FNM alpha SM 230 User manual

1
User Manual
alpha® WSN Wireless Measurement System SM 230
®
alpha WSN SM 230
®
alpha WSN BM 110 ®
alpha WSN BM 120 ®
alpha WSN BM 130
®
alpha WSN SM 230-G ®
alpha WSN RM 300-G
®
alpha WSN RM 300

2
3
Table of contents
Safety precautions .......................................................................... 5
Safety precautions for the base module alpha WSN BM 1x0 ................ 6
Safety precautions for the sensor module alpha WSN SM 230............. 6
Safety precautions for the repeater module alpha WSN RM 300 .......... 6
General instructions........................................................................ 7
General product description........................................................... 8
Application example sensor network...................................................... 8
Modules of the wireless measurement system ..................................... 9
Base module ........................................................................................................9
Sensor module.....................................................................................................9
Repeater module ...............................................................................................10
Description of device-specific features ....................................... 10
Base modules......................................................................................... 10
Functional elements and interfaces..................................................................11
Base module with LAN interfaces alpha WSN BM 110..................................12
Base module with USB interfaces alpha WSN BM 120 .................................13
Base module with WLAN interfaces alpha WSN BM 130 ..............................14
Sensor module ....................................................................................... 15
Functional elements and interfaces..................................................................16
alpha WSN SM 230-G ......................................................................................16
alpha WSN SM 230 ..........................................................................................18
Description of the interfaces.............................................................................18
I2C (optional)....................................................................................................18
SPI (optional)...................................................................................................18
UART (optional) ...............................................................................................19
PT1000 .............................................................................................................19
Analogue In......................................................................................................20
Analogue Out ...................................................................................................20
Digital In ...........................................................................................................20
Digital Out ........................................................................................................20
Repeater module.................................................................................... 20
Functional elements and interfaces..................................................................21
alpha WSN RM 300-G ......................................................................................21
alpha WSN RM 300..........................................................................................21
Putting the units into operation.................................................... 22
Delivery status........................................................................................ 22
Initial state of the base module after connecting ................................. 22
Base module alpha WSN BM 110 .....................................................................22
Base module alpha WSN BM 120 .....................................................................22
Base module alpha WSN BM 130 .....................................................................22

2
3
Table of contents
Initial state of the sensor module after starting .................................. 23
Initial state of the repeater module after starting ................................. 23
Mounting................................................................................................. 24
General instructions ..........................................................................................24
Mounting instructions for the base module alpha WSN BM 1x0 ....................24
Instructions for the operation of the PCB version (SM 230, RM 300).............24
Configuration of the interfaces.............................................................. 25
Setting the RS232 interface or settings at the terminal programme ..............25
Setting the USB interface ..................................................................................28
Automatic USB driver installation...................................................................28
Manual USB driver installation .......................................................................31
Checking the USB driver settings ..................................................................35
Link test USB-Port ...........................................................................................36
Setting the LAN interface ..................................................................................36
Installation of the LAN driver ..........................................................................36
Checking the LAN driver settings...................................................................39
Configuration of the LAN interface.................................................................40
Automatic setting of the IP address ...............................................................41
Manual setting of the IP address....................................................................41
Setting Serial-Port-Profile ...............................................................................42
Further settings of the LAN module ...............................................................42
Setting the WLAN interface ...............................................................................43
Automatic setting of the IP address ...............................................................43
Manual setting of the IP address....................................................................44
Setting Serial-Port-Profile...................................................................... 44
Setting the encoding .......................................................................................45
Further settings of the WLAN module ............................................................45
Searching for modules by means of Discovery-Tool .......................................45
Control software and software interface ..................................... 47
Control software alpha data view.......................................................... 47
Installation of the control software alpha data view ........................................47
Short description of the control software alpha data view..............................47
Sensor dialogue.................................................................................................48
Setting the sensor parameters..........................................................................49
Selecting alarm criteria for all sensors.............................................................50
Software interface .................................................................................. 50
Protocol description ..........................................................................................50
Messages from the base module to the PC ...................................................51
Messages from the PC to the base module ...................................................51
Overview of commands.....................................................................................52
Description data bytes.......................................................................................54

