REED R8010 User manual

reedinstruments
www com
Model R8010
Instruction
Manual
INSTRUMENTS
INSTRUMENTS
Laser Distance
Meter
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
2
INSTRUMENTS
INSTRUMENTS
Table of Contents
Safety ......................................................................................................... 3
Features...................................................................................................... 3
Specications............................................................................................. 4
Instrument Description ............................................................................... 5
Display Description .................................................................................... 5
Operating Instructions...........................................................................6-10
Measuring Range .................................................................................... 6
Target Surfaces ....................................................................................... 6
On and Off............................................................................................... 6
Clear Button ............................................................................................ 6
Reference Level Setting ........................................................................... 6
Backlight ................................................................................................. 7
Distance Unit Setting ............................................................................... 7
Single Distance Measurement ................................................................. 7
Continuous (Tracking)/Max & Min Measurement ...................................... 7
Addition/Subtraction................................................................................ 8
Area Measurement .................................................................................. 8
Volume Measurement.............................................................................. 8
Indirect Measurement.............................................................................. 9
Three Point Measurement ....................................................................... 9
Measurement Storage ........................................................................... 10
Troubleshooting..................................................................................... 10
Care ...................................................................................................... 10
Battery Replacement................................................................................ 10
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
3
INSTRUMENTS
INSTRUMENTS
Safety
• Readandfollowmanualinstructionsbeforeusingthisinstrument
• Donotusethisinstrumentoutsidethestatedspecications
• Donotdeactivatethesafetysystemsorremoveexplanatoryand
hazardlabels
• Donotopenthisinstrumentwithanytoolsunlessspecically
indicatedtodosointhismanual
• Donotmodifyorchangetheproductinanyway
• Donotaimdirectlytowardsthesun
• Donotstareintothelaserbeamordirectittowardsothers
Features
• Designedforone-handedoperation
• Userselectableunitofmeasure(imperial/metric)
• Lasertargetpointer
• Referencepointselection(frontorrearofinstrument)
• Backlitmulti-lineLCDdisplay
• CalculatesArea,VolumeandSumofLengths
• Addition,Subtractionandindirect2/3point(Pythagoras)calculations
• Max/Minfunctions
• Continuousmeasurementmode
• Internalmemorysavesupto20readings
• Dustandsplash-proof(IP54)
• Lowbatteryindicatorandautoshutoff
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
4
INSTRUMENTS
INSTRUMENTS
Specifications
MeasuringRange 1.92”to328’(5cmto100m)
Accuracy ±0.06”(1.5mm)
MeasuringUnits Meters,inches,feet
SensorType Laser
Display LCD(multi-line)
BacklitDisplay Yes
StartPointSelection Yes(Front/Back)
ReadingMode 2(Single/Continuous)
Maximumand
MinimumFunctions Yes
CalculationFunctions Addition,Subtraction,Area,Volume,
SumofLengths,2pointindirect
(pythagoras),3pointindirect
InternalMemory Yes(upto20readings)
ResponseTime 2secs.
AutoShut-off Yes(after3mins)
LowBatteryIndicator Yes
PowerSupply 2“AAA”batteries
BatteryLife Upto4,000measurements
LaserClass ClassII
ProductCertications CE,RoHS,IP54
OperatingTemperature 14to122°F(-10to50°C)
StorageTemperature -4to140°F(-20to60°C)
OperatingHumidityRange <95%RH
Dimensions 4.5x1.9x1.1”(110x46x28mm)
Weight 3.5oz(100g)
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
5
INSTRUMENTS
INSTRUMENTS
Instrument Description
1. On/Measurebutton
2. Area/Volumebutton
3. IndirectMeasurementbutton
4. Single/ContinuousDistance
Measurementfunction
5. Plus(+)button
6. Minus(-)button
7. Storagebutton
8. Referencebutton
9. Backlight/Unitbutton
10.Clear/Offbutton
Display Description
1. Laserisactive
2. Referencelevel(front)
3. Referencelevel(rear)
4. Measurementindicator
Areameasurement
Volumemeasurement
Indirectmeasurement
Indirect(second)measurement
5. Singledistancemeasurement
6. Battery status
7. Memoryhistory,callupvalues
8. Instrumenterrorwarning
9. Continuous/Max&Minmeasurement
10.Primarydisplay
11.Secondarydisplay
12.Previousresult
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
6
INSTRUMENTS
INSTRUMENTS
Operating Instructions
Measuring Range
Themeasuringrangeislimitedto328’(100m).Ifmeasuringatnightor
duskandthetargetisinadarkarea,themeasuringrangewillincrease.To
increasethemeasurementrangeduringdaylightorifthetargethaspoor
reection properties you can use a target plate.
