INCRA MITER3000SE OWNER’S MANUAL
©2016 by Taylor Design Group, Inc. All rights reserved. Rev.1.16
Page 3
4. Left or Right of Blade
Your new Miter3000SE fence is factory congured for
use to the left of the blade. If you prefer to use your
Miter3000SE in the right hand miter slot just follow
the steps below.
Loosen the 1/4-20 socket head screw located at the
end of the 23” section of the fence, then slide out the
4” section of fence along with the attached extender
bar. Move the socket head screw, washer and rectan-
gular nut to the hole on the opposite end of the fence.
Slide the extender bar assembly into the end of fence,
capturing the rectangular nut in the T-slot on the ex-
tender bar. The higher numbers on the extender bar
scale should be closest to the saw blade. Loosen the
(2) socket head fasteners that secure the 4” section
of fence and reverse it. Tighten all fasteners, Fig 6.
Slide the scale in the top of the 23” fence out and re-
place with the included reverse reading scales.
TIP: About Your Fence Scales
All INCRA products use overlapping 16” long Lexan
scales. The overlap allows ne-tuning the scale from
one end to the other to agree with the high degree of
accuracy provided by the INCRA saw toothed posi-
tioning racks. As they are slid into the scale slot on the
fence, the ends are overlapped and aligned using the
optical window located at the end of the second scale.
The friction t will keep the scales in place. If you wish,
you can use a small piece of double faced tape at the
overlap to ensure that the scales move together when
changing your zeroed setups for mitering.
5. Adjust Fence Mounting Bracket 90°
to Saw Blade
Loosen the large clamping knob and make sure that
the rear actuator left hand tooth is engaged rmly
with the 0° notch on the 1/2° adjustment plate. Engage
the front actuator tooth with the 0° notch located on
the protractor head, Fig.7. Tighten the front actua-
tor thumbscrew then tighten the large clamping knob.
Using a Phillips head screw driver, loosen the (3)
Phillips head screws that secure the fence-mounting
bracket to the protractor head. Unplug your table
saw, then use a reliable machinist square to set the
fence at 90° to the saw blade, Fig. 8. Tighten the (3)
Phillips head screws.
This one time calibration prepares your INCRA Mi-
ter3000SE for work in either miter slot. Just remem-
ber that the accuracy of the INCRA Miter3000SE at
any subsequent setting is dependent upon the accura-
cy of your initial 90° calibration. Verify this im-
portant calibration with a test cut and ne
tune as necessary.
Fig. 6 Converting Fence for Use on Right Side of Blade
Fig. 7 Lock Front and Rear Actuator to 0°
Fig. 8 Adjust Fence Bracket 90° to Saw Blade
Move fasteners to opposite
end of fence
4” fence
section
Extender
bar
Remove
extender bar
assembly
1/2° adjustment
plate
Loosen (3) Phillips head screws
Rear actuator
left hand tooth
Front actuator tooth
Square
fence to blade
TIP About Your Fence Scales
Overlap scales as you slide into
scale slot
Optical window used
for proper alignment