TLV EF200R-C Manual

172-65760M-01(EF200R-CVortexflowmeter)7June2022
EF200R-C
Vortexflowmeter
Copyright©2022byTLVCO.,LTD.
Allrightsreserved

EF200R-C
2
Tableofcontents
Aboutthisdocument
Symbols
Functionandsystemdesign
Measuringprinciple
Measuringsystem
Input
Measuredvariable
Measuringrange
Operableflowrange
Output
Outputsignal
Signalonalarm
Load
Lowflowcutoff
Galvanicisolation
Protocol-specificdata
Powersupply
Terminalassignment
Supplyvoltage
Powerconsumption
Currentconsumption
Powersupplyfailure
Electricalconnection
Potentialequalization
Terminals
Cableentries
Cablespecification
Overvoltageprotection
Performancecharacteristics
Referenceoperatingconditions
Maximummeasurederror
Repeatability
Responsetime
Influenceofambienttemperature
Installation
Mountinglocation
Orientation
Inletandoutletruns
Lengthofconnectingcable
Mountingthetransmitterhousing
Environment
Ambienttemperaturerange
Storagetemperature
Climateclass
Degreeofprotection
Vibration-andshock-resistance
Electromagneticcompatibility(EMC)
Process
Mediumtemperaturerange
Pressure-temperatureratings
Nominalpressureofsensor
Pressurespecifications
Pressureloss
Thermalinsulation
Mechanicalconstruction
DimensionsinSIunits
DimensionsinUSunits
Weight
Materials
Flangeconnections
Operability
Operatingconcept
Languages
Localoperation
Remoteoperation
Certificatesandapprovals
CEmark
RCM-ticksymbol
HARTcertification
PressureEquipmentDirective
Experience
Otherstandardsandguidelines
Applicationpackages
Wetsteamdetection
Wetsteammeasurement
Supplementarydocumentation
Standarddocumentation
Registeredtrademarks
TLVEXPRESSLIMITEDWARRANTY
Service

EF200R-C
3
About this document
slobmyslacirtcelEslobmyS
Symbol Meaning
Directcurrent
Alternatingcurrent
Directcurrentandalternatingcurrent
Groundconnection
Agroundedterminalwhich,asfarastheoperatorisconcerned,isgroundedviaa
groundingsystem.
ProtectiveEarth(PE)
Aterminalwhichmustbeconnectedtogroundpriortoestablishinganyother
connections.
Thegroundterminalsaresituatedinsideandoutsidethedevice:
• Innergroundterminal:Connectstheprotectivearthtothemainssupply.
• Outergroundterminal:Connectsthedevicetotheplantgroundingsystem.
Symbols for certain types of information
Symbol Meaning
Permitted
Procedures,processesoractionsthatarepermitted.
Preferred
Procedures,processesoractionsthatarepreferred.
Forbidden
Procedures,processesoractionsthatareforbidden.
Tip
Indicatesadditionalinformation.
Referencetodocumentation.
AReferencetopage.
Referencetographic.
Visualinspection.
Symbols in graphics
Symbol Meaning
1,2,3,... Itemnumbers
1. , 2. , 3. ,… Seriesofsteps
A,B,C,... Views
A-A,B-B,C-C,... Sections
Flowdirection

