FLIR CM275 User manual

www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

FLIR CM275 USER MANUAL Document Identifier: CM275-en-US_AC
2
Table of Contents
1. ADVISORIES 5
1.1 Copyright 5
1.2 Quality Assurance 5
1.3 Documentation 5
1.4 Disposal of Electronic Waste 5
2. SAFETY 6
3. INTRODUCTION 8
3.1 Key Features 8
4. METER DESCRIPTION 9
4.1 Front and Back Meter Descriptions 9
4.2 Function Switch Positions 10
4.3 Function Buttons and Selector/Navigation Pad 10
4.3.1 MODE Button Sequence of Operations 11
4.3.2 Navigation Pad/OK Button 11
4.4 Status Bar Display Icons 11
4.5 Other Display Icons 12
5. METER POWER 13
5.1 Powering the Meter 13
5.2 Auto Power OFF (APO) 13
5.3 Battery Type Selection 13
6. MENU SYSTEM 14
6.1 Using the Menu System 14
6.2 Main Menu Options 14
6.2.1 Image Mode 14
6.2.2 Thermal Settings Menu 14
6.2.3 Gallery Mode 15
6.2.4 Advanced Functions Menu 15
6.2.5 General Settings Menu 15
7. GENERAL SETTINGS 16
7.1 General Settings Navigation 16
7.1.1 Diode SMART/CLASSIC 16
7.1.2 APO (Auto Power OFF) 16
7.1.3 Datalogger Sample Rate 16
7.1.4 Real-time Clock 16
7.1.5 Battery Selection 17
7.1.6 Bluetooth® ON/OFF 17
7.1.7 Button-press tone ON/OFF 17
7.1.8 Language selection 17
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

FLIR CM275 USER MANUAL Document Identifier: CM275-en-US_AC
3
7.1.9 Delete all Datalogger readings 17
7.1.10 Delete all Stored Images 17
7.1.11 View HELP Screen 17
7.1.12 Viewing meter component information 17
8. THERMAL IMAGING 18
8.1 Thermal Imager Basics 18
8.2 Thermal Imager Operation 19
8.3 Thermal Settings Menu (Color Palette, Emissivity, Temperature Units, Laser
Pointer, Crosshairs) 20
8.4 Image Mode Menu 21
8.5 Image Capture 21
8.6 Image Freeze (Data Hold) 21
9. CLAMP METER OPERATION 22
9.1 Auto/Manual Range Mode 22
9.2 Out-of-range Warning (OL) 22
9.3 Data Hold 22
9.4 VFD Mode (Low Pass Filter) 22
9.5 MAX-MIN Mode 23
9.6 DCA Zero Mode 23
9.7 Datalogger 23
9.8 Current and Frequency Measurements 25
9.9 Clamp Adaptor (FLEX) Current and Frequency Measurements 26
9.10 Inrush Current Measurements 27
9.11 Voltage, Lo Z, and Frequency Measurements 28
9.12 Resistance Measurements 29
9.13 Continuity Test 29
9.14 Classic Diode Test 30
9.15 Smart Diode Test 31
9.16 Capacitance Measurements 32
10. BLUETOOTH® COMMUNICATION 33
11. APPENDICES 34
11.1 Emissivity Factors for Common Materials 34
11.2 Non-Uniformity Correction 34
11.3 Infrared Energy and Thermal Imaging Overview 35
12. MAINTENANCE 36
12.1 Cleaning and Storage 36
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

FLIR CM275 USER MANUAL Document Identifier: CM275-en-US_AC
4
12.2 Battery Replacement 36
12.3 Disposal of Electronic Waste 36
13. SPECIFICATIONS 37
13.1 General specifications 37
13.2 Thermal Imaging Specifications 38
13.3 Electrical Specifications 39
14. TECHNICAL SUPPORT 43
15. WARRANTY 44
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

FLIR CM275 USER MANUAL Document Identifier: CM275-en-US_AC
5
1. Advisories
1.1 Copyright
© 2020, FLIR Systems, Inc. All rights reserved worldwide. No parts of the software
including source code may be reproduced, transmitted, transcribed or translated into
any language or computer language in any form or by any means, electronic, magnetic,
optical, manual or otherwise, without the prior written permission of FLIR Systems.
The documentation must not, in whole or part, be copied, photocopied, reproduced,
translated or transmitted to any electronic medium or machine-readable form without
prior consent, in writing, from FLIR Systems.
Names and marks appearing on the products herein are either registered trademarks or
trademarks of FLIR Systems and/or its subsidiaries. All other trademarks, trade names or
company names referenced herein are used for identification only and are the property
of their respective owners.
1.2 Quality Assurance
The Quality Management System under which these products are developed and
manufactured has been certified in accordance with the ISO 9001 standard.
FLIR Systems is committed to a policy of continuous development; therefore, we reserve
the right to make changes and improvements on any of the products without prior
notice.
1.3 Documentation
To access the latest manuals and notifications, go to the Download tab at:
area you will also find the latest releases of manuals for our other products, as well as
manuals for our historical and obsolete products.
1.4 Disposal of Electronic Waste
As with most electronic products, this equipment must be disposed of in an
environmentally friendly way, and in accordance with existing regulations for
electronic waste.
Please contact your FLIR Systems representative for more details.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

