Kobold DAG-M1F User manual

Operating Instructions
for
Digital Indicator and Controller for Panel
Mounting
Model: DAG-M1F

DAG-M1F
page 2 DAG-M1F K05/0123
We don’t accept warranty and liability claims neither upon this publication nor in
case of improper treatment of the described products.
The document may contain technical inaccuracies and typographical errors. The
content will be revised on a regular basis. These changes will be implemented in
later versions. The described products can be improved and changed at any time
without prior notice.
© Copyright
All rights reserved.
1. Contents
1.Contents ........................................................................................................ 2
2.Note .............................................................................................................. 3
3.Instrument Inspection .................................................................................... 3
4.Regulation Use ............................................................................................. 3
5.Brief description ............................................................................................ 4
6.Assembly ...................................................................................................... 5
7.Electrical connection ..................................................................................... 6
8.Function and operation description ............................................................... 8
9.Setting up the device ................................................................................... 10
9.1Switching-on ...................................................................................... 10
9.2Standard parameterization (flat operation level) ................................ 10
9.3Programming interlock “run” .............................................................. 15
9.4Extended parameterization (Professional operation level) ................. 16
10.Reset to factory settings .............................................................................. 30
11.Alarms / Relays ........................................................................................... 31
12.Programmer examples ................................................................................ 33
13.Technical Information .................................................................................. 36
14.Order Codes ............................................................................................... 36
15.Dimensions ................................................................................................. 36
16.Safety advices ............................................................................................. 37
17.Error elimination .......................................................................................... 39
18.Disposal ...................................................................................................... 40
19.EU Declaration of Conformance ................................................................. 41
Manufactured and sold by:
Kobold Messring GmbH
Nordring 22-24
D-65719 Hofheim
Tel.: +49(0)6192-2990
Fax: +49(0)6192-23398
E-Mail: [email protected]
Internet: www.kobold.com

DAG-M1F
DAG-M1F K05/0123 page 3
2. Note
Please read these operating instructions before unpacking and putting the unit into
operation. Follow the instructions precisely as described herein.
The instruction manuals on our website www.kobold.com are always for currently
manufactured version of our products. Due to technical changes, the instruction
manuals available online may not always correspond to the product version you
have purchased. If you need an instruction manual that corresponds to the
purchased product version, you can request it from us free of charge by email
([email protected]) in PDF format, specifying the relevant invoice number and
serial number. If you wish, the operating instructions can also be sent to you by
post in paper form against an applicable postage fee.
Operating instructions, data sheet, approvals and further information via the QR
code on the device or via www.kobold.com
The devices are only to be used, maintained and serviced by persons familiar with
these operating instructions and in accordance with local regulations applying to
Health & Safety and prevention of accidents.
When used in machines, the measuring unit should be used only when the
machines fulfil the EC machinery directive.
3. Instrument Inspection
Instruments are inspected before shipping and sent out in perfect condition.
Should damage to a device be visible, we recommend a thorough inspection of the
delivery packaging. In case of damage, please inform your parcel service /
forwarding agent immediately, since they are responsible for damages during
transit.
Scope of delivery:
The standard delivery includes:
Digital Indicator and Controller for Panel Mounting model: DAG-M1F
4. Regulation Use
Any use of the device, which exceeds the manufacturer’s specification, may
invalidate its warranty. Therefore, any resulting damage is not the responsibility of
the manufacturer. The user assumes all risk for such usage.

DAG-M1F
page 4 DAG-M1F K05/0123
5. Brief description
The panel meter DAG-M1F can evaluate pulses in many different ways and show
the result in the 5-digit LED-display. Available options are: frequency coverage with
optional filters, summate of pulses or display values via the time, detection of a
rotational speed or collection of a position via an incremental encoder. The results
can be monitored via alarm conditions and can be displayed onto the optional
switching point. Furthermore, the results can be freely scaled on an optional analog
output and relayed to a control system. The device can be operated directly by
Namur sensors, 3 wire sensors, switching/ slider contacts, incremental encoders
(HTL-/TTL-output) or TTL-signals. Via the 3 navigation keys on the front, the device
can be adjusted onto different kind of applications and later on different functions
of the device can be controlled. With an individual code, the created
parameterization can be protected against changes of the user.
Numerous applications can be realized with this device, like e.g. tachometer,
revolution counter, flowmeter, dosing equipment, filling capacity meter, baking time
meter of a baking oven, flying knife, position evaluation, position surveillance, flow
rate surveillance, acoustic discharge measurements and so on. By use of the
integrated, configurable functions like permanent min/max-recording, averaging,
frequency filter, setpoint setting, threshold value recording via alarm system, 30-
points-linearisation, mathematic charging and many more, you receive a universal
applicable modern system for your demands in measuring and control technique.

DAG-M1F
DAG-M1F K05/0123 page 5
6. Assembly
Please read the Safety advice on page 37 before installation and keep this user
manual for future reference.
1. After removing the fixing elements, insert the device.
2. Check the seal to make sure it fits securely.
3. Click the fixing elements back into place and tighten the clamping screws by
hand. Then use a screwdriver to tighten them another half a turn.
CAUTION! The torque should not exceed 0.1 Nm!
The dimension symbols can be exchanged before installation via a channel
on the side!

DAG-M1F
page 6 DAG-M1F K05/0123
7. Electrical connection
Type DAG-M1F8 – supply 100-240 VAC DC ± 10%
Type DAG-M1F3 – supply 24 VDC galvanic isolated
Type DAG-M1F30W0R
Frequency 0.01Hz to 9.9999 kHz with speed transmitter / 0 to 2.5000 kHz at
position survey
Attention!
For Namur sensors with a nominal voltage of approx. 8 V, a sensor supply of
12 VDC is needed!

DAG-M1F
DAG-M1F K05/0123 page 7
Connection examples:

DAG-M1F
page 8 DAG-M1F K05/0123
8. Function and operation description
Operation
The operation is divided into three different levels.
Menu level (delivery status)
This level is for the standard settings of the device. Only menu items which are
sufficient to set the device into operation are displayed. To get into the professional
level, run through the menu level and parameterise prof under menu item RUN.
Menu group level (complete function volume)
Suited for complex applications as e.g. linkage of alarms, setpoint treatment,
totaliser function etc. In this level function groups which allow an extended
parameterisation of the standard settings are available. To leave the menu group
level, run through this level and parameterise uloc under menu item RUN.
Parameterisation level
Parameter deposited in the menu item can here be parameterised. Functions, that
can be changed or adjusted, are always signalised by a flashing of the display.
Settings that are made in the parameterisation level are confirmed with [P] and
thus saved. Pressing the navigation keys leads to a break-off the value input and
to a change into the menu level. All adjustments are saved automatically by the
device and changes into operating mode, if no further key operation is done within
the next 10 seconds.

DAG-M1F
DAG-M1F K05/0123 page 9
Function chart:

DAG-M1F
page 10 DAG-M1F K05/0123
9. Setting up the device
9.1 Switching-on
Once the installation is complete, start the device by applying the voltage supply.
Before, check once again that all electrical connections are correct.
Starting sequence
For 1 second during the switching-on progress, the segment test (8 8 8 8 8) is
displayed, followed by an indication of the software type and, after that, also for 1
second, the software version. After the starting sequence, the device switches to
operation / display mode.
9.2 Standard parameterization (flat operation level)
To parameterize, press the [P] key in operating mode for 1 second. The display
then changes to the menu level with the first menu item TYPE.
Table of contents
Other Kobold Measuring Instrument manuals

Kobold
Kobold HPC-S02 User manual

Kobold
Kobold SFL User manual

Kobold
Kobold KFF User manual

Kobold
Kobold DAG-A44 Series User manual

Kobold
Kobold MAK User manual

Kobold
Kobold DAG-A1V User manual

Kobold
Kobold DRH Series User manual

Kobold
Kobold MAS User manual

Kobold
Kobold REG User manual

Kobold
Kobold DF H 3K Series User manual

Kobold
Kobold KEL Series User manual

Kobold
Kobold KME User manual

Kobold
Kobold **C30R Series User manual

Kobold
Kobold KSV User manual

Kobold
Kobold Henschen MAN-SF Series User manual

Kobold
Kobold NMF User manual

Kobold
Kobold NUS-4x04 User manual

Kobold
Kobold OPT-Y24896/0001 User manual

Kobold
Kobold ZUB-MANS-KON1/2 User manual

Kobold
Kobold TUR Series User manual