TST TM-510 User manual

Wireless Tire Pressure and Temperature
Monitoring System Instrucon Manual
Model #: TM-510
510 Cap Sensors
Thank you for purchasing the TST Tire Pressure Monitoring
System. With minimal care, your new TPMS will
provide reliable service for many years. Please read and
understand the informaon contained within this manual.
Keep this manual for future reference.
Telephone: 770.889.9102
Website: www.tsruck.com
TST-Doc-510 Manual-(A)
Truck System Technologies - 4250 Keith Bridge Road, Suite 200, Cumming, GA 30041
1

INDEX
Page 1 - Sensor Features
Page 1 - Display Features
Page 2 - System Components in Kit
Page 3 - Display Controls/Display Components and Icons
Pages 4 - 6 - Programming Sensor Codes Into the Display
- Manual Coding (Opon #1)
- Automac Code Learning (Opon #2)
Page 7 - Sensor Installaon
Page 8 - Display Installaon
Pages 8 - 11 - Parameter Sengs (Pressure & Temperature)
Page 12 - Monitor Alerts
Page 13 - Other Funcons
Page 14 - Troubleshoong Tips/Sensor Baeries
Pages 16 - 18 - Common Quesons
Page 19 - Repeater
Page 19 - Sensor Specicaons
Page 20 - Display Specicaons
Page 21 - Notes
TST-Doc-510 Manual-(A)
Truck System Technologies - 4250 Keith Bridge Road, Suite 200, Cumming, GA 30041
2

SENSOR FEATURES
1. Sensors easily install on the valve stem.
2. Sensors are water resistant.
3. Pressure and temperature data is read every two (2)
minutes.
4. Removal of a sensor (0 lbs. pressure) will shut o the sensor
baery.
5. Tire leaks and high-temperatures are detected quickly.
6. Each sensor has a unique, four (4) digit code for programming.
7. Sensor baeries last approximately 3-4 years.
8. Sensors feature an an-the cap.
DISPLAY FEATURES
1) Easy to read display.
2) Mount included.
3) Integrated lithium-ion baery that is rechargeable with
provided cord.
4) Wake-up acvaon of display when in moon.
5) Automac display illuminaon in dark condions.
6) Programable high and low-pressure alarm thresholds.
7) Programmable high-temperature alarm.
8) Visual and audible warning alarms when temperature or
pressure exceeds thresholds.
9) Mulple pressure units: PSI, BAR, Kpa and Kgf/cm2.
TST-Doc-510 Manual-(A)
Truck System Technologies - 4250 Keith Bridge Road, Suite 200, Cumming, GA 30041
3

10) Selectable temperature unit: °C or °F
11) Program up to 22 res.
12) Tire pressure and temperature is displayed simultaneously
for quick viewing of each re.
13) The trailer display can be electronically removed from the
screen when not towing.
14) Push buon programming.
15) A fully charged display will connuously operate 5-7 days on
baery power.
16) Tire temperature and pressure sengs are congured “per
axle.”
SYSTEM COMPONENTS IN KIT
Display
Power Adapter
Hard Wire Kit
Display Holders Long Antenna
Sensors Installation Tools
TST-Doc-510 Manual-(A)
Truck System Technologies - 4250 Keith Bridge Road, Suite 200, Cumming, GA 30041
4

DISPLAY CONTROLS
•There are four (4) programming buons located across
the lower front face of the display. They are: “MODE,”
(+), (-) and “SET.”
•The power switch is the (-) buon on the front of the
display. Hold it for approximately six (6) seconds to turn
on the display. To turn o the display, press and hold the
same (-) buon for about six (6) seconds.
NOTE: The power switch will not turn o the monitor when
constant power is applied to the unit either by the power adapter
or the hardwire kit.
Pressure Unit: BAR, PSI, Kpa or Kgf/cm2, user-selectable.
Temperature unit: C° or F°, user-selectable.
DISPLAY COMPONENTS AND ICONS
Tire Indicator
Low Sensor Baery
Fast Leakage
High Pressure
Low Pressure
High Temperature
Display Baery
TST-Doc-510 Manual-(A)
Truck System Technologies - 4250 Keith Bridge Road, Suite 200, Cumming, GA 30041
5

PROGRAMMING SENSOR CODES INTO THE DISPLAY
Note: It is recommended to label each sensor rst with the
provided numbering code sckers, similar to the following
paern, before you code the sensors. This allows you to know
which sensor is programmed to which re posion. You can also
write in your sensor number paern.
SENSOR MANUAL CODING (Opon #1)
Note: Code all the sensors to the display BEFORE screwing them
onto the re valve stem unless otherwise noted.
Also…A code of all F’s (FFFF) means the re icon will NOT show up
on the display screen. If any of the digits are not “F,” the system
will interpret this as a code and the re icon WILL show on the
screen. To delete any re posion, the code must be set to “FFFF.”
•Turn the display on by holding the (-) buon down unl
it beeps. You will now be on the Main Screen.
Or use your own paern:
TST-Doc-510 Manual-(A)
Truck System Technologies - 4250 Keith Bridge Road, Suite 200, Cumming, GA 30041
6

