TOP Transfer Z30A / Z4A
ENGLISH DEUTSCH
Mounting Instructions

TOP Transfer Z30A / Z4A
TABLE OF CONTENTS
2
TABLE OF CONTENTS
1 Safety instructions 3................................................
2 Markings used 5....................................................
2.1 The marking used in this document 5..................................
2.2 The marking on the product 5.........................................
3 Scope of supply 6...................................................
4 Application notes 8.................................................
5 Structure and mode of operation 9....................................
5.1 TOP-Z30A 9........................................................
5.2 TOP-Z4A 10.........................................................
6 Conditions on site 11.................................................
6.1 Ambient temperature 11..............................................
6.2 Moisture and dampness 11............................................
6.3 Air pressure 11......................................................
6.4 Chemical effects 11..................................................
6.5 Load disturbance variables 11.........................................
6.6 Electromagnetic compatibility 11.......................................
7 Mechanical installation 12............................................
7.1 Important precautions during installation 12..............................
7.2 Installation aids for compressive loading 12..............................
7.2.1 Installation diagram for compressive loading 13..........................
7.3 Installation aids for tensile loading 13...................................
8 Electrical connection 21..............................................
8.1 Notes on cabling 21..................................................
8.2 Pin Assignment 21...................................................
8.3 TEDS transducer identification 23......................................
9 Technical data per VDI 2638 and ISO 376 24.............................
9.1 TOP-Z30A 24........................................................
9.2 TOP-Z4A 26.........................................................
10 Dimensions TOP Transfer 28..........................................
10.1 TOP-Z30A and accessories 28.........................................
10.2 TOP-Z4A and accessories 33..........................................

3
TOP Transfer Z30A / Z4A
SAFETY INSTRUCTIONS
1 SAFETY INSTRUCTIONS
Intended use
The force transducers of TOP Transfer types: TOP-Z30A and TOP-Z4A must be used for
force comparison measurements (force transfer). Use for any additional purpose shall be
deemed to be not as intended.
In the interests of safety, the transducer should only be operated as described in the
Mounting Instructions. It is also essential to observe the appropriate legal and safety
regulations for the application concerned during use. The same applies to the use of ac
cessories.
The transducer is not a safety element within the meaning of its use as intended. For safe
and trouble‐free operation, this transducer must not only be correctly transported, stored,
sited and installed but must also be carefully operated and maintained.
General dangers of failing to follow the safety instructions
The force transducers TOP-Z30A and TOP-Z4A are state‐of‐the‐art and failsafe. Trans
ducers can give rise to remaining dangers if they are inappropriately installed and oper
ated by untrained personnel.
Everyone involved with the installation, commissioning, maintenance or repair of a force
transducer must have read and understood the Mounting Instructions and in particular
the technical safety instructions.
Remaining dangers
The scope of supply and performance of the transducer covers only a small area of force
measurement technology. In addition, equipment planners, installers and operators
should plan, implement and respond to the safety engineering considerations of force
measurement technology in such a way as to minimize remaining dangers. Prevailing
regulations must be complied with at all times. There must be reference to the remaining
dangers associated with force measurement technology.
Unauthorized conversions and modifications are prohibited
The transducer must not be modified from the design or safety engineering point of view
except with our express agreement. Any modification shall exclude all liability on our part
for any damage resulting therefrom.
Qualified personnel
These transducers must only be installed by qualified personnel, strictly in accordance
with the specifications in conjunction with the safety requirements and regulations listed
below. It is also essential to observe the appropriate legal and safety regulations for the
application concerned. The same applies to the use of accessories.

TOP Transfer Z30A / Z4A
SAFETY INSTRUCTIONS
4
Qualified personnel means persons entrusted with the installation, assembly, commis
sioning and operation of the product, who possess the appropriate qualifications for their
function.
Conditions at the place of installation
Protect the transducer from moisture and dampness or weather such as rain, snow, etc.
Maintenance
The force transducers TOP-Z30A and TOP-Z4A are maintenance‐free.
Accident prevention
The prevailing accident prevention regulations must be taken into account, even though
the nominal force values in the destructive range are well in excess of the full scale value.

