sirea AEA 5000 User manual

AEA 5000
Installation and user
manual
Document name SIR-AEA5000-EN-REV0
Date of publication 2022-01-11

AEA 5000 - Self-consumption cabinet with storage
Contents
2
1. Product presentation
3
3
4
5
6
6
6
6
7
1.1 Dimensions
1.2 Description of the front panel controls
1.3 Fault list
1.4 Safety instructions and warnings
1.5 Protective device
1.6 Disposal
1.7 Cleaning
1.8 Identification of the AEA 5000
1.9 Functional principle
8
2. Commissioning of the cabinet
9
9
2.1 Installing the batteries
2.2 Installation of batteries
9
9
9
10
10
11
11
11
12
2.2.1 Removing the front door
2.2.2 Inserting several batteries
2.2.3 Connecting the batteries
2.2.4 Connecting the communication cable 2.2.5
Connecting to the mains
2.2.6 Connecting the measuring torus
2.2.7 Connecting the photovoltaic panels 2.2.8
Switching on the batteries
2.2.9 Option: Router setup
12
15
15
15
16
2.3 Option: Hot water tank management
2.3.1 Hot water tank control
2.3.2 Hot water tank connection (max. 20A)
2.4 Option: Mains energy sales
2.5 Option: Backup output
16
16
2.5.1 Management of the standby output
2.5.2 Connecting the safety output 16
3. Putting into operation 17
17
17
3.1 Switching on/off
3.2 Functional check
Contacts 18
SIR-AEA5000-EN-REV0
PAGE 2 / 18

AEA 5000 - Self-consumption cabinet with storage
1. Product presentation
The AEA 5000 cabinet was developed with the aim of delivering a reliable power supply from various
sources of conventional and renewable energy.
This cabinet promotes self-production and facilitates self-consumption of the electrical energy
generated, in order to reduce the consumption of electricity from the electrical network.
The AEA 5000 cabinet offers the possibility of measuring and optimizing a single-phase consumption
point and controlling a resistive domestic hot water tank (option).
1.1 Dimensions
AEA 5000 Slim
AEA 5000+
Warning
Do not put anything on it.
Leave a clearance of at least 5 cm on the sides and back of the cabinet, and at least 20 cm
above the cabinet.
SIR-AEA5000-EN-REV0
PAGE 3 / 18

AEA 5000 - Self-consumption cabinet with storage
1.2 Description of the front panel controls
Icon Comment
Solar indicator
Green fixe: production in progress but production below consumption
Slow flashing green: production in progress, production covers the needs
of the dwelling, the surplus is charged into the battery
Fast flashing green: production in progress, production covers the needs
of the dwelling, the surplus is charged into the battery and the remaining
surplus is injected into the grid
Flashing red: emergency mode (optional)
Red fixe: cabinet stopped or no mode selected
Off: no production
Battery indicator
Flashing green: charging in progress
Green fixe: discharge in progress
Unlit: no charging or discharging
Red fixe: battery low or other battery fault
Warning light
Unlit: no fault
Red fixe: at least one fault present
Remote management light
Green fixe: communication with the server in progress
Red: server connection error
Unlit: no IP address received (no DHCP connection to the box)
WiFi indicator
Solid green: Wi fi network detected
Off: Wi fi network not detected
/
Voyant mode
Green fixe: Affichage SOC (level) battery in progress (temporary
affichage following button press).
Off: Affichage standard in progress
SIR-AEA5000-EN-REV0 PAGE 4 / 18

AEA 5000 - Self-consumption cabinet with storage
1.3 List of faults
Intitulé
Action
Lightning fault Check the condition of the PF10 / PF20 arresters
RS485 communication fault with the inverter Check the connections between the inverter and
the PLC (OND1 / API1)
RS485 communication fault with the BMS A16 Verify the connections between PLCs (PLC1 / PLC2)
Unit start-up fault Check the status of the AC circuit breaker
QF10, the generator set and the connections
PV fault (24h without production) Check the status of the PV circuit breaker QF20
RS485 communication fault with the dimmer Verify the connections between PLCs (PLC1 /
GDT1)
CAN communication fault between BMS A16 and battery Verify the connections between PLC and battery
(PLC2 / BAT)
CAN communication fault between BMS A16 and
inverter
Verify connections between PLC and inverter
(PLC2 / OND1)
Battery fault EMSAbsent
Restart the batteries by switching off QF30
Battery fault IBMSConfigurationProblem
Battery fault NumberOfSlaveProblem
Battery fault PowerBusInformation
Low battery voltage
Battery voltage high
Battery fault GlobalIBMSAlarmState
Inverter fault FaultList
Restart by switching off all circuit breakers, wait
1mn then restart
Inverter Fault Inverter Alarm Information
Inverter fault Internal Information
Inverter Fault Battery Fault Information
Inverter Fault PackFaultSN
BMS fault wFaultAutomateSyst
Restart the batteries by switching off QF30
BMS fault wFaultBmsSyst
BMS Fault0_7
BMS Fault Fault8_15
BMS Fault16_23
BMS Fault24_31
BMS Fault32_35
Low battery temperature Check the room temperature
Low battery level Alert
Low battery health level (SOH) Alert
High battery temperature Check the room temperature
High temperature Dimmer heatsink NTC Check the room temperature and check the state of
the ventilation
Dimmer internal NTC high temperature
WIFI detection fault Check the connections
SIR-AEA5000-EN-REV0
PAGE 5 / 18

