Rothenberger RO 458s User manual

1ENGLISH
RO 458s
rothenberger.com
MAN00148
RO 458s
EN Instructions for use

2ENGLISH
Contents Page
Table of contents UK
1 RO 458s Overview 4
2 Analyser Features and Keypad 6
2.1 RO 458s Buttons 7
2.2 Analyser Layout 8
3 Batteries 10
3.1 Replacing batteries 10
3.2 Time & date 10
3.3 Charging NIMH batteries 10
3.4 Battery disposal 10
4 General Safety 11
4 Using your RO 458s for the first time 12
4.1 Using your RO 458s every time 12
4.2 Fresh air purge switch on 12
5 Using the menu 14
6 Measuring flue gasses 16
7 CO protection pump operation 17
7 CO protection pump operation 17
8 Using your analyser 17
8.1 Combustion tests 17
8.2 Ratio display 18
8.3 O2/Eff display 18
9 Transferring results 19
8.4 AUX display 19
9.1 To view/print a logged report 19
9.2 Viewing/printing a logged combustion test 20
9.3 Kane infrared printer 20
9.4 Printouts 21
10 Commissioning test 22
11 Pressure & temperature testing 23
11.1 Pressure measurement good practice 24
11.2 Large bore tubing issues 24
1 RO 458S OVERVIEW..............................................4
2 ANALYSER FEATURES AND KEYPAD ....................6
2.1 RO 458S BUTTONS..........................................................7
2.2 ANALYSER LAYOUT ........................................................8
3 BATTERIES ...........................................................10
3.1 REPLACING BATTERIES .................................................10
3.2 TIME & DATE.................................................................10
3.3 CHARGING NIMH BATTERIES .......................................10
3.4 BATTERY DISPOSAL......................................................10
4 GENERAL SAFETY ...............................................11
5 USING YOUR RO 458S FOR THE FIRST TIME ......12
5.1 USING YOUR RO 458S EVERY TIME..............................12
5.2 FRESH AIR PURGE SWITCH ON ....................................12
6 USING THE MENU ...............................................14
7 MEASURING FLUE GASSES.................................16
8 CO PROTECTION PUMP OPERATION ..................17
9 USING YOUR ANALYSER.....................................17
9.1 COMBUSTION TESTS.....................................................17
9.2 RATIO DISPLAY.............................................................18
9.3 O2/EFF DISPLAY............................................................18
9.4 AUX DISPLAY ................................................................19
10 TRANSFERRING RESULTS ...................................19
10.1 TO VIEW/PRINT A LOGGED REPORT............................19
10.2 VIEWING/PRINTING A LOGGED COMBUSTION TEST .....20
10.3 KANE INFRARED PRINTER ............................................20
10.4 PRINTOUTS ...................................................................21
11 COMMISSIONING TEST .......................................22
12 PRESSURE & TEMPERATURE TESTING ................23
12.1 PRESSURE MEASUREMENT GOOD PRACTICE ..............24
12.2 LARGE BORE TUBING ISSUES.......................................24
13 LET-BY & TIGHTNESS TESTING ...........................25
14 ROOM CO TESTING .............................................27

ENGLISH 3
14.1 TEST TYPES....................................................................27
14.2 ROOM CO DISPLAY.......................................................28
15 USING YOUR RO 458S AS A THERMOMETER OR
PRESSURE METER .........................................................28
16 ANALYSER PROBLEM SOLVING .........................29
17 SPECIFICATIONS .................................................30
18 EU DECLARATION OF CONFORMITY.................32
19 COLD WEATHER PRECAUTIONS ........................33

