MRC MS-7004SD User manual

SD card real time recorder
4 PINS
SOIL MOISTURE METER
Model : MS-7004SD
Your purchase of this
SOIL MOISTURE METER with
SD CARD DATA LOGGER
marks a step forward for you
into the field of
precision measurement.
Although this meter a
complex and delicate
instrument, its durable
structure will allow
many years of use if
proper operating
techniques are
developed. Please read
the following
instructions carefully
and always keep this
manual within easy
reach.
OPERATION MANUAL
Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 ,3
MRC. 1.23

TABLE OF CONTENTS
1. FEATURES..............................................................................
..................................................................
1
2. SPECIFICATIONS........................................................................................
..................................................
2
3. FRONT PANEL DESCRIPTION...................................................................................
.................................................
5
4. MEASURING PROCEDURE.....................................................................................
.................................................
6
4-1 Function selection/Measurement..................
..................................................................
6
4-2 Data Hold...........................................................................................................................................................
7
4-3 Data Record ( Max./ Min. reading )......................................................................................................................................
7
4-4 LCD Backlight ON/OFF......................................................................................................................................
7
5. DATALOGGER............................................................................................
......................................................
8
5-1 Preparation before execute datalogger function....................
..................................................................
8
5-2 Auto Datalogger ( Set sampling time ≧ 1 second )................
..................................................................
9
5-3 Manual Datalogger ( Set sampling time = 0 second )................
..................................................................
10
5-4 Check time information.............................................................
..................................................................
10
5-5 SD Card Data structure.......................................
..................................................................
11
6. Saving data from the SD card to the computer.......................
..................................................................
12
7. ADVANCED SETTING.............................................
..................................................................
13
7-1 Set clock time ( Year/Month/Date, Hour/Minute/ Second ).......
..................................................................
14
7-2 Set sampling time ...................................................
..................................................................
15
7-3 Auto power OFF management ....................
..................................................................
15
7-4 Set beep Sound ON/OFF...........................
..................................................................
15
7-5 Decimal point of SD card setting.........................
..................................................................
16
7-6 SD memory card format...............................
..................................................................
16
7-7 Select the temperature unit to ℃ or ℉ .................
..................................................................
17
8. POWER SUPPLY from DC ADAPTER...................
..................................................................
18
9. BATTERY REPLACEMENT...........................................................................................
....................................
18
10. SYSTEM RESET............................................................................................................
.......................................
19
11. RS232 PC serial interface.....................................................................................
..............................................................
19
12. PATENT...............................................
........................................................................................................
21

1. FEATURES
*Measurement ranges, 0 ~ 100 %. 0 ~ 60 ℃
* Four PIN probe
* High accuracy
* Fast response.
* Easy Installation.
* Separate probe, easy for operation of different environment
measurement .
* Thermister temperature.
* Real time SD memory card Datalogger, it Built-in Clock
and Calendar, real time data recorder , sampling time set
from 1 second to 3600 seconds.
* Manual datalogger is available ( set the sampling
time to 0 ), during execute the manual datalogger
function, it can set the different position ( location ) No.
( position 1 to position 99 ).
* Innovation and easy operation, computer is not
need to setup extra software, after execute
datalogger, just take away the SD card from the
meter and plug in the SD card into the computer,
it can down load the all the measured value with
the time information ( year/month/date/
hour/minute/second ) to the Excel directly, then
user can make the further data or graphic
analysis by themselves.
* SD card capacity : 1 GB to 16 GB.
* LCD with green light backlight, easy reading.
* Can default auto power off or manual power off.
* Data hold, record max. and min. reading.
* Microcomputer circuit, high accuracy.
* Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter.
* RS232/USB PC COMPUTER interface.
1

2. SPECIFICATIONS
2-1 General Specifications
Circuit Custom one-chip of microprocessor LSI
circuit.
Display LCD size : 52 mm x 30 mm
LCD with green backlight ( ON/OFF ).
Measurement Soil moisture : 0 ~ 100 %
Range. Thermister temperature : 0 ~ 60
℃
.
Datalogger Auto 1 second to 3600 seconds
Sampling Time @ Sampling time can set to 1 second,
Setting range but memory data may loss.
Manual Push the data logger button
once will save data one time.
@ Set the sampling time to
0 second.
@ Manual mode, can also select the
1 to 99 position ( Location ) no.
Memory Card SD memory card.
Advanced * Set clock time ( Year/Month/Date,
setting Hour/Minute/ Second )
* Set sampling time
* Auto power OFF management
* Set beep Sound ON/OFF
* Decimal point of SD card setting
* SD memory card Format
*Set temperature unit to ℃ or ℉
Temperature Automatic temp. compensation for the
Compensation NTC thermister.
2

Data Hold Freeze the display reading.
Memory Recall Maximum & Minimum value.
Sampling Time Approx. 1 second.
of Display
Data Output RS 232/USB PC computer interface.
* Connect the optional RS232 cable
UPCB-02 will get the RS232 plug.
* Connect the optional USB cable
USB-01 will get the USB plug.
Operating 0 to 50 ℃.
Temperature
Operating Less than 85% R.H.
Humidity
Power Supply *Alkaline or heavy duty DC 1.5 V battery
( UM3, AA ) x 6 PCs, or equivalent.
*DC 9V adapter input. ( AC/DC power
adapter is optional ).
Power Current Normal operation ( w/o SD card save
data and LCD Backlight is OFF) :
Approx. DC 46 mA.
When SD card save the data but and
LCD Backlight is OFF) :
Approx. DC 65 mA.
* AC/DC power adapter is optional.
consumption will increase approx.
16 mA.
Power off Auto shut off ( approx. 10 minutes) saves battery
life or manual off by push power button > 2 sec..
Weight 538 g/1.12 LB. ( without battery )
Dimension METER : 177 x 68 x 45 mm ( 7.0 x 2.7 x 1.9 inch)
PROBE : Ø 50 * 113 mm ( TEST PIN 78 mm )
Standard * Instruction manual.............................. 1 PC
Accessories * Moisture sensor with protective
Included ........................................... 1 PC
3

