oventrop OV-DMC 2 User manual

Valves, controls + systems
Operating instructions
Flow meter
“OV-DMC 2”

2
Subject to modification without notice. Oventrop does not accept liability for the accuracy
of the OV-DMC flow meter readings.

3
Contents
Page
Content . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Characteristic lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Content of measuring case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Component connection diagram/Battery case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Keyboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Main menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
System-Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Measurement-Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Valve-Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Temperature measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Temperature input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Balanced pressure method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Data Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Kv-value-method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Computer-method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Permanent measurement of “Cocon”/“Cocon 4” valves and metering stations . . . . . . . . . . . . . . . . . . . . . . .19
Permanent measurement of differential pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
OV-Balance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Storage and printing of valve data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
xample . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Locking Keyboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Functional messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
rror messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

4
General information
General information:
The flow meter “OV-DMC 2” was specially designed for flow measurements and the hydronic balancing of
heating and cooling systems. In practice, operation off the line is guaranteed by using rechargeable batte ries.
To facilitate handling, null balance is automated. This process of changeover to the measuring position of the
measuring head is taken over by an electric motor which is automatically triggered by the flow meter during
each measurement. This step largely protects the measuring head against any damage. To protect the mea-
suring head from contamination, the inlet and outlet nipple are provided with integrated strainer inserts. Nip-
ples for replacement are supplied with each flow-meter (see part 17, page 7) and can be replaced by using a
standard spanner (spanner size 17 mm). Spare part number of the nipples for subsequent ordering:
106 91 86.
Attention: Before the measuring hoses are connected to the double regulating and
commissioning valve, the flow meter has to be connected to the measuring head and
has to be switched on.
Provide for free water flow through measuring hoses. Clean or replace strainer inserts
of the measuring hose in case of heavy pollution.
For further details regarding function sequences see page 12 and onwards.
The logical structure and the consequent query on the display offer a good condition to carry out hydronic
balancing of existing installations without calculation. Presetting of a double regulating and commissioning
valve can be calculated by using the balanced pressure method, computer method or OV balance method
after having entered the valve size and the nominal flow rate. The presetting values of individual double regu-
lating and commissioning valves can be calculated on the basis of the characteristic lines of all Oventrop
double regulating and commissioning valves as well as those of some competitors which are stored in the
flow meter (see list on next page).
When using the “OV-DMC 2” for the regulation of valves which are not produced by Oventrop, the corres -
ponding kv-value has to be entered before the first measurement. To do so, the kv-value method is chosen in
the menu "Measurement-Setup”. Any data obtained during measurement is stored in the “OV-DMC 2” and
can be processed via a PC under Windows which guarantees the filing of any data obtained during hydronic
balancing. Moreover, temperature can be measured by using the flow meter. To do so, the sensor is
introduced into the pressure test points at the double regulating and commissioning valve “Hydrocontrol”. As
for the double regulating and commissioning valves “Hycocon”, the temperature must be seized at the pipe-
work or the valve body.

