Omega I.Server MicroServer I.THX-M User manual

User’s Guide
omega.com
e-mail: [email protected]
For Latest Product Manuals
omegamanual.info
®
®
Shop on line at
Temperature + Humidity

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply.
OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark
to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any
errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient-connected applications.
This device is marked with the international caution symbol. It is important to read the Setup Guide before installing or
commissioning this device as the guide contains important information relating to safety and EMC.

TABLE OF CONTENTS
Part 1: Introduction
1.1 Safety and MC Considerations ...........................................................2
1.2 Before You Begin ...................................................................................2
1.3 Description..............................................................................................2
Part 2: Hardware
2.1 Dimensioins ...........................................................................................4
2.2 Wall Mounting ........................................................................................5
2.3 DIP Switches...........................................................................................5
2.4 Parts of iServer Unit ..............................................................................6
2.5 Disassembly Instruction .......................................................................7
2.6 Network Communication Interfaces ....................................................8
2.6.1 10Base-T RJ-45 Pinout .............................................................8
2.6.2 10Base-T Crossover Wiring .....................................................8
2.7 Relay Wiring Connections ....................................................................8
2.8 Running on Battery Power ...................................................................8
2.9 Flash Memory Format ............................................................................9
Part 3: Network Configuration
3.1 Network Protocols ...............................................................................10
3.2 thernet (MAC) Address .....................................................................10
3.3 DHCP .................................................................................................11
3.4 DNS .................................................................................................11
3.5 IP Address ............................................................................................11
3.5.1 Default IP Address ..................................................................12
3.6 Port Number..........................................................................................12
Part 4: Operations
4.0 Testing the Connection .......................................................................13
4.1 iConnect Software................................................................................14
4.2 Setting a new IP Address over the Network .....................................16
4.3 Setup and Operation using the iServer Web Page ...........................17
4.3.1 Read Sensor ............................................................................17
4.3.1.1 Java Runtime nvironment 1.4 Setup Instructions .18
4.3.1.2 Java Runtime 1.5 (5.0) Setup Instructions ................19
4.3.1.3 Browser Proxy Selection ............................................19
4.3.2 Adjustable Chart......................................................................20
4.3.3 Retrieving Data from Flash.....................................................21
4.3.4 Access Control .......................................................................22
4.3.5 Configuration...........................................................................23
4.3.5.1 Configuration - Recording Initializing ...................................29
4.3.5.2 Configuration - Recording Active ..........................................30
4.3.5.3 Configuration - General Notes ...............................................31
4.3.6 Sensor Parameter....................................................................32
4.4 Telnet Setup .........................................................................................33
4.5 HTTPget Program.................................................................................33
4.5.1 HTTPget using Port 1000........................................................34
4.5.2 HTTPget and ARP to setup Device IP Address ...................35
4.6 ARP Protocol ........................................................................................36
4.7 iLog Software........................................................................................37
4.8 Mail Notifier Software...........................................................................38
4.8.1 Installation ...............................................................................38
4.8.2 Program Options Setup and Configuration .........................39
i

4.8.3 Device Setting Setup and Configuration...............................40
Part 5: Specifications .................................................................................................41
Part 6: Factory Preset Values ......................................................................................42
Appendix A Glossary ................................................................................................43
Appendix B IP Address ............................................................................................44
Appendix C IP Netmask ............................................................................................45
Appendix D ASCII Chart ..........................................................................................46
ASCII Chart Control Codes .................................................................47
Appendix iLog rror Messages............................................................................48
Part 7: Approvals Information
7.1 lectromagnetic Compatibility ( MC) ...............................................49
7.2 FCC ..................................................................................................49
7.3 Certificate of Conformance .................................................................49
LIST OF FIGU ES & TABLES:
Figure 1.1 iServer and iLD Big Display on the thernet Network........................3
Figure 2.1 Dimensions ............................................................................................4
Figure 2.2 Wall Mounting ........................................................................................5
Figure 2.3 DIP Switches...........................................................................................5
Figure 2.4 Parts of iServer Unit...............................................................................6
Figure 2.5 Opening the Unit ....................................................................................7
Figure 2.6 RJ45 Pinout ............................................................................................8
Figure 2.7 10Base-T Crossover Cable Wiring .......................................................8
Figure 2.8 Relay Connections ................................................................................8
Figure 2.9 Chart of Simulated Data ........................................................................9
Figure 3.1 Labeling ................................................................................................10
Figure 3.2 DIP Switch on Bottom Side of iServer................................................11
Figure 3.3 Telnet Login into the iServer...............................................................12
Figure 4.1 Pinging the iServer from MS-DOS Prompt ........................................13
Figure 4.2 Assigning an IP Address using iConnect .........................................14
Figure 4.3 Accessing the iServer’s Home Page Menu........................................15
Figure 4.4 Access Control ...................................................................................16
Figure 4.5 iServer Home Page ..............................................................................17
Figure 4.6 Login and Administration Password .................................................17
Figure 4.7 Read Sensor .........................................................................................18
Figure 4.8 Adjustable Chart...................................................................................20
Figure 4.9 iFlash Download Utility........................................................................21
Figure 4.10 Access Control ....................................................................................22
Figure 4.11 Configuration (Recording Not Active) ...............................................24
Figure 4.12 Configuration - Recording Settings ...................................................28
Figure 4.13 Configuration (Recording Initializing) ...............................................29
Figure 4.14 Configuration (Recording Active).......................................................30
Figure 4.15 Sensor Parameter ................................................................................32
Figure 4.16 Remote nd Char .................................................................................32
Figure 4.17 ARP Commands and Responses .......................................................36
Figure 4.18 iLog Software Logging Data................................................................37
Figure 4.19 iServer Mail Notifier Main Window......................................................38
Figure 4.20 iServer Mail Notifier Profile Setup ......................................................39
Figure 4.21 iServer Mail Notifier Device Setting ...................................................40
Table 2.1 Parts of iServer Unit.............................................................................5
ii

