2
Do not alter, modify or dispose of improperly. Such action may
cause damage accidents and void warranty.
Operate with 0-35℃(32-95℉), 35-38%RH Use outside of this
range may alter operation of the unit.
To clean, gently wipe with a soft cloth.
This unit may become excessively hot when used
continuously for more than 2 hours.
Summary
This LED stroboscope is our latest new technology product,
which use America CREE high power LED lamps and have the
characteristics of wide measurement range, high brightness, long
life time, they can be used any time, any place. With convenient
operation, the build in lithium rechargeable batteries, single use
time is more than 12 hours. This stroboscope is used to measure
the motions of objects, when the strobe flash speed and
highspeed moving objects are in synchronous fast moving
objects and working status of all kinds of gears and rotors during
working. This stroboscope can be widely used in paper,
packaging, printing industries to inspect the high speed printing
process, ink color matching, die cutting, hole punching and and
folding quality. For textile industry, it can be used to detect the
spindle and thread speed on spindle machine and coiling
machine and inspect the working condition and status of the
mechanical knitting, weaving machine and sewing machine.
When used in mechanical manufacturing, industries, it can be
used for the non contact rpm speed measurement and other
mea s urem e nt. Be s ide, i t c an als o b e u sed in a ircra f t
manufacturing, automotive manufacturing, cable and wire
m a nu fa ct u r i ng , m in i n g , s hi p b u i ld in g, s te el , c h e m ic al ,
pharmaceutical, optional, electronic, food-processing and other
industries.
23
4.6.1 LED flashing auto off
The LED flashing will automatically turn off after 2 minutes
of no keypad or dial operation when using battery power.
Flashing will resume with either a dial (rotation) movement or
a keypad operation.
The LED auto shutoff will not occur in External trigger
mode, while a signal is being received by the unit. The LED
flashing will automatically turn off after 2 minutes of no
external pulse input.
4.6.2 Auto off Power off
The unit will automatically power off after 5 minutes of no
keypad or dial operation when using battery power. To resume
operation, press “POWER” key.
The auto power shutoff will not occur in External trigger
mode, while signal is being received by the unit. The power
will automatically turn off after 2 minutes of no external pulse
input.
Operation Expression
Press and
release OR
Press and
release OR
4.6 Power-saving settings