Target Surfaces
Measuringerrorscanoccurwhentakingmeasurementsofcolorless
liquids(e.g.water)ordustfreeglass,styrofoamorsimilarsemi-permeable
surfaces.Aimingathighglosssurfacesmaydeectthelaserbeamand
leadtomeasurementerrors.Whenmeasuringagainstnon-reectiveand
darksurfacesthemeasuringtimemayincrease.
On and Off
TheOn/Measurebuttonturnstheinstrumentandlaseron.Pressthe
CLEARbuttonforafewsecondstoturntheinstrumentandlaseroff.The
instrumentswitchesoffautomaticallyafterthreeminutesofinactivity.
Clear Button
Thisbuttoncancelsthelastactionandclearsthedisplay.
Reference Level Setting
Thedefaultreferencesettingisfrom
therearoftheinstrument.Pressthe
REFERENCEbuttontotakethe
selectionfromthetopofthe
instrument.Aspecialbeepsounds
wheneverthereferencesettingis
changed.Afterre-startingthe
instrumentthereferencereturns
automaticallytothedefaultsetting.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
7
INSTRUMENTS
INSTRUMENTS
Backlight
PresstheBACKLIGHT/UNITbuttontoturnthebacklightonandoff.
Distance Unit Setting
HolddowntheBACKLIGHT/UNITbuttonforafewsecondstochange
theunitofmeasure.Continuetopressthebuttontotogglebetweenall
unitsofmeasure.Youcanchoosebetweenm,ft,in.
Single Distance Measurement
PresstheON/MEASUREbuttontoactivatethelaser.Pressthebutton
againtotriggerthedistancemeasurement.Themeasuredvaluewillbe
displayedimmediately.
Continuous (Tracking)/Max & Min Measurement
Thecontinuousmeasurement
function(tracking)isusedforthe
transferring of measurements.
Incontinuousmeasurementmode,
themetercanbemovedtothetarget,
wherebythemeasuredvalueis
updatedapprox.every0.5seconds.
Thecorrespondingmaxandmin
valuesaredisplayeddynamicallyin
therstandsecondline.
Forexample,theusercanmove
fromawalltotherequireddistance,
whiletheactualdistancecanbe
readcontinuously.Forcontinuous
measurement,presstheMAX/MIN
buttonuntiltheindicatorfor
continuous measurements appears
onthedisplay.PressitagainorpresstheON/MEASUREbuttontostop
thefunction.Themeterresumesnormaloperationafter100
continuous measurements.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
8
INSTRUMENTS
INSTRUMENTS
Addition/Subtraction
PressthePLUSbuttontoaddthecurrentmeasurementtotheprevious
measurement.PresstheON/MEASUREbuttontoaddthesecond
measuredvalue;theresultwillautomaticallydisplay.
PresstheMINUSbuttontosubtractthecurrentmeasurementfromthe
previousmeasurement.PresstheON/MEASUREbuttonfortheresult
tobeshowninthesummarylineandthepreviousmeasurementwillbe
showninthesecondline.PresstheCLEARbuttonforthelaststepto
becancelled.PresstheMAX/MINbuttontoreturntosingledistance
measurementmode.
