1 SPECIFICATION................................................................................................................................2
2 TECHNICAL SPECIFICATION:......................................................................................................2
3 INTRODUCTION................................................................................................................................3
3.1 POWER BUTTON............................................................................................................................... 3
3.2 AIMING BUTTON.............................................................................................................................. 3
3.3 SCAN BUTTON..................................................................................................................................4
3.4 MAIN SCREEN................................................................................................................................. 4
3.5 POWER/USB PORT...........................................................................................................................4
3.6 PC PORT..........................................................................................................................................4
3.7 FOV LENS....................................................................................................................................... 4
3.8 LASER AIM AT................................................................................................................................. 4
3.9 CAMERA.......................................................................................................................................... 4
4 OPERATION MANUAL.................................................................................................................... 4
4.1 POWER ON/OFF............................................................................................................................... 4
4.2 MAIN INTERFACE.............................................................................................................................5
4.3 SETTING...........................................................................................................................................6
4.3.1 Configuration...........................................................................................................................7
4.3.2 Parameters correction.............................................................................................................. 7
4.4 SCAN DATA......................................................................................................................................8
4.4.1 Scan spectral intensity............................................................................................................. 8
4.4.2 Scan Reflectance................................................................................................................... 10
4.4.3 Scan irradiance...................................................................................................................... 13
4.4.4 Scan absorbance.................................................................................................................... 15
4.5 HISTORICAL RECORDS...................................................................................................................18
4.5.1 Review historical records...................................................................................................... 18
4.5.2 Rename historical records..................................................................................................... 19
4.5.3 Export data............................................................................................................................ 19
4.5.4 Delete data.............................................................................................................................21
5 USER MANAGEMENT................................................................................................................... 22
5.1 ADD USERS....................................................................................................................................22
5.2 REVISE &DELETE USERS...............................................................................................................23
6 SYSTEM INFORMATION...............................................................................................................25
7 NOTES................................................................................................................................................ 25
8 ATTACHMENT.................................................................................................................................26

ATP9100 Handheld Field Spectroradiometer User Manual
2
1 Specification
Optosky ATP9100 is a new handheld hyperspectral field spectroradiometer that
employs spectral range between 300-1100nm, and it's applied to fields of remote
sensing measurement, crop monitoring, research of forest and oceanography etc.
ATP9100 field spectroradiometer employs high performance, fast and accurate
measurement, easy to operate and held etc. It's configured powerful software package,
and applied to measurement of reflectance, radiometry, photometry and colorimetry.
2 Technical Specification:
SN
Specification
1
Field Spectroradiometer
Detector:2048pixels CCD;
Linearity:> 99%;
Spectral range:300-1100 nm;
Spectral resolution:<2.5nm@546nm;
Wavelength accuracy:± 0.5 nm;
Repeatability:± 0.3 nm @ ± 10 °C;
SNR:>800
Spectral sampling interval:0.6 nm;
Hardware spectral average: Max reach up to 100,000 times;
Size: 151×157×85mm;
Weight: 1.1Kg
Temp./Humidity:
0°C~40°C (working temp.)
-15°C~55°C (storage temp.)
Dry to non-condensate status
Probe tip angle accuracy: <1°(0°~30°)。
IP65
2
Standard Probe,SMA905, 6-pins water proof data port, M12×0.5 screw hole used to
connect fiber, cable and focus lens. Compact size.
Built-in inclined angle sensor can display probe inclined angle in the software
Built-in laser on used to indicate probe detect orientation
Replaceable FOV lens, available in 1°/8°/15°/25°, and optional angles.

ATP9100 Handheld Field Spectroradiometer User Manual
3
Scan button
Main screen
Aiming button
Power button
Handle
Power/USB Port
PC port
FOV lens
Laser aim at
Camera
3 Introduction
3.1 Power button
Long press power button till screen lighting up can start the device. Built-in
Li-battery can be charged with adaptor.
*Remark: It’s required the company's equipped batteries to be used, and a
certified adapter or connector could be used to charge the instrument, otherwise, it
can danger human body or the device.
3.2 Aiming button
Press aiming button can aim at the scan area before detection.