•Press and hold the “SET” buon unl it beeps and then
release it (approx. 5-7 seconds). You are now in the code
programming mode.
•A re icon will ash and all 22 res will be displayed.
“FFFF” should be displayed.
•Navigate to the re you want to code by quickly pressing
the “SET” buon unl you arrive at the re posion on
the screen.
•Enter the rst digit of the four-digit code from the sensor
using the (+) or (-) buons.
•Move to the next digit by quickly pushing the “MODE”
buon. Enter the second digit of the code with the (+) or
(-) buons.
•Press “MODE” to go to the third digit. Enter it.
•Press “MODE” and put in the fourth and nal digit for
that re posion. When done you can:
•Quickly press “SET” to move on to another re posion
to enter the next four-digit code.
OR
•Press and hold the “SET” buon to save the code you
entered.
Note: If the right front re is blinking and does not show all “F’s”
you can delete the factory test sensor code as follows:
•Press the “SET” buon unl it beeps (approx. 4-6
seconds). The display should now show a code other
than “FFFF.” This display indicates the re posion is
coded and will show on the Main Screen.
TST-Doc-510 Manual-(A)
Truck System Technologies - 4250 Keith Bridge Road, Suite 200, Cumming, GA 30041
7

•To remove the re icon from the screen, the four-digit
code has to display all F’s. With the rst digit ashing, set
it to “F” using the (+) or (-) buons.
•Press “MODE” to move to the next digit. Set that to “F.”
•Connue to set all the digits to “F.” When done and with
“FFFF” showing on the screen, press and hold the set
buon unl it beeps. This will save the code you entered
and exit the programming mode.
Note: When in the coding mode, the display will me-out within
approximately one (1) minute if no buons are pushed. At that
point, you will have to again hold the “SET” buon down and
start the coding process again.
AUTOMATIC CODE LEARNING (Opon #2)
•Be sure your display is ON and it is showing the main
screen.
•Be sure your sensors are numbered. Screw the sensors
partly onto each valve stem in the order you numbered
them. Do NOT screw them down far enough to hear air
hissing out.
•Hold the “SET” buon down unl you hear a second
beep and then release.
•Navigate to the re icon you want to code that sensor to
on the display.
•Stand by that re and screw the sensor all the way down
to seat it.
•The sensor will immediately transmit its four-digit code
to the display and it will be displayed.
•Physically move to the next re posion you want to
code.
TST-Doc-510 Manual-(A)
Truck System Technologies - 4250 Keith Bridge Road, Suite 200, Cumming, GA 30041
8

•Using the (+) or (-) buon, navigate to the re on the
monitor you are standing at.
•Again, nish screwing that sensor down to seat it. That
code now will appear on the monitor.
•Connue this procedure unl you have coded all the
sensor posions.
•Finally, press the “SET” buon unl it beeps to save all
the sensor codes in the monitor.
SENSOR INSTALLATION
•Be sure to write down your sensor code in this manual in
the correct re posion for future reference.
•Using one of the tools included with your kit, slip the
sensor into the tool.
•Screw the correct sensor onto the valve stem for that re
posion. Tighten the sensor unl the air stops leaking
and the sensor booms-out on the valve stem. Then give
it a slight twist to seat it. Do Not Overghten!
•We suggest adding dielectric grease to the sensor threads
to prevent the threads from seizing to the valve stem
over me.
TST-Doc-510 Manual-(A)
Truck System Technologies - 4250 Keith Bridge Road, Suite 200, Cumming, GA 30041
9

DISPLAY INSTALLATION
•There are two ways to mount the display to your dash.
•The vent clip can be aached to the display and then
clipped inside one of the vehicle A/C vents.
•Oponally, the provided velcro pads can be used to
secure the display to the top of the dash.
•Plug the power cord into the vehicle’s power port and
then into the side of the monitor to charge the internal
lithium baery. Charge the display for four (4) hours the
rst me.
•An oponal hardwire cord is provided if you choose to
wire the display into your vehicle’s ignion switch. In this
case, the monitor will automacally come on when the
ignion is on.
PARAMETER SETTINGS (Seng the sensor alarms)
NOTE: The factory default sengs are:
Pressure Unit: PSI Temperature units: °C
High Pressure: 175 lbs. High Temperature: 70°C (158° F)
Low Pressure: 100 Lbs.
TST-Doc-510 Manual-(A)