EF200R-C
4
Function and system design
Measuring principle VortexmetersworkontheprincipleoftheKarmanvortexstreet.Whenfluidflowspastabluffbody,
vorticesarealternatelyformedonbothsideswithoppositedirectionsofrotation.Thesevorticeseach
generatealocallowpressure.Thepressurefluctuationsarerecordedbythesensorandconvertedto
electricalpulses.Thevorticesdevelopveryregularlywithinthepermittedapplicationlimitsofthe
device.Therefore,thefrequencyofvortexsheddingisproportionaltothevolumeflow.
A0033465
Samplegraphic
Thecalibrationfactor(K-factor)isusedastheproportionalconstant:
K-Factor=
P
u
l
ses
UnitVolume[m³]
Withintheapplicationlimitsofthedevice,theK-factoronlydependsonthegeometryofthedevice.
ItisforRe>10000:
• Independentoftheflowvelocityandthefluidpropertiesviscosityanddensity
• Independentofthetypeofsubstanceundermeasurement:steam,gasorliquid
Theprimarymeasuringsignalislineartotheflow.Afterproduction,theK-factorisdeterminedin
thefactorybymeansofcalibration.Itisnotsubjecttolong-timedriftorzero-pointdrift.
Thedevicedoesnotcontainanymovingpartsanddoesnotrequireanymaintenance.
Thecapacitancesensor
Thesensorofavortexflowmeterhasamajorinfluenceontheperformance,robustnessand
reliabilityoftheentiremeasuringsystem.
TherobustDSCsensoris:
• burst-tested
• testedagainstvibrations
• testedagainstthermalshock(thermalshocksof150K/s)
Themeasuringdeviceusesthetried-and-tested,capacitancemeasuringtechnology,
whichisalreadyinuseinover450 000measuringpointsworldwide.Thankstoits
design,thecapacitancesensorisalsoparticularlymechanicallyresistanttotemperatureshocks
andpressureshocksinsteampipelines.

EF200R-C
5
Temperature measurement
Themeasuringdevicecanalsomeasurethetemperatureofthemedium.
ThetemperatureismeasuredviaPt1000temperaturesensors.Thesearelocatedinthepaddleof
theDSCsensorandarethereforeinthedirectvicinityofthefluid.
1
A0034068
1 DSCsensor
Pressureandtemperaturemeasurement
Themeasuringdevicecanalsomeasurethepressureandtemperatureofthefluid.
ThetemperatureismeasuredviaPt1000temperaturesensors.Thesearelocatedinthepaddleof
theDSCsensorandarethereforeinthedirectvicinityofthefluid.Pressuremeasurementislocated
directlyonthemeterbodyatthelevelofthebluffbody.Thepositionofthepressuretappingwas
chosensothatpressureandtemperaturecouldbemeasuredatthesamepoint.Thisenablesaccurate
densityand/orenergycompensationofthefluidusingpressureandtemperature.Themeasured
pressuretendstobesomewhatlowerthanthelinepressure.Forthisreason,TLVoffers
acorrectiontothelinepressure(integratedinthedevice).
Ordercodefor"Sensorversion;DSCsensor;measuringtube":
• Option"Masssteam;316L;316L(integratedpressure/temperaturemeasurement)"
Lifelongcalibration
Experiencehasshownthatrecalibratedmeasuringdevicesdemonstrateaveryhighdegreeof
stabilitycomparedtotheiroriginalcalibration:Therecalibrationvalueswereallwithintheoriginal
measuringaccuracyspecificationsofthedevices.Thisappliestothemeasuredvolumeflow,the
device'sprimarymeasuredvariable.
Varioustestsandsimulationhaveshownthatoncetheradiioftheedgesonthebluffbodyareless
than1mm(0.04in),theresultingeffectdoesnothaveanegativeimpactonaccuracy.
Iftheradiioftheedgesonthebluffbodydonotexceed1mm(0.04in),thefollowinggeneral
statementsapply(inthecaseofnon-abrasiveandnon-corrosivemedia,suchasinmostwaterand
steamapplications):
• Themeasuringdevicedoesnotdisplayanoffsetinthecalibrationandtheaccuracyisstill
guaranteed.
• Alltheedgesonthebluffbodyhavearadiusthatistypicallysmallerinsize.Asthemeasuring
devicesarenaturallyalsocalibratedwiththeseradii,themeasuringdeviceremainswithinthe
specifiedaccuracyratingprovidedthattheadditionalradiusthatisproducedasaresultofwear
andteardoesnotexceed1mm(0.04in).
Consequently,itcanbesaidthattheproductlineofferslifelongcalibrationifthemeasuringdeviceis
usedinnon-abrasiveandnon-corrosivemedia.