NOTES, WA NINGS and CAUTIONS
Information that is especially important to note is identified by the following labels:
• NOT
• WARNING or CAUTION
• IMPORTANT
• TIP
NOT : Provides you with information that is important to successfully
setup and use the iServer.
CAUTION: Tells you about the risk of electrical shock.
CAUTION: Risk of danger. Tells you of circumstances or practices
that can effect the instrument’s functionality and must refer to
accompanying documents.
TIP: Provides you helpful hints.
FEATU ES
• Temperature
• Relative Humidity
• Web Server
• Virtual Chart Recorder
• Two Relay Alarms
• Accurate Readings
• Password Protection
• mail Alarms
• Data Logging
• 2, 4 or 8M bytes Flash Memory Card
• Real-Time Clock
• LCD Display
• UPS / Stand-alone 9Vdc Battery
1

PA T 1
INT ODUCTION
1.1 Safety and MC Considerations
Refer to the CE Approvals Section.
MC Considerations
•Whenever EMC is an issue, always use shielded cables.
•Never run signal and power wires in the same conduit.
•Use twisted-pair wires for signal connections.
•Install Ferrite Bead(s) on signal wires close to the instrument if EMC problems persist.
Failure to follow all instructions and warnings may result in injury!
1.2 Before You Begin
Inspecting Your Shipment: Remove the packing slip and verify that you have received
everything listed. Inspect the container and equipment for signs of damage as soon as
you receive the shipment. Note any evidence of rough handling in transit. Immediately
report any damage to the shipping agent. The carrier will not honor damage claims
unless all shipping material is saved for inspection. After examining and removing the
contents, save the packing material and carton in the event reshipment is necessary.
Customer Service: If you need assistance, please contact the Customer Service
Department nearest you.
Manuals, Software: The latest Operation Manual as well as free configuration software
(iConnect), datalogging software (iLog), download utility (iFlash), and Mail Notifier are
available at the website listed on the cover page of this manual or on the CD-ROM
enclosed with your shipment.
1.3 Description
View Temperature + Humidity with a Web Browser. The iServer let’s you monitor and
record Temperature and Relative Humidity over an Ethernet network or the Internet with
no special software -- just a Web browser. The iServer serves Active Web Pages to
display real time readings and display charts of temperature and humidity, or log data in
standard data formats for use in a spreadsheet or data acquisition program such as
Excel or Visual Basic.
Adjustable Charts. The Java™ Applet chart scales are fully adjustable on the fly. For
example, the chart can display one day, one week, one month or one year. Temperature
and humidity can be charted across the full span (-40 to 124ºC, and 0 to 100% RH) or
within any narrow range (such as 20 to 30ºC).
Flash Memory. The iServer records data on a removable 2-MByte Flash Memory card
(included) that can store one full year of readings taken at one-minute intervals (or two
months of readings taken at ten second intervals).
Up to four years of temperature readings can be stored on the optional 8 MByte card.
Even if the Ethernet network fails, data will continuously record on the built-in nonvolatile
flash memory.
Installation and operation of the iServer requires no special training, tools, or software.
The device connects to any Ethernet network with standard cable and is powered by a
universal AC adapter which is supplied with the product.
2

Award-winning Technology. The iServer is simple to install and use. It features award
winning technology that requires no special software except a Web browser. The iServer
connects to an Ethernet Network with a standard RJ45 connector and sends data in
standard TCP/IP packets. It is easily configured with a simple menu using a Web browser
and can be password protected. From within an Ethernet LAN or over the Internet, the user
simply types its IP address or an easy to remember name such as "Cleanroom 5" or
"Server Room" in any Web Browser, and the iServer serves a Web Page with the current
readings. The iServer comes complete with one temperature/humidity wand probe, full
documentation and software.
Alarms and mail. The device can trigger an alarm if temperature goes above or below
a set point that you determine. Your alarm can be sent by email to a single user or to a
group distribution list, including text messages to cell phones and PDA’s.
A standard web browser can be used to monitor and chart temperature and humidity. The
browser can also be used to configure the device’s IP address, passwords for access
and all configuration parameters. An iLD Big Display can display temperature and
humidity received from an iServer over the Ethernet or the Internet.
The following example illustrates how you can hookup an iServer and iLD to your
network:
Figure 1.1 iServer and iLD Big Display on the thernet Network
COL
ON
TX
RX
COMPUTER with
Standard Web Browser
and
3