ATP9100 Handheld Field Spectroradiometer User Manual
4
*Remark: It prohibits to aim at eyes or skin while laser on.
3.3 Scan button
Users can press scan button to scan spectral data, one time press can save the last
scan data, but long press can save continuous scan spectral data.
3.4 Main Screen
5-Inch HD touch screen 720×1080, brief interface, easy-to-operate.
3.5 Power/USB port
Power/USB port is in the right side near the screen, the port can be used to
charge electricity, and connect USB cable to transmit data.
3.6 PC Port
Users connect PC port to PC software to realize data measurement on PC.
3.7 FOV lens
User can select different FOV lens according to FOV scope.
3.8 Laser aim at
The device employs a function of laser aiming paralleled to lens, and users can
adjust the head orientation to the reasonable scope and aim at the objective.
3.9 Camera
Built-in 12-mega camera can take a picture of the sample detected.
4 Operation manual
4.1 Power On/Off
Power on: Long press power button to access to login interface refer to Fig 4.4.4

ATP9100 Handheld Field Spectroradiometer User Manual
5
Fig 4.1.1 User login interface
First login user account and password are available in:
User account: supportAdmin; PSW: 123456
Remind: It’s suggest to revise password after login in order to ensure data safety.
Login:Select user name, input password, click login to access to main interface.
Power off: Long press power button till screen popup up power off warning refer to
Fig4.1.2, click button to power off.
Fig 4.1.2 Power off warning
4.2 Main interface
Login to access to main interface refer to Fig4.2.1

ATP9100 Handheld Field Spectroradiometer User Manual
6
Fig 4.2.1 Software main interface
【Setup】:Click it to access to configuration setting.
【Measure Types 】:Four types are available for selection including
absorbance, irradiance, reflectance, and spectral intensity.
【Historical Records 】 : Click historical records can review, export and
delete historical records.
【User Management】:click user management to create account, revise
password.
【System Info 】 : Include product name, model, s/n software version,
company information etc.
【Dark Current】:Click to scan dark current
【Reference Spectrum】:Click to scan reference spectrum
【Scan Data】:Click to scan spectral data
4.3 Setting
Setup parameters of scan times, integration time, parameters correction (angles
correction), and measure absorbance, irradiance, reflectance, and spectral intensity
refer to Fig4.3.1 and Fig4.3.2
Fig 4.3.1 Setting interface 1

ATP9100 Handheld Field Spectroradiometer User Manual
7
Fig 4.3.2 Setting and select measure items
4.3.1 Configuration
【Scan Times】:System can get average base on scan times.
【Integration Time】:Set time to scan spectrum of the sample.
*Remark :Scan times and integration time are not fixed value, it’s needed to
confirm base on light intensity and user requirement, sometimes it takes many times
to try out suitable integration time to set.
4.3.2 Parameters correction
【Angles correction】:Position the device in vertical to horizontal level, click angles
correction refer to warning in Fig 4.3.2.1, click confirm can set angle to zero,
click cancel correction.
Fig 4.3.2.1 Angles correction warning

ATP9100 Handheld Field Spectroradiometer User Manual
8
4.4 Scan data
4.4.1 Scan spectral intensity
Click【▲】, select spectral intensity refer to Fig 4.4.1.1, and setup scan times
and integration time, click save. System warn of click to save parameters or not
refer to Fig 4.4.1.2, click confirm to save parameters.
Fig 4.4.1.1 Click test type-spectral intensity
Fig 4.4.1.2 Setup and save parameters
Disassemble FOV lens, use cap to cover interface between fiber and lens
refer to Fig 4.4.1.3, click dark current refer to system warning info in Fig 4.4.1.4
Click confirm scan dark current, complete dark current acquisition, then dark
current can be saved in the device, if the user do not scan dark current again, it
can use the last dark current value refer to 4.4.1.5.

ATP9100 Handheld Field Spectroradiometer User Manual
9
Fig 4.4.1.3 Cap cover fiber interface
Fig 4.4.1.4 Warning of dark current acquisition
Fig 4.4.1.5 Complete dark current acquisition
Click scan data on screen or press scan button at the side, system can
continuously scan data, click save data refer to Fig 4.4.1.6, input file name and
click confirm can save the last piece of data, click cancel the save.