Magneti Marelli Smart Gas User manual

1161306-0 22
Quick Start
Smart Gas –Logic Gas
Gas analyzer
Operating manual
(ENGLISH)
Rev 2.0

1161306-0 23
Summary
1 Package contents ________________________________________ 24
2 Warranty ________________________________________________ 25
2.1 Warranty Coverage .................................................................... 25
2.2 Repair & Replacement ............................................................... 25
2.3 Remedy ..................................................................................... 26
2.4 Warranty Excl sions .................................................................. 26
3 Product installation _______________________________________ 27
3.1 Power s pply ............................................................................. 27
3.2 F nction keys ............................................................................. 28
3.3 Gas probe connection ................................................................ 28
3.4 Probe connection: temperat re and rpm .................................... 29
4 Gas analyzer use _________________________________________ 2
4.1 Free page ____________________________________________ 30
4.2 Light test and gas official proced re _______________________ 31
4.2.1 Preliminary steps .................................................................... 31
4.2.2 Test start ................................................................................ 31
4.2.3 HC test ................................................................................... 32
4.2.4 Leak test ................................................................................. 32
4.2.5 Test exec tion ........................................................................ 32
4.2.6 Print report.............................................................................. 33
4.3 Analyzer config ration __________________________________ 33
4.3.1 Workshop data set- p ............................................................ 33
4.3.2 Time and date set- p .............................................................. 34
5 Use of the instrument through PC with serial connection ________ 35
6 PC software installation procedure __________________________ 36
7 Software use on PC _______________________________________ 37
8 Using the Bluetooth Pairing module _________________________ 38
Instrument cleaning _______________________________________ 40

1161306-0 24
1 Package contents
Gas analyzer Smart Gas/Logic
Gas
220V s pply cable
Serial cable for connection to the PC
Exha st gas sampling probe
Logbook

1161306-0 25
CD ROM containing instr ment and
Dir mod les ser man al
WARNING
This man al provides all necessary information to install the
prod ct in a few steps, and to s pport the ser d ring the vehicle
first gas analysis.
For f rther information, also concerning merely technical iss es, please refer
to the 1161061-0 ser man al contained in the s pplied CD, where yo can
find more detailed information on the themes that are shortly handled in this
doc ment.
2 Warranty
2.1 Warranty Coverage
Magneti Marelli After Market Parts and Services (MM AM P&S) warrants the
Prod ct for 24 (Twenty fo r) Months starting from the date of the Prod ct’s
activation or the date of the original p rchase t rning o t by the P rchase
Doc ments. Any operation performed nder the Warranty Period, doesn’t
extend the Expiry date of the Warranty.
2.2 Repair & Replacement
The Warranty incl des the Repairing or Replacement of the original
Components which ,by the nchangeable sentence of MM AM P&S, came
o t fa lty from the Man fact rer, ca se man fact re defects or flaw material.
The Warranty doesn’t incl de the complete Eq ipment.
The Repairing nder Warranty is being carried close the Service Assistance
Department indicated by MM AM P&S.

1161306-0 26
The Warranty excl des the repairing close the C stomer.
The Service Assistance Department doesn’t g arantee any Repairing Time,
b t is engaged to repair the Eq ipment as soon as possible.
2.3 Remedy
To take advantage of the Warranty, the C stomer has to send the Prod ct in
‘Carriage Paid Shipment’ to the Service Assistance Department indicated by
MM AM P&S, as soon the problem has been forwarded to the Service
Assistance Department.
The Prod ct m st to be packed properly and safely, in order to avoid possibly
damages d ring the transport.
MM AM P&S shall not be nder liability in respect of possible damages
arising from the transport.
The Prod ct sent nder Warranty m st to be provided by the copy of the
P rchase Doc ment.
The Prod ct will be ret rned back to the C stomer in ‘Carriage Forward
Shipment’.
2.4 Warranty Exclusions
The Warranty does not extend to degraded Parts ca sed by the wrong sing
of the Eq ipment d e to working condition o t of the Technical Specifications.
The Warranty will be not extended to Prod ct in the following cases:
• Transport Damages d e to the inappropriate package
• Wrong se of the Prod ct
• Th nderbolt, Tempest, Explosion, Flood, Fire
• Inappropriate Installation or Maintenance
• Mechanical Damages
• Set p carried o t by a non-a thorized Personnel
• Repairing and Replacement or prod ct Modification carried o t by a
non-a thorized Personnel
• Use of not original Parts
• Damages d e to H midity, D st, Power S pply Leakage or High
Voltage, and any others abnormal conditions
• Eq ipment se into inappropriate places
• Any kind of Display damages
• Any kind of Action or Event not attrib table to the MM AM P&S S.p.A
liability

