FIS OSR-CWDM User manual

Revision A
1/2019
OSR-CWDM Channel Analyzer
Users Guide
© 1/2019 Fiber Instrument Sales Inc.
Fiber Instrument Sales Inc. makes every eort to insure all statements and information for the products referred to in this docu-
ment are accurate and reliable. FIS can not accept any responsibility for errors, omissions or miss statements, nor can they ac-
cept responsibility for any actions taken based on the information demonstrated herein. FIS reserves the right to make changes
of any kind to the product referred to in this document without prior notice.

I
1. Using This Manual………..…………................................….........…………….......……………………………1
2. Safey………..……………......................................................……….……….......…………………...…………2
3. Quick Start Guide..……………….............................................….….…..........................……….……………4
4. Introduction ………….........…….....................................…..………….………………...……….……………..6
5. Preparation for Use ………....…...............................………….…………………………………………...……7
5.1 Inspection
5.2 Identication and Conguration
5.3 Power Requirements
6. Description……………......……….……….…...................................…….………......….....……..…………….8
Front Panel
Top Plate
7. User Interface................................................ ……..............................….....…..……...……….….......….…..9
7.1 Keypad
7.2 Graph Display
7.3 Menu
Display with Menu Open
Icon Descriptions
Help
Bar Graph View
File Management
Settings
Scope
8. Setting Test Parameters…..…………………………......................................…............…………………..…12
8.1 Parameter Settings Screen
8.2 Setting Parameters
View Setting
Measure
Brightness
Pass Range
Table of Contents
Section PAGE

9. Operation..............................………………………………………………......………........…………...………14
9.1 Start-Up
9.2 Connecting Fiber
9.3 Taking Scans
Scanning
Using Stored Congurations
9.4 Viewing Scans
Graph Display
Graph Information
dBm Scale
Channel Scale
Channel Pass Zone
Cursor Data Information
“A” to “B” Cursor Relational Data
Total Power/Tilt Measurements
9.5 Cursor Operation
Set Active Cursor
Cursor Movement
10. File Management …………….…………………………………………….......……..............………………....17
10.1 File Management Display
Main File Management Screen
Conguration and Scope Folder Displays
10.2 Saving Files
Saving Channel Analyzer Files
Saving Scope Files
Saving Congurations
10.3 File Operations
Making Files for Batch Operations
Deleting Files
Rename Files
Compare Files
Upload Files
Section PAGE
II
Table of Contents
(Continued)

11. Video Scope Operation……................................………………..………....................……………………… 20
11.1 Video Scope Display
11.2 Video Scope File/Help Menu
Home
Quick Save
Quick Load
File Management
Help
11.3 Video Scope Operation Menu
Grading Rings Icon
Pass/Fail Label Icon
Brightness Icon
11.4 Video Scope Operation
Video Probe Tips
Viewing/Focusing a Connector
Centering a Connector Image
Pausing Image Scan
Grading Rings
Pass/Fail
Marking Point of Contamination
Exiting Video Scope Operation
11.5 Pass/Fail Contamination Tables
12 Maintenance ……………………………………………….………..………....................……………………… 25
12.1 Battery Replacement.
12.2 Calibration and Verication
12.3 Adapter Replacement
13. Specications …………………….………….……………………..….……..….............………………………..26
14. Warranty and Repair……………………….………….………………….........….......................……....……...27
14.1 Warranty Information
14.2 Repair Information
15. Trouble Shooting..……….….…………….…………………………............……..............………....................28
16. Version Control………….….…………….…………………………...........……..............………..….…….…..29
III
Section PAGE
Table of Contents
(Continued)

OSR-CWDM Users Guide Revision A 1/2019 1
This Manual contains information for the OSR-CWDM Channel Analyzer. This equipment is touch
screen capable and also has a hard keypad for operation. Note that there are a few operations that
are only accessible with touch screen operation.
This user’s guide is written primarily using the touch screen operation with occasional mention of the
hard key equivalents
There are warnings, cautions and notes as described below displayed throughout this manual. Please
follow all warnings and cautions for your safety and the protection of the equipment.
Warning
A warning alerts to situations that could cause personal injury.
Caution
A caution alerts to situations that may cause damage to the equipment or produce poor testing
conditions resulting in inaccurate test results.
Note
A special annotation that will assist the user with operational features.
Section 1 Using This Manual

