ISOIL ISOMAG MV110 Operating instructions

MAN_MV110_EN_IT_IS_R13_1.04.XXXX
OPERATING AND MAINTENANCE
MANUAL
MV110

Release number: MAN_MV110_EN_IT_IS_R13_1.04.XXXX
The characters of le name in bold type indicate the software version which the manual refers to; it is visualized at
the instrument start up, or by specic function on DIAGNOSTIC menu.
The reproduction of this manual and any supplied software is strictly forbidden.

MAN_MV110_EN_IT_IS_R13_1.04.XXXX

The manufacturer guarantees only English text available on our web site www.isoil.com
MAN_MV110_EN_IT_IS_R13_1.04.XXXX
1 / 89
INTRODUCTION 3
SAFETY INFORMATION 3
SAFETY CONVENTION 4
TECHNICAL CHARACTERISTICS 5
DIMENSIONS (PLASTIC AND ALUMINIUM VERSIONS) 6
DIMENSIONS (STAINLESS STEEL VERSION) 9
TORQUES 11
MV110 CONSTRUCTION (ALUMINIUM AND PA6 VERSIONS) 13
MV110 CONSTRUCTION (STAINLESS STEEL VERSION) 14
INTERNAL LAYOUT 15
ELECTRICAL CONNECTION AND GROUNDING INSTRUCTIONS 16
INTERNAL LITHIUM BATTERY 17
ELECTRICAL CONNECTION CONVERTER-SENSOR 19
DIGITAL INPUT ON/OFF OPERATION 20
OUTPUTS WIRING 21
RS485 MODBUS MODULE (OPTIONAL) 22
CONNECTORS MIL 23
START VISUALIZATION PAGES 24
MEANING OF FLAGS 26
MEANING OF LED COLORS 26
ACCESS TO THE CONFIGURATION MENU 27
ACCESS VIA MCP INTERFACE (VIRTUAL DISPLAY) 28
FLOW RATE VISUALIZATION 29
QUICK START MENU 29
CONVERTER ACCESS CODE 30
FUNCTIONS MENU 33
FUNCTIONS DESCRIPTION 38
MENU 1 - SENSOR 38
INDEX

The manufacturer guarantees only English text available on our web site www.isoil.com
MAN_MV110_EN_IT_IS_R13_1.04.XXXX
2 / 89
MENU 1 - SENSOR 39
MENU 2 - UNITS 43
MENU 3 - SCALE 45
MENU 4 - MEASURE 47
MENU 5 - ALARMS 49
MENU 6 - INPUTS 50
MENU 7 - OUTPUTS 51
MENU 8 - COMMUNICATION 53
MENU 9 - DISPLAY 54
MENU 10 - DATA LOGGER 55
USING DATA LOGGER BY MCP INTERFACE 57
MENU 11 - FUNCTION 62
MENU 12 - DIAGNOSTIC 63
MENU 13 - SYSTEM 66
MENU 14 - FILE (ONLY MCP) 72
MENU 15 - PROCESS DATA (ONLY MCP) 73
METER DATA 76
OPERATING PROCEDURE TO CHANGE THE CONVERTER BOARD 77
B.I.V. (BUILT-IN VERIFICATOR) 78
SOFTWARE ISOBIV 81
ALARM MESSAGES (CAUSES AND ACTIONS TO BE TAKEN) 82
ERROR CODE TEST SYSTEM OF SENSOR 83
MANUAL REVIEWS 86

The manufacturer guarantees only English text available on our web site www.isoil.com
MAN_MV110_EN_IT_IS_R13_1.04.XXXX
3 / 89
SAFETY INFORMATION
INTRODUCTION
CONVERTER
SENSOR
These operating instructions and description of device functions are provided as part of the scope of supply.
They could be modied without prior notice. The improper use, possible tampering of the instrument or parts of it and substitutions
of any components not original, renders the warranty automatically void.
The ow meter realizes a measure with liquids of conductivity greater than 5µS/cm in closed conduits, and is composed of a
converter (described in this manual) and a sensor (refer to the specic manual).
The converter could be coupled directly on the sensor (compact version) or coupled to the sensor by cable supplied with it (remote
version).
Any use other than described in this manual aects the protection provided by the manufacturer and compromises
the safety of people and the entire measuring system and is, therefore, not permitted. The manufacturer is not liable
for damaged caused by improper or non-designated use.
Transport the measuring device to the measuring point in the original packaging. Do not remove covers or caps until
immediately before installation. In case of cartons packaging it is possible to place one above the other but no more
than three cartons. In case of wooden packaging do not place one above the other.
Disposal of this product or parts of it must be carried out according to the local public or private waste collection
service regulations.
The converter must only be installed, connected and maintained by qualied and authorized specialists (e.g.
electrical technicians) in full compliance with the instructions in this Operating Instruction, the applicable norms, legal
regulations and certicates (depending on the application).
The specialists must have read and understood these Operating Instructions and must follow the instructions it
contains. The Operating Instructions provide detailed information about the converter. If you are unclear on anything
in these Operating Instructions, you must call the ISOIL service department.