FLIR CM275 USER MANUAL Document Identifier: CM275-en-US_AC
6
2. Safety
Safety Notes
Before operating the device, you must read, understand, and follow all instructions,
dangers, warnings, cautions, and notes.
FLIR Systems reserves the right to discontinue models, parts or accessories, and other
items, or to change specifications at any time without prior notice.
Remove the batteries if the device is to be stored for an extended period.
Warning Statements
Do not operate the device if you do not have the correct knowledge. Incorrect operation
of the device can cause damage, shock, injury or death to persons.
Do not start a measuring procedure before you have set the function switch to the
correct position. Failure to do so can cause damage to the instrument and can cause
injury to persons.
Do not change to the resistance mode when measuring voltage. This can cause damage
to the instrument and can cause injury to persons.
Do not measure the current on a circuit when the voltage increases to more than 1000 V.
This can cause damage to the instrument and can cause injury to persons.
You must disconnect the test leads from the circuit under test before you change the
range. Failure to observe this warning can damage the instrument and cause bodily
injury.
Do not replace the batteries before you remove the test leads. This can cause damage to
the instrument and can cause injury to persons.
Do not use the device if the test leads and/or the device show signs of damage. Injury to
persons can occur.
Be careful performing measurements if the voltages are > 25 VAC rms or 35 VDC. There is
a risk of shock from these voltages. Injury to persons can occur.
Do not do diode, resistance or continuity tests before you have removed the power from
capacitors and other devices under test. Injury to persons can occur.
Be careful when performing voltage checks on electrical outlets. These checks are
difficult because of the uncertainty of the connection to the recessed electrical contacts.
You must not rely solely on this this device when determining if the terminals are not
Do not touch expired/damaged batteries without gloves. Injury to persons can occur.
Do not cause a short circuit of the batteries. This can cause damage to the instrument
and can cause injury to persons.
Do not put the batteries into a fire. Injury to persons can occur.
Use extreme caution when the laser pointer is on.
Do not point the beam toward anyone's eye or allow the beam to strike the eye from a
reflective surface.
Do not use the laser near explosive gases or in other potentially explosive areas.
Refer to the CAUTION statement label (shown below) for critical safety information.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

FLIR CM275 USER MANUAL Document Identifier: CM275-en-US_AC
7
Fig. 2.1 Laser Safety Information
Cautions
Do not use the device in a manner not specified by the manufacturer. This can cause damage to
the protection provided.
This symbol, adjacent to another symbol or terminal, indicates that the user
must refer to the user manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous
voltages may be present.
Double insulation.
UL listing is not an indication or a verification of the accuracy of the meter
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

FLIR CM275 USER MANUAL Document Identifier: CM275-en-US_AC
8
3. Introduction
Thank you for selecting the FLIR CM275 Imaging Clamp meter with IGMTM (Infrared
Guided Measurement) and Bluetooth®. The CM275 is a True RMS 600A AC/DC clamp
meter with a radiometric Lepton Thermal Imaging system, integrated VFD Mode, Inrush
Current capture, , Bluetooth®
communications capabilities, and many others as listed in the Key Features section
below. This device is shipped fully tested and calibrated and, with proper use, will
provide years of reliable service.
3.1 Key Features
6000 count digital TFT display with bargraph
Built-in Infrared Imager with gallery mode for storing, viewing, and transmitting images via
Bluetooth®
Capture fully radiometric thermal images where a temperature measurement is saved for
each display pixel
Imager features Laser pointer, cross hairs targeting, and an intuitive menu system
High power work lights built-in
Auto Range True RMS AC/DC 600 A capability
Auto Range True RMS AC/DC 1000 V capability
Frequency AC bandwidth (45-400Hz)
Frequency Measurements to 60KHz
Flex clamp adaptor input for FLIR TA72_TA74 and other clamp adaptors
Input over-voltage warning
Automatic Datalogger memory (40,000 readings over 10 sets) with selectable sample rate and
Bluetooth® transmission capability
Resistance and Continuity measurements
Capacitance and Diode measurements
Data HOLD
Inrush current
DCA zero function
Low Z (Impedance) mode
Minimum/Maximum memory
Integrated VFD mode (Low-pass filter)
Auto power off (can be disabled or preset to 1, 2, 5, or 10 minutes)
Easy-access battery cover mechanism
Optional FLIR TA04 battery charging system
Micro USB port (battery compartment) for transferring images/data logs to PC; operates
similarly to a conventional thumb drive
Safety Category Rating: CAT IV-600V, CAT III-1000V
Equipped with batteries, test leads, carry pouch, and Quick Start booklet.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

FLIR CM275 USER MANUAL Document Identifier: CM275-en-US_AC
9
4. Meter Description
4.1 Front and Back Meter Descriptions
Fig. 4-1 Front View
1. Jaw opening trigger
2. Navigation Pad/OK button
3. MODE button
4. RANGE button
5. Data Hold (short press)/Work Light (long
press)
6. Rotary function switch
7. COM (negative -) Probe Input jack
8. Positive (+) Probe Input jack
9. Image Save button (short press)
10. Return/Exit button
11. IGMTM button (short press)
12. Color TFT Display
13. Clamp jaw
14. Work lights
15. Laser pointer lens
16. Thermal Imaging lens
17. Tripod mount
18. Battery compartment (micro USB port)
19. Battery compartment lock/unlock
Fig. 4-2 Rear View
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
Other manuals for CM275
1
This manual suits for next models
1
Table of contents
Other FLIR Measuring Instrument manuals

FLIR
FLIR Extech Instruments RH520A-240 User manual

FLIR
FLIR Extech Instruments Oyster-10 User manual

FLIR
FLIR MR04 User manual

FLIR
FLIR MR59 User manual

FLIR
FLIR MR59 Operator's manual

FLIR
FLIR EXTECH HDV-WTX2 User manual

FLIR
FLIR CM42 User manual

FLIR
FLIR CM78 User manual

FLIR
FLIR Extech 380947 User manual

FLIR
FLIR ME13552 User manual