INSTRUMENTYS CB Q1 User manual

Instruction Manual / Data sheet
CB Q1 / CB Q2
V. 1.0
12/2018
GB
CB Q1 / CB Q2 -BA-e-1810

2 CB Q1 / CB Q2 -BA-e-1810
GB
SAUTER CB Q1 / CB Q2
V. 1.0 12/2018
Instruction Manual / Data sheet
Summarize:
1Short description........................................................................................... 3
2Available models............................................................................................ 3
3Introduction.................................................................................................... 3
4Warning notes................................................................................................ 3
5Warranty......................................................................................................... 4
6Detailed specifications.................................................................................. 4
7Wiring.............................................................................................................. 4
8Dimensions in mm......................................................................................... 5
8.1 5 –500kg ................................................................................................................................... 5
8.2 750kg -1500kg........................................................................................................................... 6
9Certificate of Compliance.............................................................................. 6

CB Q1 / CB Q2 -BA-e-1810 3
1 Short description
Stainless steel IP68 (acc. to EN 60529) / IP69K (acc. To ISO 20653)
bending beam load cell
Suitable platform, hopper, bed and other weighing devices in raw
environment
hermetically sealed
Accuracy OIML R60 C3
OIML certificated models 10kg … 500kg
Option on request: EX, Accuracy C6
2 Available models
Capacity
Model
5 kg
CB 5-3Q1
10 kg
CB 10-3Q1
20 kg
CB 20-3Q1
30 kg
CB 30-3Q1
50 kg
CB 50-3Q1
75 kg
CB 75-3Q1
100 kg
CB 100-3Q1
150 kg
CB 150-3Q1
200 kg
CB 200-3Q1
250 kg
CB 250-3Q1
300 kg
CB 300-3Q1
500 kg
CB 500-3Q1
750 kg
CB 750-3Q2
1000 kg
CB 1000-3Q2
1500 kg
CB 1500-3Q2
3 Introduction
Please pay attention to the notes of the operating manual: read these operating
manual carefully before commissioning, even if you already have experience with
SAUTER measuring cells.
After receiving the measuring cell, it should be checked in advance whether no
transport damage has occurred, whether the outer packaging or other parts or even
the article itself has been damaged. If any damage is evident, please inform
SAUTER GmbH immediately.
4 Warning notes
Observe the national accident prevention regulations.
Not correct executed use of the measuring cell can lead to serious injuries, death,
material damage and personal injuries. Use only by trained and experienced people.
Never load more than the max. capacity to a measuring cell. Overloaded measuring
cells no longer have the required accuracy. Overloaded or deformed measuring cells
are no longer allowed to use and must be changed quickly.
Never step under suspended loads.
Always fasten overload- or break security to your construction.
Pay attention to the allowed static and dynamic loads of the used equipment.

4 CB Q1 / CB Q2 -BA-e-1810
Let the measuring cells calibrate at regular intervals.
Only load the measuring cell in its specified load direction. Avoid lateral forces.
Control the measuring cells to deformations and cracks.
Measuring cells with 4-Conductor cable will change their characteristic value when
shortened or extended the cable length.
5 Warranty
The warranty expires at:
Disregard of the specifications of the operating manual
Modification or opening the measuring cell
Overload
Mechanical damages
Damage caused by liquids or media
Natural loss
Not correct installation
6 Detailed specifications
Output sensitivity ( FS )
mV/V
2.0 ± 0.002
Maximum capacity ( Emax )
kg
5, 10, 20, 30, 50, 75, 100, 150, 200, 250,
300, 500, 750, 1000, 1500
Max.number of load cell
intervals
nLC
3000
Ratio of min. LC verification
interval
Y = Emax /
vmin
10000
Combined Error
%FS
≤± 0.017
Minimum dead load
Of Emax
0%
Safe overload
of Emax
150 %
Ultimate overload
of Emax
200 %
Zero balance
of FS
< ± 2.0 %
Excitation, recommended
voltage
V
10 ~ 15
Input resistance
Ω
400 ± 20
Output resistance
Ω
350 ± 3
Insulation resistance
MΩ
≥5000 ( at 50VDC )
Compensated temperature
°C
-10 ~+40
Operating temperature
°C
-30 ~ +70
7 Wiring
Shielded, 6 cable. Shield not connected to element. Cable diameter: Ø4mm.
Standard cable length: 3m
4-wire diagram

CB Q1 / CB Q2 -BA-e-1810 5
Input(+)
Output(-)
Input (-)
Output(+)
Green
White
Black
Red
8 Dimensions in mm
8.1 5 –500kg
This manual suits for next models
16
Table of contents