8
Operation in Manual Mode
•
Press and hold for 3 seconds to turn on Manual Mode when the instrument is
in Auto Mode or TILT Mode.
Green LED is solid green, and Red LED is solid red.
•
The Auto-leveling function is off, the instrument can place at any less
than 50°angle.
•
Press and hold for 3 seconds in Manual Mode to turn off Manual Mode, the
instrument will back to Auto-leveling Mode.
Speed Switch/Spot Mode
•
After Powered on and Auto-leveling or in Manual Mode (Not in SLOPE function),
the default speed is 300rpm:
(1) Short press to switch speed, followed by looping from
300rpm->600rpm->0rpm->150rpm ->300rpm;
(2) Short press to switch speed, followed by looping from
300rpm->150rpm->0rpm->600rpm->300rpm.
•
At 0rpm or Scan Mode(Not in SLOPE function):
(1) Press the laser dot will anticlockwise motion;
(2) Press the laser dot will clockwise motion;
At 0rpm:
(1) Short press / the rotation angle of laser dot is 10°.
(2) Long press / the laser dot will rotate at 0.5-1rpm.
(3) Press and hold / >4 seconds, the laser will blinking
3 times to remind the laser start to speed up, after that the laser
will rotate at 7.5-10rpm.
(4) Release / the laser dot will back to 0rpm.
•
In Scan Mode:
(1) Short press / the scan angle will rotate 6°, the scan function is kept.
(2) Long press / the scan will be stopped, the laser dot willrotate at
0.5-1rpm.
(3) Press and hold / >4 seconds, the laser will blinking 3 times to remind
the laser start to speed up, after that the laser will rotate at 7.5-10rpm.
(4) Release / it will back to scan function.
Remark:
When the rotation speed is switched from 300rpm to 0rpm for 0.5 seconds,
the output power of instrument will be low power, switched from 0rpm to scan
function or rotation for 1 second, it will be high power.