Area Measurement
PresstheAREA/VOLUMEbuttononcetoenterAreaMeasurementmode.
The iconwillappearonthedisplaytoconrmyouareinthecorrect
mode.PresstheON/MEASUREbuttontotaketherstmeasurement
(ie:length),presstheON/MEASUREbuttonagaintotakethesecond
measurement(ie:width).Thenthearea/surfaceisautomatically
calculatedanddisplayedinthesummarylineonthedisplay.Theprevious
measurementwillbeshowninthesecondline.
Volume Measurement
PresstheAREA/VOLUMEbuttontwicetoenterAreaMeasurement
mode.The iconwillappearonthedisplaytoconrmyouarein
thecorrectmode.PresstheON/MEASUREbuttontotaketherst
measurement(length),presstheON/MEASUREbuttonagaintotakethe
secondmeasurement(width),presstheON/MEASUREbuttonagainto
takethethirdmeasurement(height).Thenthevolumeisautomatically
calculatedanddisplayedinthesummarylineonthedisplay.Theprevious
measurementwillnotbeshown.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
9
INSTRUMENTS
INSTRUMENTS
Indirect Measurement
Thisisusedtodetermineadistance
usingtwoauxiliarymeasurements.
PresstheINDIRECT MEASUREMENT
buttononce,the iconwillappear
onthedisplay.
Aimatthehighestpointandpress
theON/MEASUREbuttontotakethe
measurement.Holdingtheinstrument
ashorizontalaspossiblepressandholdtheON/MEASUREbuttonto
triggercontinuousmeasurement,thehorizontallineismeasuredand
showninthesummaryandsecondarylines.
Three Point Measurement
PresstheINDIRECT MEASUREMENT
buttontwice,the iconwillappear
onthedisplay.Aimatthehighest
point(1)andpresstheON/MEASURE
buttontotriggerthemeasurement.
Holdingtheinstrumentashorizontal
aspossiblepressandholdthe
ON/MEASUREbuttontotrigger
continuousmeasurementandsweep
thelaserupanddownovertheideal
targetpoint(2),pressthe
ON/MEASUREbuttonagainto
conrmthevalue.Aimatthelower
point(3)andpresstheON/MEASURE
buttontotriggerthemeasurement.
Theresultsareshowninthesummary
andsecondarylinesatthesametime.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
10
INSTRUMENTS
INSTRUMENTS
Measurement Storage
Code Cause Corrective Measure
204 Calculationerror Repeatprocedure
208 Receivedsignaltooweak/measurement
timetoolong/Distance>50m Usetargetplate
209 Receivedsignaltoostrong Targettooreective(usetargetplate)
252 Temperaturetoohigh Cooldowninstrument
253 Temperaturetoolow Warm up instrument
255 Hardwareerror Switchmeteron/offseveraltimes*
PresstheStoragebuttontoviewtheprevious20records(measurements
orcalculatedresults).Usethe+and–buttonstonavigatetherecords.
Troubleshooting
*IferrorpersistscontactREEDInstrumentsat[email protected]
Care
Donotimmersetheinstrumentinwater.Wipeoffdirtwithadamp,soft
cloth.Donotuseaggressivecleaningagentsorsolutions.Handlethe
instrumentasyouwouldatelescopeorcamera.
Battery Replacement
Thisinstrumentuses2“AAA”alkalinebatteries.Thebatteriesneedto
bereplacedwhenthebatterysymbolashesonthedisplay.Removethe
batteriesbeforeanylongperiodofnon-usetoavoidthepossibilityof
corrosion.Onlyusealkalinebatteries.
1. Removebatterycompartmentcover.
2. Insertnewbatteries,respectingthecorrectpolarity.
3. Closethebatterycompartmentcover.
www.GlobalTestSupply.com