5
Characteristic lines
Characteristic lines:
Characteristic lines of the Oventrop valves:
Indicated display
Double regulating and commissioning valves “Hycocon V, VTZ, VPZ” DN 15 to DN 40 Hycocon V
Regulating valves “Hycocon T, TZ” DN 15 to DN 25 Hycocon T
Regulating valves “Hycocon TM, HTZ” DN 15 to DN 40 Hycocon TM
Regulating valves “Hycocon TM, HTZ, ” Bronze kvs 5.0 DN 20 Hyco.TM RG
Regulating valves “Aquastrom C” DN 15 to DN 32 AquastromC
Double regulating and commissioning valves “Hydrocontrol R, VTR, VPR” DN 10 to DN 65 Hydroc. R
Double regulating and commissioning valves “Hydrocontrol G, VGC” DN 65 to DN 300 Hydroc. G
Double regulating and commissioning valves “Hydrocontrol F, VFC” DN 20 to DN 400 Hydroc. F
Double regulating and commissioning valves “Hydrocontrol FR, VFR” DN 50 to DN 200 Hydroc. FR
Double regulating and commissioning valves “Hydrocontrol FS, VFN” DN 65 to DN 300 Hydroc. FS
Double regulating and commissioning valves “G-86” DN 10 to DN 65 (Swedish market) G- 86
Double regulating and commissioning valves “RF-93” DN 20 to DN 300 (Swedish market) RF- 93
Regulating valve for chilled ceiling installations “Cocon 2TZ” kvs 0.45 DN 15 Coconkv045
Regulating valve for chilled ceiling installations “Cocon 2TZ” kvs 1.0 DN 15 Coconkv1.0
Regulating valve for chilled ceiling installations “Cocon 2TZ” kvs 1.8 DN 15 Coconkv1.8
Regulating valve for chilled ceiling installations “Cocon 2TZ” kvs 4.5 DN 20 Coconkv4.5
Four-port regulating valve “Cocon 4 TZ ” kvs 0.45 DN 15 Cocon4-045
Four-port regulating valve “Cocon 4TZ” kvs 1.0 DN 15 Cocon4-1.0
Four-port regulating valve “Cocon 4 TZ” kvs 1.8 DN 15 Cocon4-1.8
Brass metering station LF kvs 0.55 DN 15 met.st.LF
Brass metering station MF kvs 1.2 DN 15 met.st.MF
Brass metering station DN 15 to DN 50 /
Flanged stainless steel metering station DN 65 to DN 900 met.st.
Flanged cast iron metering station DN 65 to DN 300 met.st.CI
Characteristic lines of other valves:
Tour & Andersson (stored values taken from the catalogue 1999)
Flanged valve type “STAF” DN 20 to DN 300 STAF
Flanged valve type “STAF-SG” DN 20 to DN 300 STAF-SG
Flanged valve type “STAF-R” DN 65 to DN 150 STAF-R
Groove end valve type “STAG” DN 65 to DN 300 STAG
Female threaded valve type “STA” DN 15 to DN 50 STA
Female threaded valve type “STAD” DN 10 to DN 50 STAD
Male threaded valve type “STADA” DN 10 to DN 50 STADA
Female threaded valve type “STA-DR” DN 15 to DN 25 STA-DR
Crane (stored values taken from the catalogue 2000):
Double regulating and commissioning valves:
Fig.-No. D 930: DN 10 to DN 50 D930
Fig.-No. DM 930: DN 20 to DN 300 DM930
Metering stations/combinations metering stations/valves:
Fig.-No. D 901/D 941/D 931: DN 15 to DN 50
D901/D941/D931
Fig.-No. D 902/D 942: DN 15 D902/D942
Fig.-No. D 932: DN 15 D932
Fig.-No. D 933: DN 15 D933
Fig.-No. D 934: DN 15 D934
Fig.-No. DM 900/DM 940: DN 20 to DN 300 DM900/DM940
Fig.-No. DM 950: DN 50 to DN 300 DM950

6
Characteristic lines
Hattersley (stored values taken from the catalogue 2000):
Double regulating and commissioning valves:
Fig.-No. M737: DN 50 to DN 300 M737
Fig.-No. 1700: DN 15 to DN 50 1700
Fig.-No. 1700L: DN 15 1700L
Fig.-No. 1710: DN 15 to DN 50 1710
Metering stations/combinations metering stations/valves:
Fig.-No. M2733: DN 50 to DN 300 M2733
Fig.-No. M2943G: DN 350 to DN 600 M2943G
Fig.-No. M2944G: DN 350 to DN 600 M2944G
Fig.-No. M2963G: DN 350 to DN 600 M2963G
Fig.-No. M2964G: DN 350 to DN 600 M2964G
Fig.-No. M2973G: DN 350 to DN 600 M2973G
Fig.-No. M2974G: DN 350 to DN 600 M2974G
Fig.-No. 2473LC: DN 15 2473LC
Fig.-No. 2473L: DN 15 2473L
Fig.-No. 2473MC: DN 15 2473MC
Fig.-No. 2473M: DN 15 2432M
Fig.-No. 2432C: DN 15 2432C
Fig.-No. 2432: DN 15 to DN 50 2432
Fig.-No. 5200: DN 15 to DN 50 5200
Fig.-No. M7733CSDR: DN 65 to DN 200 M7733CSDR