EF200R-C
6
1) o.r.=ofreading
Sensorswithintegratednominaldiameterreduction
Inmanyapplicationsthenominaldiameterofthecustomer'spipedoesnotmatchthenominal
diameterthatisoptimumforavortexmeter.Asaresult,theflowvelocityistoolowforvortex
formationafterthebluffbody.Thisisexpressedinsignallossinthelowerflowrange.Theflow
velocitycanbeincreasedbyreducingthenominaldiameterbyonesizes.Thisenablesthe
installationofthefollowingadapters:
AB
1234
A0034060
12
abc d
A0019070
A Nominaldiameterreductionbyinstallingvariousadaptersandpipesegmentsinthepipe
B NominaldiameterreductionbyusingtheProwirlwithintegratedlinesizereduction
1 Reducerelement
2 Straightpipesegmentastheinletrun(min.15×DN)upstreamfromthevortexmeter
3 Straightpipesegmentastheoutletrun(min.5×DN)downstreamfromthevortexmeter
4 Expansionelement
• EF200R-C":withsingleinnerdiameterlinesizereduction,e.g.fromDN80(3")toDN50(2")
Thesemodelsofferthefollowingbenefits:
Savingsintermsofcostandtime:theadditionaladaptersarereplacedentirelybyonesingledevice
• Measuringrangeextendedforlowerflowrates
• Lowerriskintheplanningphaseassamelengthsareusedcomparedtostandardflangeddevices
• Alldevicetypescanbeusedalternativelywithouttheneedforcomplicatedchangestothelayout
• Accuracyspecificationsidenticaltothoseforstandarddevices
Inletandoutletrunstobeconsidered→Seepage31.

EF200R-C
7
Measuring system Thedeviceconsistsofatransmitterandasensor.
Twodeviceversionsareavailable:
• Compactversion‒transmitterandsensorformamechanicalunit.
• Remoteversion-transmitterandsensoraremountedinseparatelocations.
Transmitter
EF200-C Deviceversionsandmaterials:
• Compactorremoteversion,aluminumcoated:
Aluminum,AlSi10Mg,coated
Configuration:
• Viafour-linelocaldisplaywithkeyoperationorviafour-line,
• Viaoperatingtools
A0013471
Sensor
EF200R-C
A0034075
Pressuremeasuringcell
1
A0034080
1 Pressuremeasuringcell
Versions:
Pressurecomponents
• Pressuremeasuringcell40bara
Material
• Wettedparts:
• Processconnection
Stainlesssteel,1.4404/316L
• Membrane
Stainlesssteel,1.4435/316L
• Non-wettedparts:
Housing
Stainlesssteel,1.4404
Flangedversionwithintegratednominaldiameterreduction:
• Twoversionswithadifferentnominaldiameterrangeareavailable:
• "R-type"withsingleinnerdiameterlinesizereduction:DN25Rto
200R(1Rto8R")
• Materials:
• MeasuringtubesDN15to150(½to6"):stainlesscaststeel,CF3M/
1.4408

EF200R-C
8
Input
Measured variable Directmeasuredvariables
Description Measuredvariable
Mass;316L;316L(integratedtemperaturemeasurement) • Volumeflow
• Temperature
Calculatedmeasuredvariables
Versionwithpressuremeasuringcell
Description Measuredvariable
Mass;316L;316L(integratedtemperaturemeasurement) • Correctedvolumeflow
• Massflow
• Calculatedsaturatedsteampressure
• Energyflow
• Heatflowdifference
• Specificvolume
Measuring range Themeasuringrangeisdependentonthenominaldiameter,thefluidandenvironmentalinfluences.
Thefollowingspecifiedvaluesarethelargestpossibleflowmeasuringranges(QmintoQmax )for
eachnominaldiameter.Dependingonthefluidpropertiesandenvironmentalinfluences,the
measuringrangemaybesubjecttoadditionalrestrictions.Additionalrestrictionsapplytoboth
thelowerrangevalueandtheupperrangevalue.
FlowmeasuringrangesinSIunits
DN
[mm]
Liquids
[m³/h]
Gas/steam
[m³/h]
25R 0.1to4.9 0.52to25
40R 0.32to15 1.6to130
50R 0.78to37 3.9to310
80R 1.3to62 6.5to820
100R 2.9to140 15to1800
150R 5.1to240 25to3200
200R 11to540 57to7300