The manufacturer guarantees only English text available on our web site www.isoil.com
MAN_MV110_EN_IT_IS_R13_1.04.XXXX
4 / 89
The converter should only be installed after have veried technical data provided in these operating instructions and
on the data plate.
Specialists must take care during installation and use personal protective equipment as provided by any related
security plan or risk assessment.
Never mount or wire the converter while it is connected to the power supply and avoid any liquid contact with the
instrument’s internal components. To connect remove the terminals from the terminal block.
Before connecting the power supply check the functionality of the safety equipment.
Each part of the instrument must be examined or supplied exclusively by the manufacturer or his representative
Repairs may only be performed if a genuine spare parts kit is available and this repair work is expressly permitted.
For the cleaning of the device use only a damp cloth.
If the instrument is used in a another way than the one specied by the manufacturer, the protection provided by the
device may be compromised.
Before starting up the equipment please verify the following:
Power supply voltage must correspond to that specied on the data plate
Electric connections must be completed as described
Ground (earth) connections must be completed as specied
Verify periodically (every 3-4 months):
The power supply cables integrity, wiring and other connected electrical parts
The converter housing integrity
The suitable tightness of the sealing elements
The front panel integrity (display and keyboard)
The mechanical xing of the converter to the pipe or wall stand
DANGER ELECTRIC SHOCK
WARNING
PRECAUTIONS
ATTENTION
SAFETY CONVENTION

The manufacturer guarantees only English text available on our web site www.isoil.com
MAN_MV110_EN_IT_IS_R13_1.04.XXXX
5 / 89
MODEL: Convert Model
S/N: Serial Number of the converter
SUPPLY: Main power supply
Hz: Supply frequency (AC)
POWER: Maximum power consumption
IP: Protection grade
T: Operation temperature
COUPLING: Serial number of sensor coupled
ITEM: Free for user
Power supply
versions
Power supply
voltage
Power supply
frequency
Min
Power Max power
HV 100-240V~ 45-66HZ
1,5 W
(Sensor only)
12 W
(all Loads)
LV
24-36V //
24-36V~ 45-66HZ
LLV 12-48V //
The instrument label contain the following information:
The converter can be installed internally or externally
Altitude: untill 4000m (from -656 to 6560 feet)
Humidity range: 0-100%
If the converter is supplied in compact version (converter over the sensor), consider the ambient temperatures more
restrictive, otherwise refer to the relevant manuals.
* For discontinuous use, a thermostat heat source installation may be necessary.
TECHNICAL CHARACTERISTICS
Electrical Characteristic
Environmental Use Conditions
Data Plate
ATTENTION! The battery will not be charged
outside the below limits :
T board MV110 < 0 °C
T board MV110 > 50 °C
AMBIENT TEMPERATURE
Aluminium Reinf. Nylon
Min* Max Min* Max
°C -20 + 60 -10 + 50
°F -4 +140 +14 +122
Converter classication: class I,
IP67 (where: 6 = totally protected against dust, 7 = Protected against the eects of temporary immersion) /
IP68 (where: 6 = totally protected against dust, 8 = continuous immersion 1.5 m; 1 h)
for aluminum and PA6 housing, installation category (overvoltage) II, rated pollution degree 2.
Voltage variations must not exceed ±10% of the nominal one.
Input/output are insulated
The output 4-20mA (optional) is electrically connected to the ON/OFF outputs and the output power supply (24V ).
Version LV/LLV : inrush current < 20A
Version HV : inrush current < 25A
Note: The devices powered at 24-36 V and 12-48 V must only be powered with power supplies compliant with the
IEC61010 standard

The manufacturer guarantees only English text available on our web site www.isoil.com
MAN_MV110_EN_IT_IS_R13_1.04.XXXX
6 / 89
DIMENSIONS (PLASTIC AND ALUMINIUM VERSIONS)
200
114 164
167
114
180
290
195

The manufacturer guarantees only English text available on our web site www.isoil.com
MAN_MV110_EN_IT_IS_R13_1.04.XXXX
7 / 89
Separate Version
142
28
295
120
Ø7
30
Table of contents
Other ISOIL Measuring Instrument manuals

ISOIL
ISOIL MS 2500 User manual

ISOIL
ISOIL MS501 User manual

ISOIL
ISOIL SBM 150 User manual

ISOIL
ISOIL Isoflux IFX-F100 User manual

ISOIL
ISOIL ISOFLUX IFX-P200 User manual

ISOIL
ISOIL ISOMAG MV800 Operating instructions

ISOIL
ISOIL SBM 75 User manual

ISOIL
ISOIL SBM 32 CF User manual

ISOIL
ISOIL ISOMAG MS5000 User manual