M-system AS4M User manual

AS4M
P. 1 / 4EM-1605 Rev.11
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
POTENTIOMETER ALARM
(dual or quad alarm trip; eld-congurable) MODEL AS4M
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner (body + base socket) ...................... (1)
■MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■INSULATION CLASS
•This unit is provided with the class of basic insulation.
Prior to installation, check that the insulation class of this
unit satisfies the system requirements.
■CONFORMITY WITH LOW VOLTAGE DIRECTIVE OR UL
•ThisequipmentissuitableforuseinaPollutionDegree
2 environment and in Installation Category II, with the
maximum operating voltage of 300V.
Basic insulation is maintained between signal input, out-
put and power input. Prior to installation, check that the
insulation class of this unit satisfies the system require-
ments.
•Altitudeupto2000meters
•Theequipmentmustbemountedinsideapanel.
•The equipment must be installed such that appropriate
clearance and creepage distances are maintained to con-
form to CE/UL requirements. Failure to observe these re-
quirements may invalidate the CE/UL conformance.
■CONFORMITY WITH EMC DIRECTIVE
•Insertanoisefilterforthepowersourceconnectedtothe
unit.Densei-LambdaNoiseFilterModelMZS-1206-33or
equivalent is recommended.
•
The actual installation environments such as panel con-
figurations, connected devices, connected wires, may affect
the protection level of this unit when it is integrated in
a panel system. The user may have to review the CE re-
quirements in regard to the whole system and employ ad-
ditional protective measures to ensure the CE conformity.
■POWER INPUT RATING & OPERATIONAL RANGE
•Locatethepowerinputratingmarkedontheproductand
confirm its operational range as indicated below:
100–240VACrating:85–264V,47–66Hz,approx.6VA
(100 – 240V ±10% for UL)
24VDCrating:24V±10%,approx.3.5W
110VDCrating:85–150V,approx.3.5W(110V±10%forUL)
■GENERAL PRECAUTIONS
•Beforeyouremovetheunitfromitsbasesocketormount
it, turn off the power supply and input signal for safety.
■ENVIRONMENT
•Indooruse
•Whenheavydustormetalparticlesarepresentintheair,
install the unit inside proper housing with sufficient ven-
tilation.
•Donotinstalltheunitwhereitissubjectedtocontinuous
vibration.Donotsubjecttheunittophysicalimpact.
•Environmentaltemperature must be within-5to+55°C
(23to131°F)withrelativehumiditywithin30to90%RH
in order to ensure adequate life span and operation.
■WIRING
•Do not install cables (power supply, input and output)
close to noise sources (relay drive cable, high frequency
line, etc.).
•Do not bind these cables together with those in which
noisesarepresent.Donotinstalltheminthesameduct.
■AND ....
•Theunitisdesignedtofunctionassoonaspowerissup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
INSTALLATION
Detachtheyellowclampslocatedatthetopandbottomof
the unit to separate the body from the base socket.
■DIN RAIL MOUNTING
Set the base socket so that its
DINrailadaptorisatthebot-
tom. Position the upper hook
at the rear side of base socket
on the DIN rail and push in
thelower.Whenremovingthe
socket, push down the DIN
railadaptorutilizingaminus
screwdriver and pull.
■WALL MOUNTING
Refer to “EXTERNAL DI-
MENSIONS.”
Body
Specifications
Base Socket
Connection Diagram
Clamp
(top & bottom)
DIN Rail
35mm wide
Spring Loaded
DIN Rail Adaptor
Shape and size of the base socket
are slightly different with various
socket types.

