Global Specialties GNV-101 User manual

User Manual
GNV-101
Sound Level Meter
(with data logging)
Class 2

1 globalspecialties.com
Global Specialties
Table of Contents
Safety..................................................................................................2
Compliance and Certications............................................................3
Features.............................................................................................4
Specications.....................................................................................5
Instrument Description.......................................................................6
Display Functions...............................................................................7
Operating Instructions..................................................................8-10
Power....................................................................................8
Max/Min Hold........................................................................8
Frequency Weighting............................................................8
Battery Replacement and Indicator.......................................9
Calibration.............................................................................9
Measurement......................................................................10
Operating Precautions........................................................10
Data Logging Set-up........................................................................11
USB Interface Software.............................................................12-15
Warranty/Service Information..........................................................16
Installation...........................................................................12
Main Menu..........................................................................12
Graph..................................................................................13
Toolbar.................................................................................13
Zoom...................................................................................14
Datalogger...........................................................................14
Quick Start Tutorial..............................................................15

globalspecialties.com
Global Specialties
2
Safety
To avoid personal injury and/or product damage, review and comply with
the following safety precautions. These precautions apply to both operating
and maintenance personnel and must be followed during all phases of
operation, service, and repair of this probe.
Dry Conditions
Hands, shoes, oor, and work bench must be dry. Avoid making
measurements under humidity, dampness, or other environmental
conditions that might affect safety.
Cleaning
Use a soft cotton cloth lightly moistened with a mild solution of
detergent and water. Do not allow any portion to be submerged
at any time. Dry thoroughly before attempting to make voltage
measurements. Do not use solvents or expose to solvent fumes as
they may cause deterioration or damage
Do not operate:
• In the presence of noxious, corrosive, flammable fumes,
gases, vapors, chemicals, or finely-divided particulates.
• In environments where there is a danger of any liquid being
spilled on the probe.
• In air temperatures exceeding the specified operating
temperatures.
• In atmospheric pressures outside the specified altitude limits or
where the surrounding gas is not air.
© 2018 Global Specialties (a brand of Cal Test Electronics). All rights reserved.
Unauthorized duplication of Global Specialties documentation materials is strictly prohibited.
Customers are permitted to duplicate and distribute Global documentation for internal
educational
purposes only.

3 globalspecialties.com
Global Specialties
Compliance and Certications
CE Compliance
This product meets the essential requirements of the applicable
European Directives as follows:
• 2014/30/EU: Electromagnetic Directive (EMC)
• 2011/65/EU: Restriction of Hazardous Substances
Directive (RoHS)
Safety
This product meets the follow standard(s) of safety for electrical
equipment for measurement, control and laboratory use:
• IEC/EN 61672-1:2013
Disposal
(Applicable in the European Union and other European
countries with separate collection systems). This
product is subject to Directive 2012/19/EU of the
European Parliament and the Council of the European
Union on waste electrical and electronic equipment
(WEEE), and in jurisdictions adopting that Directive, is
marked as being put on the market after August 13,
2005, and should not be disposed of as unsorted
municipal waste. Please utilize your local WEEE
collection facilities in the disposition of this product.
Caution! Refer to the operating instructions.

globalspecialties.com
Global Specialties
4
Features
• Meets IEC 61672-1 Class 2 requirements
• Records up to 64,000 data points
• Recorded data exportable to EXCEL via a USB interface
• Fast and slow time weighting
• 60 dB dynamic range
• A and C frequency weighting
• AC and DC outputs available from standard 3.5 mm coaxial socket for
use with a frequency analyzer, level recorder, FFT analyzer, etc..
• Min/max function
• Battery capacity indicator
• Analog bar graph and digital display
• Manual and auto range functionality
• Tripod mount for long term monitoring
• Includes windscreen, battery and hard carrying case

