SPECIFICATIONS
1. DISPLAY: 6 digit, 0.56" (14.2 mm) red LED
2. POWER:
AC Versions (PAXC0000):
AC Power: 85 to 250 VAC, 50/60 Hz, 12 VA
Isolation: 2300 Vrms for 1 min. to all inputs and outputs. (300 V working)
DC Versions (PAXC0010):
DC Power: 11 to 36 VDC, 7 W
AC Power: 24 VAC, ± 10%, 50/60 Hz, 9 VA
Isolation: 500 Vrms for 1 min. to all inputs and outputs (50 V working)
3. SENSOR POWER: 12 VDC, ±10%, 100 mA max. Short circuit protected.
4. ANNUNCIATORS:
A - Counter A
B - Counter B
C - Counter C
!" - Upper significant digit display of counter
SP1 - Setpoint 1 Output State
SP2 - Setpoint 2 Output State
SP3 - Setpoint 3 Output State
SP4 - Setpoint 4 Output State
5. KEYPAD: 3 programmable function keys, 5 keys total.
6. COUNTER DISPLAYS:
Maximum display: 8 digits: ± 99999999 (greater than 6 digits display
alternates between high order and low order.)
7. MAXIMUM SIGNAL FREQUENCIES:
To determine the maximum frequency for the input(s), first answer the
questions with a yes (Y) or no (N). Next determine the Count Mode to be
used for the counter(s). If dual counters are used with different Count Modes,
then the lowest frequency applies to both counters.
Notes:
1. Counter Modes are explained in the Module 1 programming section.
2. Listed values are with frequency DIP switch set on HI frequency.
8. INPUTS A and B:
DIP switch selectable to accept pulses from a variety of sources including switch
contacts, outputs from CMOS or TTL circuits, and all standard RLC sensors.
LOGIC: Input trigger levels VIL = 1.5 V max.; VIH = 3.75 V min.
Current sinking: Internal 7.8 KΩpull-up to +12 VDC, IMAX = 1.9 mA.
Current sourcing: Internal 3.9 KΩpull-down, 7.3 mA max. @ 28 VDC,
VMAX = 30 VDC.
Filter: Damping capacitor provided for switch contact bounce. Limits
input frequency to 50 Hz and input pulse widths to 10 msec. minimum.
DUAL COUNT MODES:
When any dual count mode is used, then User Inputs 1 and/or 2 will accept
the second signal of each signal pair. The user inputs do not have the
Logic/Mag, HI/LO Freq, and Sink/Source input setup switches. The user
inputs are inherently a logic input with no low frequency filtering. Any
mechanical contacts used for these inputs in a dual count mode must be
debounced externally. The user input may only be selected for sink/source
by the User Jumper placement.
9. USER INPUTS: Three programmable user inputs
Max. Continuous Input: 30 VDC
Isolation To Sensor Input Commons: Not isolated
Logic State: Jumper selectable for sink/source logic
Response Time: 6 msec. typical; function dependent. Certain resets, stores
and inhibits respond within 25 µsec if an edge occurs with the associated
counter or within 6 msec if no count edge occurs with the associated
counter. These functions include #$%&$', #$%&$(, )*+),$, and &$!%(.
Once activated, all functions are latched for 50 msec min. to 100 msec
max. After that period, another edge/level may be recognized.
10. SETPOINT OUTPUT CARD:
Dual Relay Card:
Type: Two FORM-C relays
Isolation To Sensor & User Input Commons: 2000 Vrms for 1 min.
Working Voltage: 240 Vrms
Contact Rating:
One Relay Energized: 5 amps @ 120/240 VAC or 28 VDC (resistive load),
1/8 HP @ 120 VAC, inductive load
Total current with both relays energized not to exceed 5 amps
Life Expectancy: 100 K cycles min. at full load rating. External RC
snubber extends relay life for operation with inductive loads
Response Time: 5 msec. nominal with 3 msec. nominal release
Time Accuracy: ± 0.01% + 10 msec.
Quad Relay Card:
Type: Four FORM-A relays
Isolation To Sensor & User Input Commons: 2300 Vrms for 1 min.
