Starrett 3754 User manual

Trust Is In The Name User Manual
PKG08762- UM3754

2 PKG08762-UM3754 12/15 PDF
READ THIS MANUAL BEFORE USING THE INSTRUMENT
ANTES DE UTILIZAR EL INSTRUMENTO,
LEA ATENTAMENTE ESTE MANUAL
LIRE CE MANUEL AVANT D'UTILISER L'INSTRUMENT
LEIA ATENTAMENTE ESTE MANUAL ANTES
DE UTILIZAR O INSTRUMENTO
使用仪器前请阅读本操作手册
DIESES HANDBUCH VOR DER VERWENDUNG
DES MESSGERÄTS LESEN
LEGGERE ATTENTAMENTE QUESTO MANUALE PRIMA
DI UTILIZZARE QUESTO STRUMENTO

PKG08762-UM3754 3
3754 ELECTRONIC HEIGHT GAGE
USER MANUAL

4 PKG08762-UM3754
TABLE OF CONTENTS
Components 5
Specifications 8
Operating Instructions 9
New Battery, Startup Sequence 11
Installing the Batteries 13
Description of the Button Functions 14
Setting the PRESET/ABS Function 15
Setting Limits (Go/No Go Function) 16
Data Output 17
Mounting a 3808MA Test Indicator 18
Accessories 19
Cautions on Use 19
Service Information 20
Spanish 21
French 35
Italian 49
German 63
Chinese 77
Portuguese 91

PKG08762-UM3754 5
COMPONENTS
1. Scribe
- Trazador
- Pointe à tracer
- Marcatura
- Schreiber
-量测探针
- Traçador
2. Lock
- Tornillo de fijación
- Vis de blocage
- Blocco
- Sperre
-锁定装置
- Tranca
3. Display
- Pantalla
- Affichage
- Schermo
- Anzeige
-显示屏
- Visor
4. Column
- Columna
- Colonne
- Colonna
- Ständer
-支撑柱
- Coluna
5. Hardened Base
- Base templada
- Socle renforcé
- Base rinforzata
- Gehärteter Sockel
-固定座
- Base rígida
1
5
3
2
4


PKG08762-UM3754 7
3754 ELECTRONIC HEIGHT GAGE
THIS IS A STARRETT USER GUIDE FOR THE 3754 DIGITAL HEIGHT GAGE.
ALL SPECIFICATIONS IN THIS DOCUMENT ARE CORRECT AT TIME
OF PRODUCTION AND ARE SUBJECT TO CHANGE. PLEASE CONTACT
STARRETT FOR FURTHER INFORMATION.

8 PKG08762-UM3754
ENGLISH
SPECIFICATIONS
MODEL INCH MILLIMETER
Measuring Range 12" 0-12 0-300
24" 0-24 0-600
Accuracy
12" ±.0015 ±0.04mm
24" ±.0015 (0-18") ±0.04mm
±.002 (18"-24") ±0.05mm
Resolution .0005" .01mm
Power Source Batteries - Lithium coin cells 3V (2), No. CR232 equivalent
1-1/2 years battery life with average use.
Serial Data 4800 BAUD, 8 data bits, no pairity, 1 stop bit
Fine Adjustment Lock
Data Port
Battery
Scriber
Back
Scriber Clamp
Fine Adjusting Nut
Main Slide Lock

PKG08762-UM3754 9
ENGLISH
OPERATING INSTRUCTIONS
GETTING STARTED
1. IMPORTANT: To start, please read through steps 3 and 4 below and familiarize
yourself with the setup of the gage.
2. Clean the bottom of the height gage and the surface plate or reference surface
being used.
3. Install the batteries that came with the height gage. Refer to "Battery Drawer
Removal" and "Battery Replacement" on page 13.
NOTE: When the new batteries are inserted into the gage, the gage will automatically
turn on, and go through a startup sequence. See step 4 below
4. Follow the instructions "New battery, Startup Sequence" and the "New Datum/
Zero Reference, Setup" section on page 11.
5. The gage is now ready to measure. You can turn on the height gage with the On/
Off button or move the slide.
6. The gage will automatically turn off (the display will go blank) after 20 minutes of
no slide movement or pressing of a button. Any movement of the slide will activate
the display with no loss of position reading.
TO ESTABLISH A ZERO REFERENCE USING AN INDICATOR
7. Ideally an indicator should be mounted on the height gage with the proper
attachment (PN: 99454 not supplied) to use as a positioning device. A test indicator
can be used if the part configuration will allow.
8. The reference zero position can be the surface plate itself, a gage block or a
reference surface on the product part.
9. Loosen the lock on the gage slide and carrier, then move the slide to a position
where the indicator contact is slightly above the zero reference surface but not
touching it. Using the fine adjustment knob, move the slide until a reading is
displayed on the indicator. Move the fine adjustment until the indicator reads zero.
10. Zero the Gage by pressing the Zero/ABS button. Now when you measure parts, the
indicator will make sure that the pressure on the part being measured is always
the same.
NOTE: If using a dial indicator, be sure to count revolutions of the indicator hand. If using
a digital Indicator, depress the ZERO button to change the display to a zero position
"0.0000" (0.00mm).

10 PKG08762-UM3754
ENGLISH
USING A SCRIBER
11. The special scriber furnished with the height gage can be mounted using the
scriber clamp.
12. Allow the scriber to contact the surface that will be your zero reference.
13. Operation of the height gage is the same as noted above in "To Establish a Zero
Reference Using an Indicator" and below "Height Measurement".
NOTE: Use of the scriber to contact work surfaces depends on the ability of the operator to
"feel" the contact surface without exerting excess pressure on the surface with the scriber.
HEIGHT MEASUREMENT
14. Loosen the lock on the gage slide and the fine-adjust, and then move the gage into
position so that the indicator contact is directly over the surface to be measured.
15. Using the fine adjustment mechanism, move the slide until the indicator reads zero.
16. The display will show the exact dimension of the surface or feature being measured
with reference to the zero position or datum you set up.
Table of contents
Languages: