Iskra PNA760 User manual

Table of Contents
User’s Manual 1


Quick Guide
Portable Network Analyzer PNA760 - Quick Guide
i


Table of Contents
Portable Network Analyzer PNA760 - Quick Guide
iii
Table of Contents
Meaning of symbols see page 4!
1
SECURITY ADVICE AND WARNINGS ...................................................................... 1
1.1
Welcome .................................................................................................................................. 1
1.2
ntroduction ............................................................................................................................. 1
1.3
Health and safety .................................................................................................................... 1
1.4
Safety warnings and instructions for use ................................................................................. 1
1.5
Warnings, information and notes regarding designation of the product ................................ 3
2
BASIC DESCRIPTION AND OPERATION OF ANA YZER ............................................ 4
2.1
ntroduction ............................................................................................................................. 4
2.2
Description of the product ....................................................................................................... 5
2.3
Meter functionality .................................................................................................................. 6
3
CONNECTION ........................................................................................................ 9
3.1
ntroduction ............................................................................................................................. 9
3.2
Electric connection ................................................................................................................... 9
3.3
Connection of tariff inputs ..................................................................................................... 12
3.4
Connection of communication ............................................................................................... 12
4
BATTERY REP ACEMENT ..................................................................................... 14
5
MORE DATA........................................................................................................ 16


Security advice and warnings
Portable Network Analyzer PNA760 - Quick Guide
1
1 SECURITY ADVICE AND WARNINGS
1.1 Welcome
Please read this chapter carefully before starting work with a Analy er.
This chapter deals with important information and warnings that should be considered for safe
work with a Analy er.
1.2 Introduction
These instructions for use are written for the PNA 760 Portable Network Analy er (hereinafter
referred to as Analy er).Installation and use of devices also includes work with dangerous currents
and voltages, therefore such work shall be carried out by qualified persons. The ISKRA Sistemi
Company assumes no responsibility in connection with installation and use of the product. If there
is any doubt regarding installation and use of the system in which the instrument is used for
measuring or supervision, please contact a person who is responsible for installation of such
system.
1.3 Health and safety
The purpose of this chapter is to provide a user with information on safe installation and handling
with the product in order to assure its correct use and continuous operation.
We expect that everyone using the product will be familiar with the contents of chapter »Security
Advices and Warnings«.
If equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
1.4 Safety warnings and instructions for use
Check the following before switching on the device:
Nominal voltage,
Supply voltage,
Nominal frequency,
Voltage ratio and phase sequence,
Battery replacement
At meters that are provided with built-in batteries, it is necessary to replace them with a
corresponding type (Varta, type 6032 CR2032 SLF or equivalent). A battery shall be replaced by an
authori ed service. The battery lifetime is approx. 6 years. Instruction on battery replacement is
given in chapter 4: Battery replacement, page 14.

Security advice and warnings
2
Portable Network Analyzer PNA760 - Quick Guide
Warning for the Analyzer connection and disconnection
- Before use, check the Analy er, measuring voltage connection wires and accessories visually
and make sure that there are no visible damages before use. Replace damaged measuring
voltage connection wires and accessories with new ones of the same quality. Use only insulated
current probes, safety measuring voltage connection wires and safety alligator clip terminals
that are equal to those enclosed to the Analy er.
- For earthing the Analy er, use a special input terminal and do not connect live parts.
- Do not connect input voltages that exceed values specified for the Analy er. Maximum
permitted voltage on safety voltage terminals towards ground:
Input L1, L2, L3, N towards GND is 300 V Cat III.
- When mounting flexible current probes and safety measuring voltage connection wires with
safety alligator clip terminals to the measuring object be careful to disconnect power supply on
non-insulated conductors or use corresponding protection equipment (gloves, etc.) If possible,
don't work alone.
- Don't use the Analy er near explosive gasses and vapours.
- Don't insert metal parts in safety connection terminals and connectors.
Waste
It is forbidden to deposit electrical and electronic equipment as municipal waste. The manufacturer
or provider shall take waste electrical and electronic equipment free of charge. The complete
procedure after lifetime should comply with the Directive EZ 2002/96/EG about restriction on the
use of certain ha ardous substances in electrical and electronic equipment or a corresponding Url
118/04.

Security advice and warnings
Portable Network Analyzer PNA760 - Quick Guide
3
1.5 Warnings, information and notes regarding designation of the product
Used symb
ols:
See product documentation..
Double insulation in compliance with the SIST EN 61010−1: 2004
standard.
Functional ground potential.
Note: This symbol is also used for marking a terminal for protective
ground potential if it is used as a part of connection terminal or auxiliary
supply terminals.
Compliance of the product with directive 2002/96/EC, as first priority,
the prevention of waste electrical and electronic equipment (WEEE),
and in addition, the reuse, recycling and other forms of recovery of such
wastes so as to reduce the disposal of waste. It also seeks to improve
the environmental performance of all operators involved in the life
cycle of electrical and electronic equipment
Skladnost i delka evropskimi smernicami CE.
The delivery includes:
₋ PNA 760 Portable Network Analy er
₋ 5 safety measuring voltage connection wires
₋ 5 safety alligator clip terminals
₋ Axxxx flex current clamps
₋ USB cable
₋ Ethernet cable
₋ RS 232 cable
₋ MiQen software on CD
₋ Connection cable
₋ Short instructions for PNA 760
₋ Detailed instructions for use of UMC 760

Basic description and operation of Analyzer
4
Portable Network Analyzer PNA760 - Quick Guide
2 BASIC DESCRIPTION AND OPERATION OF ANA YZER
2.1 Introduction
Description of symbols
In different chapters or tables different symbols may appear in User’s Manual. According to the
position of symbols, they have different meaning.
Chapter
Meaning of each symbol is:
− Function not supported
− Function partially supported (see a note)
− Function completely supported
Positions follow from left to right:
Subchapter
Symbols next to the subchapters indicate accessibility of functions described. Accessibility of
functions is indicated with the following symbols:
− Function accessible via communication (MiQen software)
− Function accessible via an MMC card
− Function accessible via navigation keys on the instrument front side
Tables
Supported functions and measurements are listed in tables for all types. Symbols in tables indicate
support of enabled functions for each type. Additionally a legend is placed below table of used
symbols. Meaning of symbols is:
●
− Function is supported
×
− Function is not supported
○
− Symbol meaning varies and is described in the legend below the table
User information
For all unknown technical words see chapter Glossary on next page.
Table of contents
Other Iskra Measuring Instrument manuals



