5
TOP Transfer Z30A / Z4A
MARKINGS USED
2 MARKINGS USED
2.1 The marking used in this document
Important instructions for your safety are specifically identified. It is essential to follow
these instructions in order to prevent accidents and damage to property.
Symbol Significance
WARNING This marking warns of a potentially dangerous situ
ation in which failure to comply with safety require
ments can result in death or serious physical injury.
CAUTION This marking warns of a potentially dangerous
situation in which failure to comply with safety
requirements can result in slight or moderate physical
injury.
Notice This marking draws your attention to a situation in
which failure to comply with safety requirements can
lead to damage to property.
Important
This marking draws your attention to important in
formation about the product or about handling the
product.
Tip
This marking indicates application tips or other
information that is useful to you.
Information
This marking draws your attention to information
about the product or about handling the product.
Emphasis
See …
Italics are used to emphasize and highlight text and
identify references to sections, diagrams, or external
documents and files.
uThis marking indicates an action in a procedure
2.2 The marking on the product
The CE mark enables the manufacturer to guarantee that the
product complies with the requirements of the relevant EU direc
tives (the Declaration of Conformity can be found at
https://www.hbm.com/HBMdoc
).

TOP Transfer Z30A / Z4A
SCOPE OF SUPPLY
6
3 SCOPE OF SUPPLY
SForce transducer TOP-Z30A, TOP-Z4A
SOperating instructions TOP Transfer
The TOP Transfer force transducers are only available in conjunction with a DKD
calibration (not included in scope of supply)
SDKD calibration certificate to ISO 376 Order No. K-CAL-FD...
Accessories for TOP-Z30A
SKnuckle eyes ZGW/ZGOW
for 100 N to 1000 N: Order No. 1-U1R/200kg/ZGW
for 2 kN to 10 kN: Order No. 1-U2A/1t/ZGUW
SThrust piece to ISO 376
for 100 N to 1000 N: Order No. 1-EDO3/1kN
for 2 kN to 10 kN: Order No. 1-EDO4/50kN
SLoad button
for 100 N to 1000 N: Order No. 1-U1R/200kg/ZL
for 2 kN to 10 kN: Order No. 3-9202.0140
SZKM tensile force introduction part to ISO 376
for 2 kN to 10 kN: Order No. 1-Z30/10kN/ZKM
STransportation box
for 4 TOP-Z30A force transducer and accessories
Order No. 1-Z30/Box
Accessories for TOP-Z4A
SZKM tensile force introduction part to ISO 376
for 20 kN: Order No. 1-Z4/20kN/ZKM
50 kN: Order No. 1-Z4/50kN/ZKM
100 kN: Order No. 1-Z4/100kN/ZKM
200 kN: Order No. 1-Z4/200kN/ZKM
500 kN: Order No. 1-Z4/500kN/ZKM

7
TOP Transfer Z30A / Z4A
SCOPE OF SUPPLY
SKnuckle eyes ZGUW/ZGOW
for 20 kN: Order No. 1-Z4/20kN/ZGOW
1-Z4/20kN/ZGUW
50 kN: Order No. 1-U2A/2t/ZGOW
1-U2A/2t/ZGUW
100 kN: Order No. 1-Z4/100kN/ZGOW
1-Z4/100kN/ZGUW
200 kN: Order No. 1-U2A/10t/ZGOW
1-U2A/10t/ZGUW
500 kN: Order No. 1-Z4/500kN/ZGOW
1-Z4/500kN/ZGUW
SThrust piece EDO4 to ISO 376
20kN Order No. 1-EDO4/20kN
50kN Order No. 1-EDO4/50kN
100kN Order No. 1-EDO4/100kN
200kN Order No. 1-EDO4/200kN
500kN Order No. 1-EDO4/500kN
Cables/plugs
Description Order no.
Connection cable Kab 139A-6, 6m,with female cable
connector and free ends
1-KAB139A-6
Connector MS3106PEMV mounted on cable D-MS/MONT
15-pole D plug mounted on cable D-15D/MONT
TEDS ready mounted in 15-pole D plug for Z4A D-TEDS/MONT_DB

TOP Transfer Z30A / Z4A
APPLICATION NOTES
8
4 APPLICATION NOTES
Force transducer TOP Transfer
High precision force transducers in the type series TOP-Z30A and TOP-Z4A measure
compressive and tensile forces.
Because they measure static and quasi-static forces with extremely high accuracy and
reproducibility, they must be handled very carefully. Particular care must be taken when
transporting and installing the devices. Dropping or knocking the transducers may cause
permanent damage. It is recommended, as the TOP Transfer force transducers are peak
precision transducers for transfer measurements, that the ambient temperature is main
tained constant in the range of the nominal temperature.
Force transducers TOP-Z30A and TOP-Z4A with DKD certificate
The transducers are by default calibrated in the pressure direction. They can also be DKD
calibrated in the tensile direction on request. However, the transducer should be loaded
and used in one force direction only for high precision measurements.
The technical data lists the permissible limits for mechanical, thermal and electrical
stress. It is essential that these are taken into account when planning the measuring
set‐up, during installation and ultimately during operation.
To achieve optimum measurement results, the transducer must be connected to a highly
accurate amplifier (e.g. DMP40 from HBK).