5 globalspecialties.com
Global Specialties
Specications
Safety Standard Applied IEC 61672-1 Class 2
Operating Limits and Functions
Measuring Level Ranges Low: 30 to 90 dB
Med: 50 to 110 dB
High: 70 to 130 dB
Auto: 30 to 130 db
Sample Rate Fast 125 ms
Slow 1000 ms
Accuracy ± 1.4 dB @ 94 dB, 1 kHz
Dynamic Range 60 dB
Frequency Range 20 Hz to 8 kHz
Frequency Weighting A / C
Microphone 1/2 Inch electret condenser
Data Logging Capacity 64,000 records
Displays
Digital Display 4 Digit display
Resolution: 0.1 dB
Display Update: 0.5 sec
Analog Display 30 Segment bar graph
Resolution: 2 dB
Display Update: 100 ms
Alarm Functions OVER and UNDER alarm functions indicating
when sound level is outside the set range
Electrical Specifications
AC Ouput 1 Vrms at full scale
DC Output 10 mV/dB
Power Supply 4 AAA batteries: NEDA 24A, IEC LR03
Battery Life Approx. 24 hours
External Power Supply 5 VDC (micro USB plug)
Environmental Specifications
Operating Temperature 0 to 40 °C (32 to 104 °F)
Operating Humidity 10 to 90% Relative humidity
Storage Temperature -10 to 60 °C (14 to 140 °F)
Storage Humidity 10 to 75% Relative humidity
Altitude Up to elev. of 2000 meters (~6,500 ft.)
Mechanical Specifications
Dimensions 264 x 63 x 29 mm (10.4 x 2.5 x 1.1”)
Weight Approx. 245g (8.6 oz)
Included Accessories 4 AAA batteries, User manual, windscreen,
carrying case, USB cable

globalspecialties.com
Global Specialties
6
Instrument Description
1. Windscreen
2. LCD display
3. Power button
4. Level range increase
5. Level range decrease
6. “A” or “C” freq. weighting
7. MIN/MAX hold button
8. Time weighting select
9. Microphone
10. AC/DC output terminal
11. USB Interface
12. Tripod mounting screw
13. Battery Cover

7 globalspecialties.com
Global Specialties
Display Functions
REC FULL
FULL
::
::
Symbol
REC
Function
Battery capacity indicator
Auto power off indicator
Maximum/Minimum inidcator
Time weighting indicator
Level range indicator
Bar graph
Date
Level reading
Frequency weighting indicator
Recording datalogger indicator
Memory full indicator
Under-range indicator
Over-range indicator
Function
Battery capacity indicator
Auto power off indicator
Maximum/Minimum inidcator
Time weighting indicator
Level range indicator
Bar graph
Date
Level reading
Frequency weighting indicator
Recording datalogger indicator
Memory full indicator
Under-range indicator
Over-range indicator
Symbol

globalspecialties.com
Global Specialties
8
Operating Instructions
Power
The button turns the sound level meter on with a single push.
Press and hold the same button for 2 seconds to turn off the power.
By default, when the meter is powered on, it is under auto power off
mode. The meter will shut itself down after 30 minutes if no key is
pressed. To disable this, press and hold until the symbol is
no longer visible.
Max/Min Hold
First adjust the meter to the correct level range and sample rate
prior to using this function. Press the button to start the
maximum and minimum measurement mode.
1. Press the button once and “MAX” will display on the
screen. This indicates that the maximum value is being
updated and recorded.
2. Press again and “MIN” will display on the screen. This
indicates that the minimum value is being updated and
recorded.
3. Press once more and “MIN MAX” will blink on the display.
This indicates that both the minimum and maximum values are
being updated and recorded.
Frequency Weighting
A: Weighting for volumes below 50 dB (dBA)
C: Weighting for volumes above 50 dB (dBC)

9 globalspecialties.com
Global Specialties
Battery Replacement and Indicator
Remove the battery cover from the back, and insert four AAA
batteries. The onboard display will indicate when the battery needs
to be replaced.
Calibration
1. First ensure that the device is turned off. Then press and
hold . Next, press the button and release both. The
meter will display a ashing “CAL 94 dB”.
2. Gently insert the microphone housing into the calibrator* as
depicted below.
3. Press or to increase or decrease the number
displayed until it matches the value 94.0 dB
4. Press to nish calibration. To abort the process, press
the button to cancel.
Batteries Good Batteries Partly Depleted Replace Batteries
*GNV-102 sound level callibrator sold separately
Other manuals for GNV-101
1
Table of contents
Other Global Specialties Measuring Instrument manuals

Global Specialties
Global Specialties GNV-720 User manual

Global Specialties
Global Specialties GSK-118 User manual

Global Specialties
Global Specialties PRO-1000 User manual

Global Specialties
Global Specialties LCR-600 User manual

Global Specialties
Global Specialties GNV-101 User manual

Global Specialties
Global Specialties LCR-58 User manual

Global Specialties
Global Specialties GNV-720 User manual

