Optional SD Card
Accessories AC to DC 9V adapter.
USB cable, USB-01.
RS232 cable, UPCB-02.
Data Acquisition software,SW-U801-WIN.
Hard carrying case, CA-07A.
2-2 Electrical Specifications (23±5
℃
)
Soil Moisture
Measurement Range Resolution Accuracy
Soil Moisture 0 ~ 100.0 % 0.1% ± ( 5 % F.S.+ 5d )
Thermister temprature
Measurement Range Resolution Accuracy
thermister 0 to 60.0
℃
0.1
℃
± ( 1.5% F.S.+ 5d )
temperation.
* F.S. = Full Scale
@ Above specification tests under the environment RF Field Strength
less than 3 V/M & frequency less than 30 MHz only.
4

3. FRONT PANEL DESCRIPTION
F
ig. 1
3-1 Display 3-13 Reset Button
3-2 Power Button ( Backlight Button ) 3-14 DC 9V Power Adapter Input Socket
3-3 Hold Button 3-15 Battery Compartment/Cover
3-4 REC Button 3-16 Battery Cover Screws
3-5 ▲ Button 3-17 Stand
3-6 ▼ Button 3-18 Tripod Fix Nut
3-7 SET Button ( Clock Button ) 3-19 Probe Plug
3-8 LOG Button ( ENTER Button ) 3-20 Probe Handle
3-9 Probe input socket 3-21 Soil moisture/Temp. sensiong
3-10 Probe 4 pin protective
3-11 SD card socket
3-12 RS-232 Output Terminal
5

4. MEASURING PROCEDURE
4-1 Soil moisture/temp. Measurement
1) Power on the meter by pressing the " Power button "
( 3-2, Fig. 1 ) > 3 seconds continuously.
* After already power on the meter, pressing the
" Power button " > 3 seconds continuously will
turn off the meter.
2) Install the " Probe Plug " ( 3-19, Fig. 1 ) into the
" Probe Input Socket " ( 3-9, Fig. 1 ).
3) When Power on the meter, the meter display will show the
" % " ( moisture ) & "
℃
" ( temp. ) unit Now the meter is ready
for make the measurement.
4) Use the hand to hold the " Sensor Handle " ( 3-20 ), sensor test
stainles 4pin " soil Sensor " ( 3-21, Fig. 1 ) into soil about 4 cm
to measurement soil moisture & temp., The display will show the
soil measurement value.
Remark :
*If want to chang the Temp. unit (
℃
or
℉
)
please refer chapter 7-7 ( page 17 ).
* if finish the measurement please clean stainless test pin
and use the protective unit to protec the stainlesstest pin.
6

4-2 Data Hold
During the measurement, press the " Hold Button " ( 3-3,
Fig. 1 ) once will hold the measured value & the LCD will
display a " HOLD " symbol.
Press the " Hold Button " once again will release the data
hold function.
4-3 Data Record ( Max., Min. reading )
1) The data record function records the maximum and
minimum readings. Press the " MAX/MIN Button " (
3-4, Fig. 1 ) once to start the Data Record function and
there will be a " REC " symbol on the display.
2) With the " REC " symbol on the display :
a) Press the " MAX/MIN Button " ( 3-4, Fig. 1 ) once, the
" REC MAX " symbol along with the maximum value
will appear on the display.
b) Press the " MAX/MIN Button " ( 3-4, Fig. 1 ) again, the
" REC MIN " symbol along with the minimum value
will appear on the display.
c) Press the " MAX/MIN Button " ( 3-4, Fig. 1 ) again,
the " MIN " symbol will be disappeared, LCD only
show the " REC " symbol, the meter start the Data
Record function again.
3) To exit the memory record function, just press the "
MAX/MIN Button " ( 3-4, Fig. 1 ) > 3
seconds
continuously. The display will revert to the current
reading.
4-4 LCD Backlight ON/OFF
1) After power ON, the " LCD Backlight " will light
automatically. During the measurement, Push the "
Backlight Button " ( 3-2, Fig. 1 ) once , will turn OFF the
" LCD Backlight ".
2) Push the " Backlight Button " once will turn ON the " LCD Backlight "
again.
7

5. DATALOGGER
5-1 Preparation before execute datalogger function
a. Insert the SD card
Prepare a " SD memory card " ( 1 G to 16 G, optional ),
insert the SD card into the " SD card socket " ( 3-11, Fig. 1).
The front panel of the SD card should face against the
the down case.
b. SD card Format
If SD card just the first time use into the meter, it
recommend to make the " SD card Format " at first. ,
please refer chapter 7-6 ( page 16 ).
c. Time setting
If the meter is used at first time, it should to adjust the
clock time exactly, please refer chapter 7-1 ( page 14 ).
d. Decimal format setting
The numerical data structure of SD card is
default used the " . " as the decimal, for
example "20.6" "1000.53" . But in certain
countries ( Europe ...) is used the " , " as the
decimal point, for example " 20, 6 "
"1000,53". Under such situation, it should
change the Decimal character at first, details
of setting the Decimal point, refer to Chapter
7-5, page 1
6.
8
Table of contents
Other MRC Measuring Instrument manuals