4ENGLISH
Your RO 458s combustion analyser measures:
●Carbon Monoxide (CO)
●Carbon Dioxide (CO2)
●Oxygen (O2) if fitted
●Nitric Oxide (NO) if fitted
●Differential Pressure
●Differential temperature
Your RO 458s measures CO2 using KANE’s unique NDIR sensor.
Always use fresh outdoor air to “zero” your analyser during the initial
countdown or when prompted to “ZERO CO2” as indoor CO2 levels are
increased by human activity.
This applies even if your analyser measures O2 instead of CO2 as it is best
practice to use fresh, outdoor air during initial countdown to protect you
from unsafe levels of CO & CO2 possibly present in the room.
Depending on your options these parameters are calculated:
●Oxygen (O2)
●CO/CO2 ratio
● Carbon Monoxide (CO2)
●Combustion Efficiency
●Losses
●Excess Air
●Differential Temperature
Your analyser also measures CO levels in ambient air – useful when a CO
alarm is triggered – & performs a Room CO test for up to 30 minutes.
Your RO 458s has a structured Commissioning Test to help install boilers.
Your RO 458s has a protective rubber cover with magnets for
“hands-free” operation & is supplied with a flue probe with integral
temperature sensor.
Your analyser has a low flow detector to switch off the analyser’s pump if it
detects an over filled water trap.
1 RO 458s Overview

ENGLISH 5
Your RO 458s has a large 6 line display showing data & test results based on
your actions.
Your RO 458s can send test results to our optional KANE IRP-2
infrared printer or KANE’s wireless printer App.
The memory can store up to:
●60 combustion tests
●20 AUX tests
●20 let-by/tightness tests
●20 temperature & pressure tests
● 20 room CO tests
● 20 commissioning Tests
You can personalise 2 lines of 16 characters on your test results header - for
example your company name & telephone number.

6ENGLISH
2 Analyser Features and Keypad

ENGLISH 7
2.1 RO 458s Buttons
Function keys
ICON Description Icons
Save log – long press to store data
Print report – short press to enter a print or wireless data transfer
Navigate up – short press to scroll up
Enter key – used to select current option
Navigate down – short press to scroll down
Data hold – short press to hold current data on screen
Pump toggle – long press to switch pump on & off

8ENGLISH
2.2 Analyser Layout
On / Off
Function keys
– see below
Water trap &
particle filter
Rotary switch
Battery
charger
Watertrap drain
with red plug
Flue probe
temperature T1
Inlet temperature T2
Pressure
connection P1
Pressure connection
P2 – differential
Flue gas inlet
Red connector
– plugs into Flue
Gas Inlet
Flue Probe Temperature Plug
– into T1
Narrow (+ve) pin must be on
right side Flue Probe Hose

ENGLISH 9
Watertrap
drain with red
plug
Thermocouple
Stainless Steel
Shaft
Depth Stop Cone
Gas Path
Magnets x2
Thermocouple
wire

10 ENGLISH
Your RO 458s uses rechargeable Nickel Metal Hydride (NiMH)
batteries - using other battery types may void your RO 458s’ warranty.
Warning
Although you can use Alkaline batteries you must not charge your analyser
with Alkaline batteries fitted.
Do not mix NiMH batteries of different capacities or from different
manufacturers – all must be identical.
Turn over your analyser & remove its protective rubber cover. Open the bat-
tery compartment & fit 3 NiMH “AA” rechargeable batteries – check battery
polarity is correct. Replace battery cover & protective rubber cover.
After changing the batteries reset your analyser’s time & date.
Your RO 458s uses a standard Micro USB connector for charging (KANE part
No: USB1).
For best results turn off your analyser then connect your charger – the
charging indicator illuminates & turns off when charging finishes.
Your first charge should be for 8 hours continuously – thereafter NiMH bat-
teries can be topped up at any time, even for short periods.
If the analysers batteries discharge & the analyser enters a ‘low power shut
down’ a 1 hour charge will provide approx 2 hours continuous use.
A
Always dispose of depleted batteries using approved disposal methods that
protect the environment.
3 Batteries
3.1 Replacing batteries
3.2 Time & date
3.3 Charging NIMH batteries
3.4 Battery disposal
Table of contents
Other Rothenberger Measuring Instrument manuals

Rothenberger
Rothenberger ROTEST GW 150/4 User manual

Rothenberger
Rothenberger RO 3200 User manual

Rothenberger
Rothenberger RO 77 User manual

Rothenberger
Rothenberger ROLEAK Pro User manual

Rothenberger
Rothenberger Roscope 1000 User manual

Rothenberger
Rothenberger ROLEAK Pro User manual

Rothenberger
Rothenberger ROLeak Aqua 3Plus User manual