AS4M
P. 2 / 4EM-1605 Rev.11
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
FRONT VIEW & PROGRAMMING
■PROGRAMMING PROCEDURE
1) PressITEMUPorDOWNkeyuntilITEMdisplayindicates“01”.
2) Press DATA UP or DOWN key and choose“1” or“2” on DATA
display.
1 : Only alarm setpoints are modifiable.
2:Allparametersaremodiable.
3) Press ITEM UP or DOWN key until ITEM display shows the
ITEMNo.youneedtochange.
4) PressDATAUPorDOWNkeyandchooseaDATANo.orvalue
youneedonDATAdisplay.
5) Repeatabove3and4.(Entereddataisstoredwhenyoumoveto
a new ITEM.)
6) PressITEMUPorDOWNkeyuntilITEMdisplayindicates“01”.
7) PressDATAUPorDOWNkeyandchoose“0”onthedisplay.
8) PressITEMUPorDOWNkeyuntilITEMdisplayindicates“P”.
DATAdisplayshowsprocessinput.
(YoucannowcheckdatasettingbychoosingITEMNo.)
Note:DONOTpressUPandDOWNkeyssimultaneously.
L1
L2
L3
L4
ALARM
DATA
ITEM
DATA
ITEM
ITEM No. Display
DATA UP-DOWN Keys
ITEM No. UP-DOWN Keys
*Monitor LEDs
DATA Display
*L3 or L4 does not turn on for dual output type.
ITEM
MDF.
CODE
DATA CONTENTS DEFAULT SETTING
PN/A -1999–9999 Processinputdisplayinengineeringunit(assetinITEM07/08) ----
L1
L2
L3
L4
1, 2
1, 2
1, 2
1, 2
-1999–9999*
1
-1999–9999*
1
-1999–9999*
1
-1999–9999*
1
L1 alarm setpoint in engineering unit
L2 alarm setpoint in engineering unit
L3 alarm setpoint in engineering unit *
2
L4 alarm setpoint in engineering unit *
2
Quad:20.0Dual:20.0
Quad:30.0Dual:80.0
Quad:70.0
Quad:80.0
01 0, 1, 2 Modification code
0:Dataindicationonly.
1 : Only ITEM L1 – L4 are modifiable.
2:Allparametersaremodiable.
1
02 N/A 0 Statusindication(“0”isnormallyindicated.)
0:Normal1:Memoryerror10:Outofinputrange-15–115%
03 N/A 5 Input type
5:Potentiometer
04 N/A -15.0–115.0 Inputindicatedin%(assetinITEM27,28) ----
05
06
2
2
-19.99–99.99
0.000–9.999
Zeroadjustment(%)(neadj.ofthevaluesetinITEM27) 0.00
Gainadjustment(neadj.ofthevaluesetinITEM28) 1.000
07
08
2
2
-1999–9999
-1999–9999
Displayrangescaling0%*
3
Displayrangescaling100%*
3
0.0
100.0
09 20, 1, 2, 3 Decimalpoint
position
(Specify the
number of
digits)
0 : _ _ _ _
1 : _ _ _ . _
2 : _ _ . _ _
3 : _ . _ _ _
1
10 2 0–99 PowerON-delaytime(seconds) 5
11 2 0–999 AlarmON-delaytime(seconds) 0
12 2 0, 1, 2, 3, 4 Moving average (sampling cycle: 100 msec.)
0:No,1:4samples,2:8samples,3:16samples,4:32samples
0
13
14
15
16
2
2
2
2
0, 1
0, 1
0, 1
0, 1
L1 trip operation
L2 trip operation
L3 trip operation
L4 trip operation
(0:Lo,1:Hi)
(0:Lo,1:Hi)
(0:Lo,1:Hi)*
2
(0:Lo,1:Hi)*
2
Quad: 0
Quad: 0
Quad: 1
Quad: 1
Dual:0
Dual:1
17 2-1,0,1–60 Power-saving mode
-1 : Continuous display upon startup
0 : Continuous display after the last access
1–60:Timebeforedisplayturnedoff(minutes)
0: Continuous display
18
19
20
21
2
2
2
2
0, 1
0, 1
0, 1
0, 1
L1coilatalarm(0:Energized,1:De-energized)
L2coilatalarm(0:Energized,1:De-energized)
L3coilatalarm(0:Energized,1:De-energized)*
2
L4coilatalarm(0:Energized,1:De-energized)*
2
0
0
0
0
22 N/A ---- VersionNo.indication ----
23
24
25
26
2
2
2
2
1–9999
1–9999
1–9999
1–9999
L1 hysteresis (deadband) in engineering unit
L2 hysteresis (deadband) in engineering unit
L3 hysteresis (deadband) in engineering unit *
2
L4 hysteresis (deadband) in engineering unit *
2
1.0
1.0
1.0
1.0

