor distance
0,25 m 2 m
0,50 m 4 m
1,00 m 8 m
1,50 m 12 m
Note !! The “Lamp diameter” is only the
illuminating part of the lamp.
Physical Diameter
Lamp Diameter
Other manuals for LabSpion
3
Table of contents
Other Viso Systems Measuring Instrument manuals

Viso Systems
Viso Systems LightSpion LIGSP001 User manual

Viso Systems
Viso Systems LabSpion User manual

Viso Systems
Viso Systems BaseSpion User manual

Viso Systems
Viso Systems LabFlicker User manual

Viso Systems
Viso Systems LightSpion User manual

Viso Systems
Viso Systems LabSpion User manual

Viso Systems
Viso Systems VISO SYSTEMS Labarazzi User manual