4
PA T 2 HA DWA E
2.1 Dimensions
Figure 2.1 Dimensions
2.42 [61.6]
3.2 [82]
3.56 [90.3] 3.5 [89]
10.7 [270]
1.44
[36.6]
TEMPERATURE/HUMIDITY
Dimensions are in
inches with
millimeters in [ ].
0.10
[2.54]
0.12 [3.0]
If unit is to be
mounted on a flat
surface, you may
take the bottom
rubber feet off the
unit.

5
2.2 Wall Mounting
Position unit where required. Mark and drill the two #4 screw holes.
After bracket is mounted on the wall, align back of unit over the three bracket clips, once
engaged, slide downward, the unit will snap in place.
Figure 2.2 Wall Mounting
It is recommended that you ground your unit by connecting a wire to the
Return/Ground position of the relay connector, see Figure 2.8.
2.3 DIP Switches
The iServer is shipped with all DIP
switches in "OFF" position.
DIP Switch Usage
1) N/C - not used
2) To change to default factory
settings
3) To enable/disable DHCP
4) N/C - not used
To set the iServer to factory default settings, slide DIP switch #2 to ON position.
Power the iServer on and wait about 10 seconds until the iServer fully boots up.
Set the DIP switch #2 back to OFF position (it does not matter if the iServer is
powered ON or OFF, just make sure that the DIP switch is set to OFF, otherwise,
every time the unit is power-cycled the factory settings will take over.
2.42 [61.6]
1.50 [38.1]0.46 [11.7]
1.31 [33.3]
REAR WIRE
ENTRY AREA
DRILL 0.125 [3.17]
USE TWO, #4
FLAT HEAD SCREWS
TO MOUNT BRACKET
BRACKET CLIPS (3)
SNAP
1
4
3
2
OFF
ON
1
4
3
2
OFF
ON
Figure 2.3 DIP Switches

6
2.4 Parts of the iServer Unit
Figure 2.4 Parts of the iServer Unit
Table 2.1 Parts of iServer Unit
TH RN T RJ45 interface for 10BASE-T connection.
R S T Button: Used for power reseting the iServer.
ACTIVITY LED (Red) Blinking: Indicates network activities (receiving or sending packets).
N T LINK LED (Green) Solid: Indicates good network link.
DIAGNOSTICS LED (Yellow) Blinking: Indicates transmitting data from iServer to flash memory
card. When DHCP enabled, it remains solid until DHCP IP address is received.
LED (Green) Blinking: Indicates receiving data by the iServer from flash memory.
°C/°F Button: Change display units of measurement from °C to °F
TIM Button: Change display from DATE and TIME to RH and TEMP
STBY Button: Will stop the Flash from recording.
BKLT Button: Display Back Light
When using the small push buttons, hold the button until “WAIT” is displayed on the LCD and
then release.
9-12 Vdc
ACTIVITY
NETWORK LINK
DIAGNOSTICS
AND STATUS
iServer Reset Button
iServer LEDs
iServer
RJ45 interface
dc Power Input
Probe
Handle
Clip
TEMPERATURE/HUMIDITY
C/ F STBYTIME BKLT
ETHERNET RESET
1
8
Flash
Memory
Card
Reset
Button
Flash
Memory
Card
16 Digit
LCD Display
Buttons
DB9
Connector
Side or Bottom
Wire Entry for
Relay Connector
Removable Plug
Connector for Relays
under the Cover
6
1
Table of contents
Other Omega Measuring Instrument manuals

Omega
Omega HHP350 Series User manual

Omega
Omega FPDM1000 User manual

Omega
Omega FMG600 Series User manual

Omega
Omega DP6060 User manual

Omega
Omega THDP-10 Series User manual

Omega
Omega PHB21 User manual

Omega
Omega DP41-B Series User manual

Omega
Omega DP18-RV1 User manual

Omega
Omega HHF143 User manual

Omega
Omega HHM598F User manual

Omega
Omega PHH-1X Litmustik User manual

Omega
Omega APH2 User manual

Omega
Omega DP18-AC1 User manual

Omega
Omega FPD-4000 Series User manual

Omega
Omega SP-005 User manual

Omega
Omega DP606A User manual

Omega
Omega SP-003 User manual

Omega
Omega PRESSURE GAUGES DPG3000 User manual

Omega
Omega FTB380 Series User manual

Omega
Omega CMDP Series User manual