Working Voltage: 250 Vrms
Contact Rating:
One Relay Energized: 3 amps @ 250 VAC or 30 VDC (resistive load),
1/10 HP @ 120 VAC, inductive load
Total current with both relays energized not to exceed 4 amps
Life Expectancy: 100 K cycles min. at full load rating. External RC
snubber extends relay life for operation with inductive loads
Response Time: 5 msec. nominal with 3 msec. nominal release
Time Accuracy: ± 0.01% + 10 msec.
Quad Sinking Open Collector Card:
Type: Four isolated sinking NPN transistors
Isolation To Sensor & User Input Commons: 500 Vrms for 1 min.
Working Voltage: 50 V. Not isolated from all other commons.
Rating: 100 mA max. @ VSAT = 0.7 V max. VMAX. = 30 V
Response Time: 25 µsec
Time Accuracy: ± 0.01% + 10 msec.
Quad Sourcing Open Collector Card:
Type: Four isolated sinking PNP transistors
Isolation To Sensor & User Input Commons: 500 Vrms for 1 min.
Working Voltage: 50 V. Not isolated from all other commons.
Rating: Internal supply: 24 VDC ± 10%, 30 mA max. total
External supply: 30 VDC max. 100 mA each output
Response Time: 25 µsec
Time Accuracy: ± 0.01% + 10 msec.
11. MEMORY: Non-volatile E2Prom retains all programming parameters and
display values.
12 CERTIFICATIONS AND COMPLIANCE:
SAFETY
EN 61010-1, IEC 1010-1
Safety requirements for electrical equipment for measurement, control,
and laboratory use, Part I
ELECTROMAGNETIC COMPATIBILITY
Note:
Refer to the EMC Installation Guidelines section of this bulletin for
additional information.
13. ENVIRONMENTAL CONDITIONS:
Operating Temperature Range: 0 to 50°C
Storage Temperature range: -40 to 60°C
Operating and Storage Humidity: 0 to 85% max. non-condensing
Altitude: Up to 2000 meters
14. CONNECTIONS: High compression, cage-clamp terminal block
Wire Strip Length: 0.3" (7.5 mm)
Wire Gauge Capacity: One 14 AWG (2.55 mm) solid, two 18 AWG (1.02
mm), or four 20 AWG (0.61 mm).
15. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 indoor use. IP20
Touch safe. Installation Category II, Pollution Degree 2. One piece
bezel/case. Flame resistant. Synthetic rubber keypad. Panel gasket and
mounting clip included.
16. WEIGHT: 10.1 oz (295 g)
2
VIN > 2.5 VDC VIN < 0.7 VDC
Inactive VIN < 0.7 VDC VIN > 2.5 VDC
Active
SINKING INPUTS
5.1 KΩΩpull-up to +12 V SOURCING INPUTS
5.1 KΩΩpull-down
INPUT STATE
Power mains class A
Enclosure class AEN 55011RF interference
Emissions to EN 50081-2
150 KHz - 80 MHz
Level 3; 10 V/rmsEN 61000-4-6RF conducted interference Level 3; 2 Kv power
Level 4; 2 Kv I/OEN 61000-4-4Fast transients (burst) 80 MHz - 1 GHz
Level 3; 10 V/mEN 61000-4-3Electromagnetic RF fields Level 3; 8 Kv airEN 61000-4-2Electrostatic discharge
200 Hz, 50% duty cycle
900 MHz ±5 MHz
Immunity to EN 50082-2
Level 3; 10 V/mENV 50204Simulation of cordless telephones
Single: Counter A or B Dual: Counter A&B
Are any setpoints used? N N Y Y N N Y Y
Is Counter C used? N Y N Y N Y N Y
COUNT MODE (Values are in KHz) (Values are in KHz)
Count x1 34 25 18 15 13 12 97.5
Count x2 17 13 9 7 9 7 5 4
Quadrature x1 22 19 12 10 7 6 4 3.5
Quadrature x2 17 13 9 7 7 6 4 3.5
Quadrature x4 8 6 4 3
FUNCTION QUESTIONS