4
5
Table of contents
Setting the measuring interval .............................................................. 56
Setting the minimum and maximum capacities .............................................57
Login procedure PC at the base module..........................................................59
Login procedure ..............................................................................................60
Logout procedure ............................................................................................61
CRC calculation .................................................................................................62
Maintenance and inspection......................................................... 63
Base module........................................................................................... 63
alpha WSN BM 110, BM 120, BM 130 ...............................................................63
Sensor module ....................................................................................... 63
alpha WSN SM 230-G ........................................................................................63
alpha WSN SM 230 ............................................................................................63
Repeater module.................................................................................... 63
alpha WSN RM 300-G ........................................................................................63
alpha WSN RM 300 ............................................................................................63
Maintenance .................................................................................. 64
Base module alpha WSN BM 1x0.......................................................... 64
Sensor modules alpha WSN SM 230-G and alpha WSN SM 230 ........ 64
Repeater modules alpha WSN RM 300-G and alpha WSN RM 300..... 64
Battery change ....................................................................................... 64
Battery change housing version .......................................................................64
Battery change PCB version .............................................................................65
Troubleshooting ............................................................................ 66
Base module alpha WSN BM 1x0.......................................................... 66
Sensor module alpha WSN SM 230-G and alpha WSN SM 230 .......... 67
Repeater module alpha WSN RM 300-G and alpha WSN RM 300....... 67
Antennas........................................................................................ 67
Technical data................................................................................ 68
General ................................................................................................... 68
Base module........................................................................................... 68
Sensor module ....................................................................................... 69
Repeater module.................................................................................... 69
Declaration of conformity ............................................................. 70
Glossary......................................................................................... 70

4
5
Safety precautions
Attention!
lThe relevant regulations for installation and operation of electrical installa-
tions have to be observed (e. g. RL 1999/92/EG, RL94/9EG, ElexV, IEC/
EN 60 079-14 and VDE 0100).
l The detailed knowledge and the technically correct realization of the installa-
tion guidelines, safety precautions and functions described in this user manual
are essential to the safety of the operation.
l The safety of the product requires an appropriate transport, an appropriate
storage, installation and operation.
l Interference in the product may only be effected by qualified personnel that
is familiar with the user manual.
l When observing the handling instructions and the safety-related instructions,
no dangers regarding damages to properties and to persons come from the
product in normal case.
l Only use the unit for the allowed application. Mind the EC-type examination
certificate.
l Faulty or improper use as well as the noncompliance with the instructions of
this user manual exclude a warranty by the manufacturer.
Safety precautions
ESD protection measures
Comply with the ESD protection measures according
to DIN EN 61340-5-1/2 when opening the unit (potential
equalization between body and ground of the unit as
well as ground of the casing via high-value resistance
(approx. 1 MOhm) e. g. by means of a usual wrist band).

6
7
Safety precautions
The following regulations have to be observed:
• national safety regulations
• national rules for the prevention of accidents
• national regulations for mounting and installation
• generally approved rules of the technique
• safety precautions of this user manual
• characteristic values and measuring operating conditions of the type and data
plates
• additional signboards on the unit
Avoid to touch conductive parts of the unit.
Do not open the unit, only permit repairs by the manufacturer.
Mind the valid legal provisions for the protection of persons in electromagnetic
fields when installing the antenna.
Safety precautions for the base module alpha WSN BM 1x0
Do not use or install the unit in rooms with explosive materials.
Only use an unshielded Twisted Pair cable (UTP) when connecting the LAN interface
of the alpha WSN BM 110!
Do not cover the base module.
Safety precautions for the sensor module alpha WSN SM 230
Do not use or install the unit in rooms with explosive materials.
In case a battery is inserted, no power supply unit may be connected and the battery
has to be removed in case of operation with the power supply unit.
Safety precautions for the repeater module alpha WSN RM 300
Do not use or install the unit in rooms with explosive materials.
In case a battery is inserted, no power supply unit may be connected and the battery
has to be removed in case of operation with the power supply unit.

6
7
Instructions
General instructions
The wireless measurement system can be operated in countries of the European Union
(EU). Outside the EU, the national regulations of the respective country apply. Only use
antennas that are designated for the frequency range, since otherwise, the operating
license expires and you have to expect appropriate sanctions.
Damages to devices or people that are caused due to the use of our units during
malfunction or normal operation according to our documentation or instructions in any
form, are explicitly excluded from liability.
As well excluded are recourse receivables that can occur indirectly or directly because of
the fault of the manufacturer (delay in delivery, malfunctions that can occur in the period of
guarantee etc.).
Each customer has the opportunity to obtain test units for a system integration test.
The test units are in function equivalent to the standard set (except the standard sets
have better features due to state of the art). The customer has to meet the costs for all
necessary adaptations (software as well as hardware). This is particularly applicable in
case the customer did not make use of a test unit.
Furthermore, our general terms and conditions apply.
Read the user manual carefully to be able to use the wealth of features of your new
Wireless Measurement System.
Information regarding the used trademarks
Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. All
other trade and product names are trademarks or registered trademarks of the respec-
tive companies.

