SV 100A User Guide
SV100A Technical Specification
The policy of our company is to continually innovate and develop our products.
Therefore, we reserve the right to change the specifications without prior notice.
Application Whole-body
Standards ISO 8041:2005, ISO 2631-1:1997
Meter Mode aw (RMS), awmax (RMS MAX), VDV, MaxVDV, awv (VECTOR), A(8) Daily Exposure, A(8) Daily Exposure,
ELV Time (TIME LEFT TO LIMIT), ELV Time (TIME LEFT TO LIMIT), EAV Time (TIME LEFT TO ACTION)
EAV Time (TIME LEFT TO ACTION); MTVV, Max, Peak, Peak-Peak
Filters Wd, Wk, Wm, Wb (ISO 2631) and corresponding Band Limiting filters
Wf for motion sickness filter measurements according to ISO 2631-1 (option)
RMS & RMQ Detectors Digital true RMS & RMQ detectors with Peak detection, resolution 0.1 dB
Measurement Range 0.01 ms-2 RMS ÷ 157 ms-2 PEAK
Frequency Range 0.1 Hz ÷ 180 Hz
Data Logger Time-history data including meter mode results and spectra
Time-Domain Recording Simultaneous 3-channel time-domain signal recording (option)
Analyser 1/1 octave real-time analysis (option)
1/3 octave real-time analysis (option)
Accelerometer Built-in tri-axial MEMS based
Display OLED 128 x 32 pixels
Memory 8 GB
Interfaces USB 2.0 client, Bluetooth
Keyboard 4 push buttons
Power Supply
Ni-MH rechargeable cells operation time > 24 hours1
USB interface 500 mA HUB
Environmental Conditions
Temperature from -10 oC to 50 oC
Humidity up to 90 % RH, non-condensed
Dimensions o
/ 235mm x 12 mm
Weight 0.5 kg
1dependent on instrument operation configuration