EF200R-C
9
FlowmeasuringrangesinUSunits
DN Liquids Gas/steam
[in] [ft³/min] [ft³/min]
1R 0.061to2.9 0.31to15
1½R 0.19to8.8 0.93to74
2R 0.46to22 2.3to180
3R 0.77to36 3.8to480
4R 1.7to81 8.6to1100
6R 3to140 15to1900
8R 6.8to320 34to4300
Flowvelocity
D
i
v,Q
A0033468
DiInternaldiameterofmeasuringtube(correspondstodimensionK→Seepage41)
v Velocityinmeasuringtube
Q Flow
TheinternaldiameterofmeasuringtubeDiisdenotedinthedimensionsasdimension
K.→Seepage25.
Calculationofflowvelocity:
v[m/s]=
³
]h/m[Q·4
π·D [m]
i²·1
3600[s/h]
v[ /s]= 4 ·Q[ /min]ft³
π·D [ft]
i²·1
60[s/min]
A0034301

EF200R-C
10
Lowerrangevalue
Arestrictionappliestothelowerrangevalueduetotheturbulentflowprofile,whichonlyoccurs
withReynoldsnumbersgreaterthan5000.TheReynoldsnumberisdimensionlessandindicatesthe
ratiooftheinertiaforceofafluidtoitsviscousforcewhenflowingandisusedasacharacteristic
variableforpipeflows.InthecaseofpipeflowswithReynoldsnumberslessthan5000,periodic
vorticesarenolongergeneratedandflowratemeasurementisnolongerpossible.
TheReynoldsnumberiscalculatedasfollows:
Re =4·Q[m
³
/s]· [kg/m
³
]ρ
·D [m]·µ[Pa·s]π
i
Re =4·Q[ft³/s]· [lbm/ft³]ρ
·D [ft]·µ[lbf·s/ft ]π
i
²
A0034291
Re Reynoldsnumber
Q Flow
DiInternaldiameterofmeasuringtube(correspondstodimensionK→See41)
µ Dynamicviscosity
ρ Density
TheReynoldsnumber,5000togetherwiththedensityandviscosityofthefluidandthenominal
diameter,isusedtocalculatethecorrespondingflowrate.
Q [m /h]=
Re=5000 ³
5000 [Pa· ·D [m]· ·s]
i
πμ
· 3600[s/h]
4[kg/m]·³ρ
Q [ /h]=
Re=5000 ³
5000 [lbf· ·D [ft]· ·s/ft ]
i
²πμ
· 60[s/min]
4 [lbm/ ]· ³ρ
A0034302
QRe=5000 FlowrateisdependentontheReynoldsnumber
DiInternaldiameterofmeasuringtube(correspondstodimensionK→Seepage41)
µ Dynamicviscosity
ρ Density
Themeasuringsignalmusthaveacertainminimumsignalamplitudesothatthesignalscanbe
evaluatedwithoutanyerrors.Usingthenominaldiameter,thecorrespondingflowcanalsobe
derivedfromthisamplitude.Theminimumsignalamplitudedependsonthesettingforthe
sensitivityoftheDSCsensor(s),thesteamquality(x)andtheforceofthevibrationspresent(a).The
valuemfcorrespondstothelowestmeasurableflowvelocitywithoutvibration(nowetsteam)ata
densityof1kg/m3(0.0624lbm/ft^3).Thevaluemfcanbesetintherangefrom
6to20m/s(1.8to6ft/s)(factorysetting12m/s(3.7ft/s))withthe Sensitivityparameter(value
range1to9,factorysetting5).
Other manuals for EF200R-C
1
Table of contents
Other TLV Measuring Instrument manuals