2OSR-CWDM Users Guide Revision A 1/2019
This product has been designed and tested in accordance with the Manufacturer’s safety standards, and has
been supplied in a safe condition.
Below are warnings that must be followed by the user to ensure safe operation and to maintain the product in
a safe condition. Failure to follow these safety warnings, can result in damage to the instrument or harm to the
user.
Warning
Personnel should always be aware when working with ber optic test equipment that active
bers may be present and therefore infrared optical energy may be present.
Warning
Never look directly into the end of a connected ber optic cable or ber optic adapter of test
equipment, to do so could expose the user to laser radiation and could result in sever personal
injury.
Warning
To Prevent Fire or Shock Hazard:
Section 3 of this manual is a quick start guide. Prior to using the quick start guide or operating
the equipment in any way, it is highly suggested the user reads all safety information.
Section 2 Safety
Do not install battery types other than those specied by the manufacturer¾
Do not use the charger without the batteries installed ¾
Do not expose the battery charger to rain or excessive moisture¾
Do not use the AC adapter when there are signs of damage to the enclosure or cord¾
Ensure that you are using the correct charger for the local line voltage ¾
Do not use any other charger than the one provided with this instrument.¾

3OSR-CWDM Users Guide Revision A 1/2019
Failure to follow these cautions may damage the equipment and void the warranty.
Caution
The OSR-CWDM is designed for maximum power of +5 dBm per channel and a maximum com-
posite power of +23dBm.
Caution
Fiber-optic connectors are easily contaminated or damaged. The connection to the OSR-
CWDM is a physical contact type of connection and dirty or damaged connectors may impair the
instruments capabilities at minimum and at worst result in the need to return the OSR-CWDM
to the factory for expensive repairs. Prior to making any connection to the unit, ensure that all
proper cleaning procedures have been followed.
Use UPC Finish Connectors Only!
Section 2 Safety

4OSR-CWDM Users Guide Revision A 1/2019
Quick Start Guide
Press to turn on the OSR-CWDM
Caution
Fiber-optic connectors are easily contaminated or damaged. The connection to the OSR-
CWDM is a physical contact type of connection and dirty or damaged connectors may impair the
instruments capabilities at minimum and at worst result in the need to return the OSR-CWDM
to the factory for expensive repairs. Prior to making any connection to the unit, ensure that all
proper cleaning procedures have been followed.
Use UPC Finish Connectors Only!
Section 3 Quick Start Guide
Menu
To enter menu, either press the button or use the stylus to pull the menu up from the bottom of the
screen.
Available icons:
Help displays an on board explanation of features, functions and operations.
Bar graph, touching this icon returns the user to the bar graph.
File icon, touching this icon will brings the user to the le management menu.
Settings icon, touching this icon brings the user to the OSA and general settings menus.
Scope icon, this will opens the video scope feature.
Note
Most features of the OSR-CWDM are accessible with either the touch screen or the hard
buttons on the keypad. This quick start will primarily focus on the touch screen.

5OSR-CWDM Users Guide Revision A 1/2019
Attached the ber to be tested to the optical port.
Scan
Touch the scan indicator or the scan button on the keypad to start the scan.
To stop a scan, touch the scan indicator or press the scan button again.
Cursor Movement/Selection:
To move the cursors touch the screen and the active cursor will snap to that location and moving the stylus up or
down on the display will drag the cursor as desired.
To change the active cursor, touch the red or blue cursor points on the right side of the display. The one outlined
in black is the active cursor. (A/B button on the keypad)
Section 3 Quick Start Guide
Please review the remainder of this user’s guide for full instructions on
using the OSR-CWDM Channel Analyzer
Caution
The OSR-CWDM is designed for maximum power of +5 dBm per channel and a maximum com-
posite power of +23dBm.

6OSR-CWDM Users Guide Revision A 1/2019
The Fiber Instrument Sales Inc., OSR-CWDM Channel Analyzer oers full featured analysis of CWDM
systems in a hand held portable package. CWDM optical levels in CWDM Network, wavelengths
1271nm to 1611nm, may be measured with a resolution of 0.01 dB resolution from -50 to +5 dBm. This
unit has super fast acquisition time of two scans per second. There is a pass/fail feature to assist with
quick evaluation of the scan on the 4 inch color TFT Display. The OSR-CWDM is designed with solid
state optics and no fragile or moving parts to keep the unit eld friendly. There is storage for up to 1000
tests and the test may be viewed and printed with the included CertSoft software for fast and easy
reporting. These units are housed in a rugged enclosure with robust protective boot, are designed to
withstand the rigors of eld use and are extremely user friendly.
Section 4 Introduction
Table of contents
Other FIS Measuring Instrument manuals