8
9
Product description
General product description
In connection with a base module alpha WSN BM 1x0, the sensor module
alpha WSN SM 230 forms a universal wireless network for the sensor data
acquisition. If required, repeaters (alpha WSN RM 300 or alpha WSN RM 300-G) can
be used for the extension of the range.
The sensor module alpha WSN SM 230 has different interfaces for the connection of
many different sensors or signals and may also be used as repeater module itself.
Recorded measured values are cyclically transmitted to the base module by radio.
This base module is linked with a PC or IP network by means of different interfaces,
depending on the type of base module.
For displaying the measured values and events and the setting of the parameters the
sensor modules, the PC software alpha data view is available.
Application example sensor network
Fig.: Example sensor network

8
9
Product description
The sensor data acquisition is often connected with much installation work (laying of a
multitude of cables in areas that are often impracticable and separated) and / or high
personnel expenditure (manual reading of single sensors, interpretation of the measur-
ing results regarding exceeding of the limit etc.). In both cases, considerable financial
expenses arise.
A reasonably priced, flexible alternative that can be adapted to special requirements is
the sensor network alpha WSN from FMN.
Depending on the measuring interval, a total of up to several hundred measuring points is
possible. In order to be able to achieve a sufficient coverage or a higher range, repeaters
can be used. They extend the range of the wireless measurement system by far.
Modules of the wireless measurement system
Base module
The base module receives the transmitted data of the sensor modules and transfers
these over a RS232, USB, LAN or WLAN interface to a PC or an IP network.
The RS232 interface is available at all module versions.
The LAN or WLAN interfaces make the connection to an Intranet or to the Internet
possible and therewith the worldwide inquiry of the measurement data.
At the combination LAN / RS232 (alpha WSN BM 110), the voltage supply will be realized
over an external pluggable power supply unit or over the LAN connection (PoE – Power
over Ethernet) if an appropriate PoE voltage supply is installed in the LAN.
At the combination USB / RS232 (alpha WSN BM 120), it is possible to realize the voltage
supply over the USB interface. Alternatively, the voltage supply can also be realized
over a power supply unit.
At the combination WLAN / RS232 (alpha WSN BM 130), the voltage supply has to be
realized over an external power supply unit.
Sensor module
The sensor module is for the connection of different sensors.
The acquired data is transmitted to the base module by radio and from there, it is
transferred to a PC.
An inquiry as well as setting of the parameters of the sensor modules from base module
(polling) is also possible.
The voltage supply is realised over an internal 3.6 V battery (lithiumthionylchloride,
size 2/3 A). In case the battery voltage is falling below the minimum battery voltage, a
message is sent to the base station. The battery should be changed then. An intelligent
power management guarantees a long battery lifetime.

10
11
Description of device-specific features
Repeater module
The repeater module is for the transmission of the sensor data to the base module. It is
used in case of difficult radio propagation conditions or in case the distances between
sensor and base module are too great.
The voltage supply is realized via an external power supply unit.
A voltage supply over an internal 3.6 V battery (lithiumthionylchloride, size LR14) is
possible, but it is not recommended because of the higher power demand of the re-
peater module.
All versions of the repeater module alpha WSN RM 300 can be used. But a configuration
of the sensor module alpha WSN SM 230 to repeater operation is also possible.
Description of device-specific features
Base modules
The base modules of the sensor network are the interface to the PC network or the IP
network. They receive the data of the single sensor modules and transfer them to a PC.
Connections over RS232, USB, LAN or WLAN are available for this.
The base module can temporarily store up to approx. 45,000 sensor data sets. In case of a
temporary termination of the visualization software or switching off of the PC, the sensor
data is so buffered and is not lost. After starting the visualization software again, the
data is transmitted to the PC.
Furthermore, the base module is equipped with two potential-free outputs (change-over
contacts) that can be controlled from the PC, if required (alarm signalling).
There are two LEDs at every base module. The green LED indicates the operation of the
module (glowing when the module is active) and the red LED indicates correctly trans-
mitted and received packets of data.
Status LED (red) glowing for approx. 50 ms: packet of data transmitted correctly
Status LED (red) glowing for approx. 500 ms: packet of data received correctly
Table of contents