AEA 5000 - Self-consumption cabinet with storage
1.4 Safety instructions and warning
Attention
Any damage resulting from non-compliance with this user manual will void the warranty! We do
not accept any liability for damage to property or personal injury caused by incorrect handling or
failure to observe the safety instructions.
From a safety point of view, this equipment has left the factory in perfect condition. In order to
maintain this equipment in good condition and to ensure its correct use without risk, the user must
observe the safety instructions and warnings contained in this manual. In industrial installations, the
accident prevention regulations for electrical installations and equipment must be observed.
The installation of this type of equipment must always be carried out by a competent professional.
Opening covers or disassembling parts may expose live parts; before working on the equipment, it
must be disconnected from all voltage sources. However, the unit's capacitors may still be charged
even when the AEA3000+ has been disconnected. The AEA3000+ cabinet must be installed in a room
with an ambient temperature. If the unit is no longer functioning properly, it should be disconnected
from the power supply and prevented from being switched on again. In this case, contact your
installer.
Please observe the following pictograms:
Caution. On the product label,
this symbol indicates that the
notice must be consulted. In
this manual, this symbol
indicates important
information.
Direct current
This device is CE approved and
complies with national and
European guidelines.
1.5 Protective device
A short circuit protection system must be fitted to the 24 volt DC supply to the PLC. These fuses shall
be sized according to the number of devices in series behind the feeder.
1.6 Elimination
Old electronic devices are recyclable products that should not be thrown in the trash. If
the device reaches the finish of its life, it must be disposed of in accordance with the legal
regulations in force at the recovery centres in your municipality. Disposal in household
waste is prohibited.
1.7 Cleaning
For cleaning, use a clean, dry, antistatic, lint-free cloth without corrosive products.
SIR-AEA5000-EN-REV0
PAGE 6 / 18

AEA 5000 - Self-consumption cabinet with storage
1.8 Identification of the AEA 5000
To identify the AEA 5000, a label with a barcode is attached to the inside of the cabinet door. The
serial number (SN) is shown in the third row of the table.
SIR-AEA5000-EN-REV0
PAGE 7 / 18

AEA 5000 - Self-consumption cabinet with storage
1.9 Operating principle
Energy from the renewable source is used for consumption as a priority. If there is excess energy
production, it is stored in the battery. If the battery reaches a full charge level, the power of the panel
will be limited so as not to send power to the grid (in case of sale to the grid, refer to paragraph 2.4)
For the case where the renewable energy production is insuffisante, the additional energy needed for
consumption is provided primarily by the battery. If the battery reaches a low charge level, the
missing energy is drawn from the power grid.
In case the demand is higher than the maximum power of the cabinet, the additional power is
supplied by the grid.
SIR-AEA5000-EN-REV0
PAGE 8 / 18

AEA 5000 - Self-consumption cabinet with storage
2. Commissioning
2.1 Installation of the batteries
The AEA 5000 cabinet is designed to accommodate Phenix Batteries. For further information on the
batteries, please refer to the enclosed manual. The batteries are delivered with their power cables.
The communication cable to be connected to the battery is already connected in the cabinet.
2.2 Installation of batteries
Caution
Before dismantling the door, make sure that the power sources are switched off via all
circuit breakers.
2.2.1 Removing the front door
1. Unscrew the 4 screws above the cabinet and lift the roof.
2. Pull out the front of the cabinet
2.2.2 Installing several batteries
1. Slide the battery on the guide rails to the bottom to leave room for
the next one. Facing the cabinet, the DB9 communication socket should be
on the left.
2. Slide the second battery onto the guide rails, always with the DB9
socket on the left.
SIR-AEA5000-EN-REV0
PAGE 9 / 18

AEA 5000 - Self-consumption cabinet with storage
2.2.3 Connecting the batteries
Connect the black connectors to black terminals and the orange connectors to orange terminals
2.2.4 Connection of the communication cable
Connect the communication sockets (multicolored cable). The plug at the end of the cable should go
to the DB9 socket on the back battery and the other socket closest to the front panel.
Caution
Make sure that the plugs are correctly inserted.
SIR-AEA5000-EN-REV0
PAGE 10 / 18
Table of contents
Other sirea Industrial Equipment manuals