Topcon CL-300 User manual

USER MANUAL
COMPUTERIZED LENSMETER
CL-300
FRONT COVER

1
INTRODUCTION
Thank you for purchasing the TOPCON Computerized Lensmeter CL-300.
FEATURES
This instrument has the following features:
• High accuracy measurements with ease of operation
• The LCD touch panel will facilitate operation
PURPOSE OF THIS MANUAL
This Instruction Manual covers an overview of the TOPCON Computerized Lensmeter CL-
300, basic operations, troubleshooting, maintenance and cleaning.
To ensure the efficient, safe use, read through “DISPLAYS AND SYMBOLS FOR SAFE USE”
and “GENERAL SAFETY INFORMATION” and use the instrument correctly.
Keep this Instruction Manual within reach for future reference.

2
1. No part of this manual may be copied or reprinted, in whole or in part, without
prior written permission.
2. The contents of this manual are subject to change without prior notice and with-
out legal obligation.
3. The contents of this manual are correct to the best of our knowledge. Please
inform us of any ambiguous or erroneous descriptions, missing information, etc.
2012 TOPCON CORPORATION
ALL RIGHTS RESERVED

3
CONTENT
INTRODUCTION ........................................................................................................1
GENERAL SAFETY INFORMATION..........................................................................5
HOW TO READ THIS MANUAL.................................................................................6
GENERAL MAINTENANCE INFORMATION .............................................................6
USER MAINTENANCE...............................................................................................6
DISCLAIMERS ...........................................................................................................6
DISPLAYS AND SYMBOLS FOR SAFE USE............................................................7
SYMBOLS ..................................................................................................................7
WARNING INDICATIONS AND POSITIONS .............................................................8
COMPONENTS
ACCESSORIES..........................................................................................................9
COMPONENT NAMES.............................................................................................10
COMPARTMENT SPACE.........................................................................................11
OPERATION METHOD OF CONTROL ...................................................................11
CONTROL PANEL COMPONENTS.........................................................................12
MEASUREMENT SCREEN......................................................................................14
SETUP SCREEN......................................................................................................17
PREPARATION
INSTALLATION ........................................................................................................18
SETTING THE PAPER.............................................................................................19
AUTO POWER SAVE FUNCTION ...........................................................................20
USING THE INSTRUMENT
CHECKING BEFORE MEASURING ........................................................................21
SETTING OF A LENS ..............................................................................................21
MEASURING A SINGLE FOCAL LENS ...................................................................22
MEASURING A PROGRESSIVE LENS ...................................................................24
MEASURING BI-FOCAL AND TRI-FOCAL LENSES...............................................28
MEASURING BI-FOCAL AND TRI-FOCAL LENSES (MEASURING THE DIOPTER
POWER OF LENSES WITH THE CONCAVE SIDE UP) .........................................29
MEASURING A CONTACT LENS............................................................................30
A:STEP MODE .........................................................................................................32
UV TRANSMISSION MEASUREMENT....................................................................32
AXIS MARKING
(CARTRIDGE SPECIFICATION/STEEL NEEDLE SPECIFICATION) .....................34
PRINTING ADDITIONAL TEXTBOX (WITH PRINTER SPECIFICATION) ..............37
SETTING A SEQUENCE NO. ..................................................................................38
LENS PROTECTION PAD .......................................................................................38
MEASURING PD (PD FITTING) (WITH PD SPECIFICATION)................................39
HOW TO OUTPUT DATA.........................................................................................41

4
SETTING FUNCTIONS ON SETUP SCREEN
OPERATING THE SETUP SCREEN........................................................................42
LIST OF SETUP ITEMS ...........................................................................................45
MAINTENANCE ........................................................................................................49
BEFORE REQUESTING SERVICE
CAUTION MESSAGES ............................................................................................51
CHECK ITEMS .........................................................................................................51
SPECIFICATIONS
SPECIFICATIONS....................................................................................................52
WITH PRINTER SPECIFICATION ...........................................................................52
OPTIONAL ACCESSORIES.....................................................................................52
GENERAL INFORMATION ON USAGE AND MAINTENANCE
ENVIRONMENTAL CONDITIONS FOR USE ..........................................................53
STORAGE, USAGE PERIOD AND OTHERS ..........................................................53
SAFETY DESIGNATIONS PER IEC 60601-1 STANDARD .....................................53
MAINTENANCE AND CHECKS ...............................................................................54
DISPOSAL................................................................................................................54
INTENDED USER PROFILE ....................................................................................54
ELECTROMAGNETIC COMPATIBILITY..................................................................55
SHAPE OF PLUG.....................................................................................................59
USING THE INSTRUMENT AS A SYSTEM
ON - LINE SYSTEM .................................................................................................60

5
GENERAL SAFETY INFORMATION
Preventing Electric Shocks and Fire
To avoid fire and electric shocks, do not place a cup or vessel containing water/fluid on the
instrument.
To avoid electric shocks, do not insert objects through vent holes or gaps or force them
inside the machine body.
To avoid electric shocks, do not attempt disassembling, rebuilding or repairing. For repairs,
call your dealer.
To avoid fire/electric shocks, do not install the instrument in a place where it may get wet.
If there is a malfunction or if the instrument produces smoke, immediately turn OFF the
POWER switch and unplug the power cable. To a avoid a possible fire due to malfunction,
call your dealer and ask for repairs.
Ensuring the Safety of Patients and Operators
To avoid injury by falling, do not install the instrument on a slope or in an unstable place.
Preventing Electric Shocks and Fire
Do not open the cover. For repairs, contact your Topcon dealer.
[The instrument may injure someone by electric shock.]
Electromagnetic Compatibility (EMC)
This instrument has been tested (with 100-240V) and found to comply with IEC60601-1-2:
2001. This instrument radiates radio frequency energy within standard and may affect other
devices in vicinity. If you have found out by turning on/off the instrument that it affects other
devices, it is recommended to change the direction, keep a proper distance against other
devices or change the outlet. If you have a question, consult with the selling agent.
WARNINGS
CAUTIONS

6
HOW TO READ THIS MANUAL
• Read the instructions on pages 5 to 8 before using the machine.
• If you would like an overview of the system, begin by reading "USING THE INSTRU-
MENT"(page 21).
• For setting various functions, see "SETTING FUNCTIONS ON SETUP SCREEN" on page
42.
GENERAL MAINTENANCE INFORMATION
USER MAINTENANCE
To maintain the safety and performance of the equipment, never attempt to repair or perform
maintenance. These tasks should be performed by an authorized service representative.
Maintenance tasks that can be performed by the user are as follows; for details, follow the
manual’s instructions.
CLEANING COVER GLASSES
For details, see page 50 of this manual.
DISCLAIMERS
• TOPCON shall not take any responsibility for damages due to fire, groundquake, actions by
third person, or the negligence and misuse by the user and used under unusual conditions.
• TOPCON shall not take any responsibility for damage derived from the inability to use this
equipment, such as a loss of business profit and suspension of business.
• TOPCON shall not take any responsibility for damage caused by operations other than
those described in this Instruction Manual.

7
DISPLAYS AND SYMBOLS FOR SAFE USE
In order to encourage the safe use of this product, warnings labels are placed on the product and
written in the instruction manual.
We suggest that everyone understands the meaning of the following displays and icons before
reading the “GENERAL SAFETY INFORMATION” and text.
DISPLAYS
SYMBOLS
Display Meaning
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.
Useful functions to know and attentions to prevent
troubles are noted.
Symbol IEC/ISO Publication Description Description (French)
IEC 60417-5032 Alternating Current Courant alternatif
IEC 60417-5008 Off (power: disconnection
from the main power supply)
Éteint (courant: coupure
avec le secteur)
IEC 60417-5007 On (power: connection to
the main power supply)
Allumé (courant: raccor-
dement sur le secteur)
ISO 7010-W001 General warning sign Symbole d'avertissement
général
WARNINGS
CAUTIONS
NOTES

8
WARNING INDICATIONS AND POSITIONS
To insure safety, warning labels are provided.
Use the equipment correctly by following the warning instructions. If any of the following labels
are missing, please contact us at the address stated on the back cover.
No. Label Meaning
1
WARNING
To avoid injury caused by electric shock, do not open the cover.
Ask your dealer for service.
WARNING
To avoid injury, do not touch the AC adapter jack while using the
AC adapter.
1

9
COMPONENTS
COMPONENTS
ACCESSORIES
The following are standard accessories. Make sure that all these items are included (quantity).
)1(dapnoitcetorpsneL)1(elbacrewoP
)1(htolcnociliS) Model name: BPM040S09F021(retpadaCA
)1(revoctsuD)1(troppussneltcatnoC
Printer paper (2)
(with printer specification)
User manual (1)
Instruction manual (1)
Guarantee sheet (1)
INSTRUCTION MANUAL
COMPUTERIZED LENSMETER
CL-300
Other manuals for CL-300
1
Table of contents
Other Topcon Measuring Instrument manuals

Topcon
Topcon CT-800 User manual

Topcon
Topcon KR-1 User manual

Topcon
Topcon RL-VH3C User manual

Topcon
Topcon BM-7A User manual

Topcon
Topcon RL-VH3A User manual

Topcon
Topcon RC-5 User manual

Topcon
Topcon GPT-3000 Series User manual

Topcon
Topcon HiPer Plus User manual

Topcon
Topcon RL-VH4DR/G2 User manual

Topcon
Topcon GTS-710 Series User manual

Topcon
Topcon OS-101 User manual

Topcon
Topcon FC-2600 User manual

Topcon
Topcon PS Series User manual

Topcon
Topcon OS Series User manual

Topcon
Topcon i-33 User manual

Topcon
Topcon ES-101 User manual

Topcon
Topcon GM-100 Series User manual

Topcon
Topcon TP-L5GV User manual

Topcon
Topcon 2LS Taurus User manual

Topcon
Topcon BM-9A User manual