1161306-0 27
In case of the Prod ct sent for Repairing is not nder Warranty, the C stomer
will be advised and will have to a thorized the Repairing o t-of-Warranty.
The cost of the Repairing will be charged to the C stomer.
In case of nj stified demand of Warranty, the labor cost for checking and
verifying the Prod ct will be charged to the C stomer.
3 Product installation
Take the instrument out of the package and follow the procedure to
carry out a vehicle first exhaust gas analysis in ten minutes.
3.1 Power supply
The device shall be powered thro gh the network cable s pplied with the
package.
Insert the s pply cable in the o tlet placed in the instr ment rear side, as
shown in the pict re below.
T rn on the instr ment by p shing the rocker switch near the o tlet.

1161306-0 28
3.2 Function eys
3.3 Gas probe connection
The gas analysis probe feat res a
metallic nozzle collecting the gases,
and shall be inserted in the vehicle
exha st pipe, whereas the other side
shall be connected to the analyzer.
The instr ment gas inlet is sit ated
on the condensate separator.
Connect the gas sampling probe as
shown in the pict re.
Arrow keys to move
in the menus
Function key to gain
access to the set-up
menu, to activate the
numeric writing mode,
capital or small letters
Alphanumeric keys to
enter data

1161306-0 29
3.4 Probe connection: temperature and rpm
The ports where to connect the
probes (option) are placed on the
instr ment rear side.
In partic lar, the D-s b connector
marked with the symbol “°C” shall be
sed to connect the temperat re
probe, whereas the "RPM" marked
one for connecting the rev co nter
with pliers or the M.C.T.C.NET one of
the rs232 type.
4 Gas analyzer use
Upon analyzer Smart Gas switch on the display will show a short introd ction
message, then the analyzer enters a tomatically in the main page where it is
possible to select the type of test to be carried o t.
<Gas analysis>
►Free page
Light Test
Official proc.
From the main selection page it is possible to gain access to the:
- Free page: to read the exha st and engine principal val es (engine
temperat re and rpm).
- Mandatory emission test: for the f el vehicles mandatory emission test.
- Official proced re: to carry o t the test in accordance with the most
recent Standards in matter of gas analysis.

1161306-0 30
4.1 Free page
Press the ENTER key (↵) on the main men to enter in “Free page”.
After t rning on the instr ment, the warm p phase begins (“WARM UP”); it is
necessary to wait for the analysis cell to be properly warmed p before going
on with the test. D ring this phase the analyzer p mp is off.
D ring the analyzer warm p, the display will show the wording “Please
wait” and a bar will indicate the operation progress.
The warm p average time is of 3-5 min tes depending on the environment
temperat re.
At the end of the “WARM UP”, the p mp t rns on, and the display shows the
message “Analyzer reset in progress, please wait”.
After abo t 30 seconds the gas val es will appear as shown below:
Example
CO= 0.00 % HC= 0 ppm
CO2= 0.0 % O2= 20.90 %
COc= -.- % λ= -.---
RPM= 0 T= --- C.
Insert the gas sampling probe in the exha st pipe of a f el vehicle to get the
gas analysis in real time.
Wait at least 30 seconds for the gas val es stabilization,
then press ENTER (↵) and PRINT to print the res lts.

1161306-0 31
4.2 Light test and gas official procedure
To carry o t tests in "Official proced re" or for the "Light Test" it is necessary
to se the rpm and temperat re probes.
If, for technical reasons, sho ld it not be possible to se them, it is possible to
man ally enter all data in the analyzer.
4.2.1 Preliminary steps
“Mandatory emission test”: yo will be asked to select the vehicle engine
type, (for any detail on the categories, please refer to page 38 of the ser
man al).
<Gas analysis>
Free page
Light Test
Official proc.
Press the confirmation key (↵).
4.2.2 Test start
If the vehicle has a do ble f el system, the ser shall select the primary and
the secondary f el.
Select the n mber of the exha st pipes.
After having entered all data, the analyzer will carry o t two checking tests of
the pne matic system:
- HC test
- Seal test
This manual suits for next models