7
Content of measuring case
11. Measuring case
12. Flow meter “OV-DMC 2” with shoulder strap
13. Measuring head with connection cable, connection nipple for measuring hose and two rubber rings
protecting the measuring head against impact
14. Power pack with connecting cable
15. Temperature sensor with connecting cable 1 m long
16. Measuring hose, red with quick couplings 0.5 m long
17. Measuring hose, blue with quick couplings 0.5 m long
18. Allen key 3 mm with black handle
19. Allen key 4 mm with black handle
10. Allen key 8 mm with black handle
11. PC connection cable to transmit stored data of the “OV-DMC 2” to the USB interface
12. USB-Stick for data transmission
13. 2 measuring adapters with connection thread R 3⁄4for quick-coupling technic
Suitable for “Hydrocontrol” as well and the fill and drain tool 106 17 91 of “Hycocon”
14. Measuring adapter with connection thread R 3⁄4for double regulating and commissioning valves
“Hydrocontrol” with needle technic
15. Set of measuring needles 106 91 99 for measuring technic “classic” of double regulating and
commissioning valves, e.g.“Hydrocontrol”
16. Operating key 106 01 85 for older double regulating and commissioning valves “Hydrocontrol”
17. Two connection nipples 106 91 86 for replacement at measuring head
18. Set of measuring needles 106 17 99 for measuring technic “eco” of double regulating and commissioning
valves, e.g.“Hycocon”
19. 2 fill and drain tools 106 17 91 for measuring technic “eco” of double regulating and commissioning
valves, e.g.“Hycocon”
20. Measuring device 114 50 99 for regulating valves “Cocon” with measuring technic “eco”
Operating instructions

8
12. Flow meter “OV-DMC 2” with shoulder strap
13. Measuring head with connection cable, connection nipples for measuring hoses and two rubber rings protecting
the measuring head against impact
14. Power pack with connecting cable
15. Temperature sensor with connecting cable 1.0 m long
11. PC connecting cable to transmit stored data of the “OV-DMC 2” to the USB interface

9
Component connection diagram/Battery case
Lockable plug
red
positioning
point
Sliding sleeve
Guide
Lockable plug-in connection between
flow meter and measuring head:
The plug is released by pushing back
the sliding sleeve!
The red positioning point indicates the
position of the guide when introducing
the plug into the guiding groove of the
jack bush on the lower side of the flow
meter.

10
Technical data
Measuring range: Measuring range - differential pressure: -0.05 kPa to 200 kPa
Max. static excess pressure: 2000 kPa
Measuring range – temperature: -20°C to +120°C
Resolution: Differential pressure: 0.01 kPa
Flow: 0.0001 l/s
Temperature: 0.1°C
Accuracy: Differential pressure: up to 10 kPa ± 0.1 kPa
10 to 200 kPa 1% of measured value
Flow: 0.01 l/s
Temperature ± 1°C
Ambient temperature: Working temperature: 0°C to 40°C
Storage: -20°C to +60°C
Attention: In case of risk of frost, no water may remain in the
measuring head!
In this case, the measuring head and the measuring hoses have to
be drained completely.
Humidity: Max. relative humidity of 90% non-condensing
Protection class: Body IP52
Keyboard IP54
Dimensions/weight: Flow meter: 160 x 63 x 40 mm, weight 470 g
Measuring head: 130 x 70 x 70 mm, weight 1240 g
Display: LCD display with backlighting
Power supply: 4 rechargeable NiMh batteries
or by using enclosed power pack 230 V AC 50/60 Hz
or by using 4 commercial Mignon batteries 1.5 V
Attention: In case of battery operation, the power pack must not be
connected!
Interface: USB
This manual suits for next models
1