P-04
display content: display switch between distance and liquid level, display distance
when “00” is set, display liquid level when “01”is set, factory debug model when “02” “03” is set,
factory debug model is not recommended for field use
P-05
filter time: the parameter is valid only if P-03 is set (level meter is under material level).
The higher the parameter value, the stronger
the signal filtering ability, but at the same time, which can reduce the response speed of level
meter, so the value between 3 and 5 is recommended.
Buttons Define
Change display content: press this button to enter password interface under the condition of
the main display interface; press this button to switch to the next parameter interface under
the condition of user parameter interface.
Press this button to enter setting state when entering password or modifying parameter is
required. At this time, the modified digit will flash, press again, flashing digit will add“1”.
The modified digit will move to the next digit, use
and
together to modify
parameter or enter password.
Press this button after finishing modifying parameter, press again to return the main display
interface.
Parameter Setting (password: 3456)
Operation Steps
Under the main display interface, Press , password entry interface will appear after PASS
appears, at this time, use and together, enter password “3456”, press again,
P-00(ullage) interface will appear; Use and together to modify parameter value, press
after finish setting, press to switch to the next parameter interface If nextparameter
is required to modify. Press to return the main display interface after finish modifying all
parameter, then level meter enters measurement state. Most of the time, enter P-00 ullage and P-
01 full scale value, then the level meter can work well.