AS4M
P. 3 / 4EM-1605 Rev.11
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the con-
nection diagram on top of the unit.
U(+)
V(–)
POWER
7
8
10
11
9
2
3
1
L2 OUTPUT
L1 OUTPUT
N.C.
N.O.
COM
N.C.
N.O.
COM
■SPDT RELAY
U(+)
V(–)
POWER
7
8
10
11
9
2
3
1
L4 OUTPUT
L1 OUTPUT
COM
L3 OUTPUT
L2 OUTPUT
COM
■N.O. RELAY ■N.C. RELAY
10
11
9
2
3
1
L4 OUTPUT
L1 OUTPUT
COM
L3 OUTPUT
L2 OUTPUT
COM
4
5
6
4
5
6
+
–
3
2
1
POTENTIOMETER
max.
min.
+
–
3
2
1
POTENTIOMETER
max.
min.
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the terminal
7–8withamultimeter.
3) Input: Check voltage across the terminal 5 (+) – 6 (–)
with a voltmeter to show 0V at 0% potentiometer input
andthesamevoltageasthatacross4(+)–6(–)at100%
input.
4) Alarmoperations:Checkthealarmoperationsreferring
to the figure below.
5) Output load: Check that the output load is 380V
AC/120VA or 125V DC/30W (380V AC/600VA or 125V
DC/150W for dual alarm, Output Code 5) at the maxi-
mum. For maximum relay life with inductive load, ex-
ternal protection is recommended.
050 100
Input
(%)
LL LHHH
L2 (1–2) ON
L3 (1–3) ON
L4 (9–11) ON
OFF
OFF
L1 (9–10) ON
OFF
OFF
Alarm Trip Operation Terminal No. in parentheses
Example with quad N.O. contacts (LL, L, H, HH)
Trip Operation in Power Failure
• Output code 2: All relays turn off.
• Output code 3: All relays turn on.
• Output code 5: Terminals 1 –3, 9 – 11 turn on.
ITEM
MDF.
DATA CONTENTS DEFAULT SETTING
CODE
27 2 0.0–100.0 0%input(%)(ITEM27<ITEM28) 0.0
28 2 0.0–100.0 100%input(%)(ITEM27<ITEM28) 100.0
29 2 0,1 Latchingcontrol (0:Disabled,1:Enabled) 0
Selecting“0”resetslatchingrelays.Turningpowersupplyoff
also resets them.
30 ---- 0000–1111 Alarmindication (0:OFF,1:ON) ----
TheMSDindicatestheL1,whiletheLSDindicatestheL4.
*1. Selectable within the display scaling range
*2. Quad alarm trip type only
*3.OftherangesetinITEM05/06.ITEM07<ITEM08.

AS4M
P. 4 / 4EM-1605 Rev.11
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
MAINTENANCE
Regularcalibrationprocedureisexplainedbelow:
■CALIBRATION
Warmuptheunitforatleast10minutes.
• H (HH) Setpoint
Increase the input signal from a value lower than the set-
pointandcheckthattherelaytripsattheH(orHH)set-
point within the setpoint accuracy described in the data
sheet.
• L (LL) Setpoint
Decreasetheinputsignalfromavaluehigherthantheset-
point and check that the relay trips at the L (or LL) setpoint
within the setpoint accuracy described in the data sheet.
Whenthesetpointsareshifted,pleasecontactM-System’s
Sales Office or representatives.
LIGHTNING SURGE PROTECTION
In order to protect the unit from lightning surges entering
through power supply cables, use of appropriate lightning
surge protectors are recommended. Please contact M-Sys-
tem.
EXTERNAL DIMENSIONS unit: mm (inch)
80 (3.15)
50 (1.97) 103 (4.06)
132 (5.20)
20
(.79)
• When mounting, no extra space is needed between units.
5678
21
1110
[3.3 (.13)]
80 (3.15)
35.4 (1.39)
40 (1.57)
50 (1.97)
7.8 (.31)
CLAMP
(top & bottom)
DIN RAIL
35mm wide
2–4.5 (.18) dia.
MTG HOLE
25 (.98) deep
11–M3.5
SCREW
39
4
Other M-system Measuring Instrument manuals

M-system
M-system 47 Series User manual

M-system
M-system 47DV User manual

M-system
M-system 47LV User manual

M-system
M-system R7K4GUS-G16D4 User manual

M-system
M-system 71VR1 User manual

M-system
M-system 47LV User manual

M-system
M-system 47 Series User manual

M-system
M-system 47LPT User manual

M-system
M-system KSE-x1 User manual

M-system
M-system 47D Series User manual

M-system
M-system R9EWTU User manual

M-system
M-system MXAB User manual

M-system
M-system 48NAVA User manual

M-system
M-system M2EXM User manual

M-system
M-system 47LPA User manual

M-system
M-system R7CWTU User manual

M-system
M-system 47DT User manual

M-system
M-system 47DM User manual

M-system
M-system 48NV User manual

M-system
M-system 47LT User manual